SLAC Magnetic Measurements Date: 10-21-2020 Time: 15:28:27 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_015_Cell_47 Serial Number: PC33408 Run Number: 11 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 11 15:28:45 Ambient Measurement Device(s) Being Used, type = None 15:28:45 Magnet Voltage Measurement Device(s) Being Used, type = None 15:28:46 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:28:46 XMAG Device(s) Being Used, type = None 15:28:46 Ambient Measurement Device(s) Being Used, type = None 15:28:49   Voltage Measurement, V = 0.000000 V 15:28:50 Temperature Measurement, Probe Number = 0, T = 21.801000 C 15:28:51 Temperature Measurement, Probe Number = 1, T = 20.681000 C 15:28:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.80 P2 = 3458_Meas_Junction, Value = 20.68 15:28:51 Integrated Voltage Measurement... 15:29:19 Voltage Offset Correction: v_off_ini = -0.000000231 V, v_off_fin = 0.000000776 V 15:29:19 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.142843001 Vs 15:29:19 Integrated Voltage Measurement... 15:29:51 Voltage Offset Correction: v_off_ini = -0.000000099 V, v_off_fin = -0.000002106 V 15:29:51 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142765359 Vs 15:29:52   Voltage Measurement, V = 0.000000 V 15:29:53 Temperature Measurement, Probe Number = 0, T = 21.777000 C 15:29:53 Temperature Measurement, Probe Number = 1, T = 20.704000 C 15:29:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.78 P2 = 3458_Meas_Junction, Value = 20.70 15:29:53 Integrated Voltage Measurement... 15:30:25 Voltage Offset Correction: v_off_ini = -0.000001135 V, v_off_fin = -0.000000674 V 15:30:25 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142801458 Vs 15:30:25 Integrated Voltage Measurement... 15:30:57 Voltage Offset Correction: v_off_ini = -0.000000020 V, v_off_fin = -0.000001859 V 15:30:57 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142779895 Vs 15:30:58   Voltage Measurement, V = 0.000000 V 15:30:59 Temperature Measurement, Probe Number = 0, T = 21.791000 C 15:30:59 Temperature Measurement, Probe Number = 1, T = 20.709000 C 15:30:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.79 P2 = 3458_Meas_Junction, Value = 20.71 15:30:59 Integrated Voltage Measurement... 15:31:32 Voltage Offset Correction: v_off_ini = -0.000001206 V, v_off_fin = -0.000000102 V 15:31:32 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142829128 Vs 15:31:32 Integrated Voltage Measurement... 15:32:03 Voltage Offset Correction: v_off_ini = -0.000000233 V, v_off_fin = -0.000002641 V 15:32:03 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142788544 Vs 15:32:04   Voltage Measurement, V = 0.000000 V 15:32:05 Temperature Measurement, Probe Number = 0, T = 21.774000 C 15:32:05 Temperature Measurement, Probe Number = 1, T = 20.701000 C 15:32:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.77 P2 = 3458_Meas_Junction, Value = 20.70 15:32:05 Integrated Voltage Measurement... 15:32:36 Voltage Offset Correction: v_off_ini = -0.000001210 V, v_off_fin = 0.000000267 V 15:32:36 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142837346 Vs 15:32:36 Integrated Voltage Measurement... 15:33:09 Voltage Offset Correction: v_off_ini = -0.000000236 V, v_off_fin = -0.000002525 V 15:33:09 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142782414 Vs 15:33:10   Voltage Measurement, V = 0.000000 V 15:33:10 Temperature Measurement, Probe Number = 0, T = 21.767000 C 15:33:11 Temperature Measurement, Probe Number = 1, T = 20.699000 C 15:33:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.77 P2 = 3458_Meas_Junction, Value = 20.70 15:33:11 Integrated Voltage Measurement... 15:33:42 Voltage Offset Correction: v_off_ini = -0.000001469 V, v_off_fin = 0.000000362 V 15:33:42 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142828343 Vs 15:33:42 Integrated Voltage Measurement... 15:34:13 Voltage Offset Correction: v_off_ini = -0.000000009 V, v_off_fin = -0.000003800 V 15:34:13 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142787533 Vs 15:34:14   Voltage Measurement, V = 0.000000 V 15:34:14 Temperature Measurement, Probe Number = 0, T = 21.758000 C 15:34:15 Temperature Measurement, Probe Number = 1, T = 20.699000 C 15:34:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.76 P2 = 3458_Meas_Junction, Value = 20.70 15:34:15 Integrated Voltage Measurement... 15:34:48 Voltage Offset Correction: v_off_ini = -0.000001483 V, v_off_fin = -0.000000198 V 15:34:48 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142829958 Vs 15:34:48 Integrated Voltage Measurement... 15:35:18 Voltage Offset Correction: v_off_ini = -0.000000110 V, v_off_fin = -0.000002796 V 15:35:18 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142787497 Vs 15:35:19   Voltage Measurement, V = 0.000000 V 15:35:20 Temperature Measurement, Probe Number = 0, T = 21.752000 C 15:35:21 Temperature Measurement, Probe Number = 1, T = 20.700000 C 15:35:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.75 P2 = 3458_Meas_Junction, Value = 20.70 15:35:21 Integrated Voltage Measurement... 15:35:53 Voltage Offset Correction: v_off_ini = -0.000001544 V, v_off_fin = 0.000000341 V 15:35:53 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142829069 Vs 15:35:53 Integrated Voltage Measurement... 15:36:24 Voltage Offset Correction: v_off_ini = 0.000000085 V, v_off_fin = -0.000004223 V 15:36:24 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142785164 Vs 15:36:25   Voltage Measurement, V = 0.000000 V 15:36:26 Temperature Measurement, Probe Number = 0, T = 21.750000 C 15:36:26 Temperature Measurement, Probe Number = 1, T = 20.699000 C 15:36:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.75 P2 = 3458_Meas_Junction, Value = 20.70 15:36:26 Integrated Voltage Measurement... 15:36:57 Voltage Offset Correction: v_off_ini = -0.000001274 V, v_off_fin = 0.000000893 V 15:36:57 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142822587 Vs 15:36:57 Integrated Voltage Measurement... 15:37:30 Voltage Offset Correction: v_off_ini = 0.000000020 V, v_off_fin = -0.000002440 V 15:37:30 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142756956 Vs 15:37:31   Voltage Measurement, V = 0.000000 V 15:37:31 Temperature Measurement, Probe Number = 0, T = 21.752000 C 15:37:32 Temperature Measurement, Probe Number = 1, T = 20.700000 C 15:37:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.75 P2 = 3458_Meas_Junction, Value = 20.70 15:37:32 Integrated Voltage Measurement... 15:38:09 Voltage Offset Correction: v_off_ini = -0.000000707 V, v_off_fin = -0.000000381 V 15:38:09 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142792661 Vs 15:38:09 Integrated Voltage Measurement... 15:38:41 Voltage Offset Correction: v_off_ini = -0.000000370 V, v_off_fin = -0.000002836 V 15:38:41 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142787998 Vs 15:38:42   Voltage Measurement, V = 0.000000 V 15:38:42 Temperature Measurement, Probe Number = 0, T = 21.773000 C 15:38:43 Temperature Measurement, Probe Number = 1, T = 20.699000 C 15:38:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.77 P2 = 3458_Meas_Junction, Value = 20.70 15:38:43 Integrated Voltage Measurement... 15:39:14 Voltage Offset Correction: v_off_ini = -0.000001442 V, v_off_fin = 0.000000296 V 15:39:14 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142829697 Vs 15:39:14 Integrated Voltage Measurement... 15:39:44 Voltage Offset Correction: v_off_ini = 0.000000064 V, v_off_fin = -0.000003547 V 15:39:44 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142783896 Vs