SLAC Magnetic Measurements Date: 10-28-2020 Time: 20:48:25 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_015_Cell_47_Upstairs Serial Number: PC33408 Run Number: 5 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement upstairs, cable through switch. Full Set 5 20:48:43 Ambient Measurement Device(s) Being Used, type = None 20:48:43 Magnet Voltage Measurement Device(s) Being Used, type = None 20:48:44 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 20:48:44 XMAG Device(s) Being Used, type = None 20:48:44 Ambient Measurement Device(s) Being Used, type = None 20:48:46   Voltage Measurement, V = 0.000000 V 20:48:47 Temperature Measurement, Probe Number = 0, T = 25.766000 C 20:48:48 Temperature Measurement, Probe Number = 1, T = 26.551000 C 20:48:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.77 P2 = 3458_Meas_Junction, Value = 26.55 20:48:48 Integrated Voltage Measurement... 20:49:15 Voltage Offset Correction: v_off_ini = 0.000003511 V, v_off_fin = 0.000004029 V 20:49:15 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.142795153 Vs 20:49:15 Integrated Voltage Measurement... 20:50:14 Voltage Offset Correction: v_off_ini = 0.000003687 V, v_off_fin = 0.000001842 V 20:50:14 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142745109 Vs 20:50:15   Voltage Measurement, V = 0.000000 V 20:50:16 Temperature Measurement, Probe Number = 0, T = 25.749000 C 20:50:16 Temperature Measurement, Probe Number = 1, T = 26.543000 C 20:50:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.75 P2 = 3458_Meas_Junction, Value = 26.54 20:50:16 Integrated Voltage Measurement... 20:50:48 Voltage Offset Correction: v_off_ini = 0.000002811 V, v_off_fin = 0.000003351 V 20:50:48 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142784800 Vs 20:50:48 Integrated Voltage Measurement... 20:51:19 Voltage Offset Correction: v_off_ini = 0.000004299 V, v_off_fin = 0.000001612 V 20:51:19 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142747463 Vs 20:51:20   Voltage Measurement, V = 0.000000 V 20:51:21 Temperature Measurement, Probe Number = 0, T = 25.766000 C 20:51:22 Temperature Measurement, Probe Number = 1, T = 26.549000 C 20:51:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.77 P2 = 3458_Meas_Junction, Value = 26.55 20:51:22 Integrated Voltage Measurement... 20:51:53 Voltage Offset Correction: v_off_ini = 0.000002828 V, v_off_fin = 0.000005049 V 20:51:53 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142793575 Vs 20:51:53 Integrated Voltage Measurement... 20:52:25 Voltage Offset Correction: v_off_ini = 0.000003780 V, v_off_fin = 0.000000774 V 20:52:25 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142739097 Vs 20:52:26   Voltage Measurement, V = 0.000000 V 20:52:26 Temperature Measurement, Probe Number = 0, T = 25.747000 C 20:52:27 Temperature Measurement, Probe Number = 1, T = 26.540000 C 20:52:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.75 P2 = 3458_Meas_Junction, Value = 26.54 20:52:27 Integrated Voltage Measurement... 20:52:59 Voltage Offset Correction: v_off_ini = 0.000002613 V, v_off_fin = 0.000003402 V 20:52:59 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142777932 Vs 20:52:59 Integrated Voltage Measurement... 20:53:29 Voltage Offset Correction: v_off_ini = 0.000003844 V, v_off_fin = 0.000001754 V 20:53:29 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142743546 Vs 20:53:30   Voltage Measurement, V = 0.000000 V 20:53:31 Temperature Measurement, Probe Number = 0, T = 25.758000 C 20:53:32 Temperature Measurement, Probe Number = 1, T = 26.542000 C 20:53:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.76 P2 = 3458_Meas_Junction, Value = 26.54 20:53:32 Integrated Voltage Measurement... 20:54:03 Voltage Offset Correction: v_off_ini = 0.000002584 V, v_off_fin = 0.000004613 V 20:54:03 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142787712 Vs 20:54:03 Integrated Voltage Measurement... 20:54:35 Voltage Offset Correction: v_off_ini = 0.000003938 V, v_off_fin = 0.000001265 V 20:54:35 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142749949 Vs 20:54:36   Voltage Measurement, V = 0.000000 V 20:54:37 Temperature Measurement, Probe Number = 0, T = 25.756000 C 20:54:37 Temperature Measurement, Probe Number = 1, T = 26.543000 C 20:54:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.76 P2 = 3458_Meas_Junction, Value = 26.54 20:54:37 Integrated Voltage Measurement... 20:55:10 Voltage Offset Correction: v_off_ini = 0.000002703 V, v_off_fin = 0.000004869 V 20:55:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142796808 Vs 20:55:10 Integrated Voltage Measurement... 20:55:41 Voltage Offset Correction: v_off_ini = 0.000003720 V, v_off_fin = 0.000000229 V 20:55:41 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142731299 Vs 20:55:42   Voltage Measurement, V = 0.000000 V 20:55:43 Temperature Measurement, Probe Number = 0, T = 25.750000 C 20:55:43 Temperature Measurement, Probe Number = 1, T = 26.538000 C 20:55:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.75 P2 = 3458_Meas_Junction, Value = 26.54 20:55:43 Integrated Voltage Measurement... 20:56:14 Voltage Offset Correction: v_off_ini = 0.000002602 V, v_off_fin = 0.000004868 V 20:56:14 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142776231 Vs 20:56:14 Integrated Voltage Measurement... 20:56:46 Voltage Offset Correction: v_off_ini = 0.000004124 V, v_off_fin = 0.000002518 V 20:56:46 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142754557 Vs 20:56:47   Voltage Measurement, V = 0.000000 V 20:56:48 Temperature Measurement, Probe Number = 0, T = 25.758000 C 20:56:49 Temperature Measurement, Probe Number = 1, T = 26.542000 C 20:56:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.76 P2 = 3458_Meas_Junction, Value = 26.54 20:56:49 Integrated Voltage Measurement... 20:57:20 Voltage Offset Correction: v_off_ini = 0.000002511 V, v_off_fin = 0.000004497 V 20:57:20 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142794955 Vs 20:57:20 Integrated Voltage Measurement... 20:57:52 Voltage Offset Correction: v_off_ini = 0.000004017 V, v_off_fin = 0.000003256 V 20:57:52 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142736491 Vs 20:57:53   Voltage Measurement, V = 0.000000 V 20:57:54 Temperature Measurement, Probe Number = 0, T = 25.745000 C 20:57:54 Temperature Measurement, Probe Number = 1, T = 26.541000 C 20:57:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.75 P2 = 3458_Meas_Junction, Value = 26.54 20:57:54 Integrated Voltage Measurement... 20:58:27 Voltage Offset Correction: v_off_ini = 0.000002878 V, v_off_fin = 0.000004337 V 20:58:27 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.142746378 Vs 20:58:27 Integrated Voltage Measurement... 20:58:57 Voltage Offset Correction: v_off_ini = 0.000003954 V, v_off_fin = 0.000000876 V 20:58:57 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142736021 Vs 20:58:58   Voltage Measurement, V = 0.000000 V 20:58:59 Temperature Measurement, Probe Number = 0, T = 25.744000 C 20:59:00 Temperature Measurement, Probe Number = 1, T = 26.541000 C 20:59:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.74 P2 = 3458_Meas_Junction, Value = 26.54 20:59:00 Integrated Voltage Measurement... 20:59:31 Voltage Offset Correction: v_off_ini = 0.000002626 V, v_off_fin = 0.000004791 V 20:59:31 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142783616 Vs 20:59:31 Integrated Voltage Measurement... 21:00:01 Voltage Offset Correction: v_off_ini = 0.000003973 V, v_off_fin = 0.000001664 V 21:00:01 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142742522 Vs