SLAC Magnetic Measurements Date: 10-19-2020 Time: 17:37:56 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_015_Cell_47_Upstairs Serial Number: PC97084 Run Number: 4 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement upstairs, cable through switch. Full Set 4 17:38:15 Ambient Measurement Device(s) Being Used, type = None 17:38:15 Magnet Voltage Measurement Device(s) Being Used, type = None 17:38:15 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 17:38:15 XMAG Device(s) Being Used, type = None 17:38:15 Ambient Measurement Device(s) Being Used, type = None 17:38:57   Voltage Measurement, V = 0.000000 V 17:38:58 Temperature Measurement, Probe Number = 0, T = 27.499000 C 17:38:58 Temperature Measurement, Probe Number = 1, T = 27.430000 C 17:38:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.50 P2 = 3458_Meas_Junction, Value = 27.43 17:38:58 Integrated Voltage Measurement... 17:39:26 Voltage Offset Correction: v_off_ini = 0.000003581 V, v_off_fin = 0.000005020 V 17:39:26 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.142865214 Vs 17:39:26 Integrated Voltage Measurement... 17:39:59 Voltage Offset Correction: v_off_ini = 0.000004401 V, v_off_fin = 0.000002196 V 17:39:59 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142823301 Vs 17:40:00   Voltage Measurement, V = 0.000000 V 17:40:01 Temperature Measurement, Probe Number = 0, T = 27.503000 C 17:40:01 Temperature Measurement, Probe Number = 1, T = 27.429000 C 17:40:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.50 P2 = 3458_Meas_Junction, Value = 27.43 17:40:01 Integrated Voltage Measurement... 17:40:33 Voltage Offset Correction: v_off_ini = 0.000003954 V, v_off_fin = 0.000005516 V 17:40:33 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142853371 Vs 17:40:33 Integrated Voltage Measurement... 17:41:21 Voltage Offset Correction: v_off_ini = 0.000004400 V, v_off_fin = 0.000001707 V 17:41:21 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142817662 Vs 17:41:22   Voltage Measurement, V = 0.000000 V 17:41:22 Temperature Measurement, Probe Number = 0, T = 27.504000 C 17:41:23 Temperature Measurement, Probe Number = 1, T = 27.421000 C 17:41:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.50 P2 = 3458_Meas_Junction, Value = 27.42 17:41:23 Integrated Voltage Measurement... 17:42:01 Voltage Offset Correction: v_off_ini = 0.000003938 V, v_off_fin = 0.000005759 V 17:42:01 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142857685 Vs 17:42:01 Integrated Voltage Measurement... 17:42:52 Voltage Offset Correction: v_off_ini = 0.000003224 V, v_off_fin = 0.000001140 V 17:42:52 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142821123 Vs 17:42:53   Voltage Measurement, V = 0.000000 V 17:42:54 Temperature Measurement, Probe Number = 0, T = 27.510000 C 17:42:54 Temperature Measurement, Probe Number = 1, T = 27.415000 C 17:42:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.51 P2 = 3458_Meas_Junction, Value = 27.41 17:42:54 Integrated Voltage Measurement... 17:43:29 Voltage Offset Correction: v_off_ini = 0.000003511 V, v_off_fin = 0.000004460 V 17:43:29 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142865837 Vs 17:43:29 Integrated Voltage Measurement... 17:44:03 Voltage Offset Correction: v_off_ini = 0.000004747 V, v_off_fin = 0.000002218 V 17:44:03 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142813271 Vs 17:44:04   Voltage Measurement, V = 0.000000 V 17:44:04 Temperature Measurement, Probe Number = 0, T = 27.517000 C 17:44:05 Temperature Measurement, Probe Number = 1, T = 27.403000 C 17:44:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.52 P2 = 3458_Meas_Junction, Value = 27.40 17:44:05 Integrated Voltage Measurement... 17:44:37 Voltage Offset Correction: v_off_ini = 0.000003651 V, v_off_fin = 0.000004240 V 17:44:37 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142865621 Vs 17:44:37 Integrated Voltage Measurement... 17:45:11 Voltage Offset Correction: v_off_ini = 0.000004484 V, v_off_fin = 0.000002232 V 17:45:11 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142818392 Vs 17:45:12   Voltage Measurement, V = 0.000000 V 17:45:12 Temperature Measurement, Probe Number = 0, T = 27.514000 C 17:45:13 Temperature Measurement, Probe Number = 1, T = 27.396000 C 17:45:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.51 P2 = 3458_Meas_Junction, Value = 27.40 17:45:13 Integrated Voltage Measurement... 17:45:45 Voltage Offset Correction: v_off_ini = 0.000003593 V, v_off_fin = 0.000005085 V 17:45:45 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142864668 Vs 17:45:45 Integrated Voltage Measurement... 17:46:17 Voltage Offset Correction: v_off_ini = 0.000004458 V, v_off_fin = 0.000001545 V 17:46:17 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142808413 Vs 17:46:18   Voltage Measurement, V = 0.000000 V 17:46:18 Temperature Measurement, Probe Number = 0, T = 27.515000 C 17:46:19 Temperature Measurement, Probe Number = 1, T = 27.385000 C 17:46:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.52 P2 = 3458_Meas_Junction, Value = 27.39 17:46:19 Integrated Voltage Measurement... 17:46:52 Voltage Offset Correction: v_off_ini = 0.000003709 V, v_off_fin = 0.000005236 V 17:46:52 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142852642 Vs 17:46:52 Integrated Voltage Measurement... 17:47:26 Voltage Offset Correction: v_off_ini = 0.000004556 V, v_off_fin = 0.000002155 V 17:47:26 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142819589 Vs 17:47:27   Voltage Measurement, V = 0.000000 V 17:47:27 Temperature Measurement, Probe Number = 0, T = 27.518000 C 17:47:28 Temperature Measurement, Probe Number = 1, T = 27.379000 C 17:47:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.52 P2 = 3458_Meas_Junction, Value = 27.38 17:47:28 Integrated Voltage Measurement... 17:48:00 Voltage Offset Correction: v_off_ini = 0.000003033 V, v_off_fin = 0.000004575 V 17:48:00 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142854136 Vs 17:48:00 Integrated Voltage Measurement... 17:48:38 Voltage Offset Correction: v_off_ini = 0.000004703 V, v_off_fin = 0.000002702 V 17:48:38 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142819335 Vs 17:48:39   Voltage Measurement, V = 0.000000 V 17:48:39 Temperature Measurement, Probe Number = 0, T = 27.516000 C 17:48:40 Temperature Measurement, Probe Number = 1, T = 27.370000 C 17:48:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.52 P2 = 3458_Meas_Junction, Value = 27.37 17:48:40 Integrated Voltage Measurement... 17:49:13 Voltage Offset Correction: v_off_ini = 0.000003510 V, v_off_fin = 0.000005453 V 17:49:13 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142863978 Vs 17:49:13 Integrated Voltage Measurement... 17:49:50 Voltage Offset Correction: v_off_ini = 0.000004821 V, v_off_fin = 0.000001760 V 17:49:50 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142821855 Vs 17:49:51   Voltage Measurement, V = 0.000000 V 17:49:52 Temperature Measurement, Probe Number = 0, T = 27.512000 C 17:49:52 Temperature Measurement, Probe Number = 1, T = 27.367000 C 17:49:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.51 P2 = 3458_Meas_Junction, Value = 27.37 17:49:52 Integrated Voltage Measurement... 17:50:25 Voltage Offset Correction: v_off_ini = 0.000003007 V, v_off_fin = 0.000005246 V 17:50:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142867957 Vs 17:50:25 Integrated Voltage Measurement... 17:51:00 Voltage Offset Correction: v_off_ini = 0.000004020 V, v_off_fin = 0.000000742 V 17:51:00 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142811761 Vs