SLAC Magnetic Measurements Date: 01-20-2021 Time: 20:02:13 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_015_Cell_47 Serial Number: PC33408 Run Number: 16 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 16, no beam between 15 & 16 20:02:30 Ambient Measurement Device(s) Being Used, type = None 20:02:30 Magnet Voltage Measurement Device(s) Being Used, type = None 20:02:31 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 20:02:31 XMAG Device(s) Being Used, type = None 20:02:31 Ambient Measurement Device(s) Being Used, type = None 20:02:36   Voltage Measurement, V = 0.000000 V 20:02:37 Temperature Measurement, Probe Number = 0, T = 21.497000 C 20:02:37 Temperature Measurement, Probe Number = 1, T = 22.531000 C 20:02:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.50 P2 = 3458_Meas_Junction, Value = 22.53 20:02:37 Integrated Voltage Measurement... 20:03:06 Voltage Offset Correction: v_off_ini = 0.000000543 V, v_off_fin = 0.000001284 V 20:03:06 Integrated Voltage Measurement Delta Gap = 0.0039995 m VT = 0.142694717 Vs 20:03:06 Integrated Voltage Measurement... 20:03:37 Voltage Offset Correction: v_off_ini = 0.000000787 V, v_off_fin = -0.000002039 V 20:03:37 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142716137 Vs 20:03:38   Voltage Measurement, V = 0.000000 V 20:03:39 Temperature Measurement, Probe Number = 0, T = 21.517000 C 20:03:39 Temperature Measurement, Probe Number = 1, T = 22.502000 C 20:03:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.52 P2 = 3458_Meas_Junction, Value = 22.50 20:03:39 Integrated Voltage Measurement... 20:04:14 Voltage Offset Correction: v_off_ini = -0.000000349 V, v_off_fin = 0.000000347 V 20:04:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142770273 Vs 20:04:14 Integrated Voltage Measurement... 20:04:45 Voltage Offset Correction: v_off_ini = 0.000000741 V, v_off_fin = -0.000001987 V 20:04:45 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142725491 Vs 20:04:46   Voltage Measurement, V = 0.000000 V 20:04:47 Temperature Measurement, Probe Number = 0, T = 21.554000 C 20:04:48 Temperature Measurement, Probe Number = 1, T = 22.520000 C 20:04:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.55 P2 = 3458_Meas_Junction, Value = 22.52 20:04:48 Integrated Voltage Measurement... 20:05:20 Voltage Offset Correction: v_off_ini = -0.000000698 V, v_off_fin = 0.000000294 V 20:05:20 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142770704 Vs 20:05:20 Integrated Voltage Measurement... 20:05:58 Voltage Offset Correction: v_off_ini = 0.000000694 V, v_off_fin = -0.000002043 V 20:05:58 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142710297 Vs 20:05:59   Voltage Measurement, V = 0.000000 V 20:06:00 Temperature Measurement, Probe Number = 0, T = 21.575000 C 20:06:00 Temperature Measurement, Probe Number = 1, T = 22.466000 C 20:06:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.57 P2 = 3458_Meas_Junction, Value = 22.47 20:06:00 Integrated Voltage Measurement... 20:06:31 Voltage Offset Correction: v_off_ini = -0.000000700 V, v_off_fin = 0.000000851 V 20:06:31 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142756796 Vs 20:06:31 Integrated Voltage Measurement... 20:07:02 Voltage Offset Correction: v_off_ini = 0.000000604 V, v_off_fin = -0.000002526 V 20:07:02 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142706551 Vs 20:07:03   Voltage Measurement, V = 0.000000 V 20:07:04 Temperature Measurement, Probe Number = 0, T = 21.568000 C 20:07:04 Temperature Measurement, Probe Number = 1, T = 22.510000 C 20:07:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.57 P2 = 3458_Meas_Junction, Value = 22.51 20:07:04 Integrated Voltage Measurement... 20:07:36 Voltage Offset Correction: v_off_ini = -0.000000545 V, v_off_fin = 0.000000717 V 20:07:36 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142761143 Vs 20:07:36 Integrated Voltage Measurement... 20:08:08 Voltage Offset Correction: v_off_ini = 0.000000459 V, v_off_fin = -0.000002976 V 20:08:08 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142719378 Vs 20:08:09   Voltage Measurement, V = 0.000000 V 20:08:09 Temperature Measurement, Probe Number = 0, T = 21.564000 C 20:08:10 Temperature Measurement, Probe Number = 1, T = 22.519000 C 20:08:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.56 P2 = 3458_Meas_Junction, Value = 22.52 20:08:10 Integrated Voltage Measurement... 20:08:41 Voltage Offset Correction: v_off_ini = -0.000000918 V, v_off_fin = 0.000000864 V 20:08:41 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142769071 Vs 20:08:41 Integrated Voltage Measurement... 20:09:12 Voltage Offset Correction: v_off_ini = 0.000000485 V, v_off_fin = -0.000002636 V 20:09:12 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142719383 Vs 20:09:13   Voltage Measurement, V = 0.000000 V 20:09:13 Temperature Measurement, Probe Number = 0, T = 21.558000 C 20:09:14 Temperature Measurement, Probe Number = 1, T = 22.512000 C 20:09:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.56 P2 = 3458_Meas_Junction, Value = 22.51 20:09:14 Integrated Voltage Measurement... 20:10:11 Voltage Offset Correction: v_off_ini = -0.000000283 V, v_off_fin = 0.000000643 V 20:10:11 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142774239 Vs 20:10:11 Integrated Voltage Measurement... 20:10:45 Voltage Offset Correction: v_off_ini = 0.000000500 V, v_off_fin = -0.000001203 V 20:10:45 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142717619 Vs 20:10:46   Voltage Measurement, V = 0.000000 V 20:10:47 Temperature Measurement, Probe Number = 0, T = 21.552000 C 20:10:47 Temperature Measurement, Probe Number = 1, T = 22.512000 C 20:10:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.55 P2 = 3458_Meas_Junction, Value = 22.51 20:10:47 Integrated Voltage Measurement... 20:11:24 Voltage Offset Correction: v_off_ini = -0.000000442 V, v_off_fin = 0.000001028 V 20:11:24 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142766922 Vs 20:11:24 Integrated Voltage Measurement... 20:11:54 Voltage Offset Correction: v_off_ini = 0.000000585 V, v_off_fin = -0.000001091 V 20:11:54 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142721673 Vs 20:11:55   Voltage Measurement, V = 0.000000 V 20:11:56 Temperature Measurement, Probe Number = 0, T = 21.567000 C 20:11:56 Temperature Measurement, Probe Number = 1, T = 22.529000 C 20:11:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.57 P2 = 3458_Meas_Junction, Value = 22.53 20:11:56 Integrated Voltage Measurement... 20:12:27 Voltage Offset Correction: v_off_ini = -0.000000926 V, v_off_fin = 0.000000227 V 20:12:27 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142771654 Vs 20:12:27 Integrated Voltage Measurement... 20:13:01 Voltage Offset Correction: v_off_ini = 0.000000528 V, v_off_fin = -0.000002411 V 20:13:01 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142709589 Vs 20:13:02   Voltage Measurement, V = 0.000000 V 20:13:03 Temperature Measurement, Probe Number = 0, T = 21.580000 C 20:13:04 Temperature Measurement, Probe Number = 1, T = 22.533000 C 20:13:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.58 P2 = 3458_Meas_Junction, Value = 22.53 20:13:04 Integrated Voltage Measurement... 20:13:34 Voltage Offset Correction: v_off_ini = -0.000000742 V, v_off_fin = 0.000000842 V 20:13:34 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142766286 Vs 20:13:34 Integrated Voltage Measurement... 20:14:06 Voltage Offset Correction: v_off_ini = 0.000000526 V, v_off_fin = -0.000001523 V 20:14:06 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142720719 Vs