SLAC Magnetic Measurements Date: 10-06-2020 Time: 18:43:19 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_015_Cell_47 Serial Number: PC33408 Run Number: 10 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 10 18:43:22 Ambient Measurement Device(s) Being Used, type = None 18:43:22 Magnet Voltage Measurement Device(s) Being Used, type = None 18:43:22 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 18:43:22 XMAG Device(s) Being Used, type = None 18:43:22 Ambient Measurement Device(s) Being Used, type = None 18:43:30   Voltage Measurement, V = 0.000000 V 18:43:31 Temperature Measurement, Probe Number = 0, T = 21.910000 C 18:43:31 Temperature Measurement, Probe Number = 1, T = 21.846000 C 18:43:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.91 P2 = 3458_Meas_Junction, Value = 21.85 18:43:32 Integrated Voltage Measurement... 18:43:58 Voltage Offset Correction: v_off_ini = -0.000000536 V, v_off_fin = -0.000001147 V 18:43:58 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.142884386 Vs 18:43:58 Integrated Voltage Measurement... 18:44:30 Voltage Offset Correction: v_off_ini = 0.000000108 V, v_off_fin = -0.000002164 V 18:44:30 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142829497 Vs 18:44:31   Voltage Measurement, V = 0.000000 V 18:44:31 Temperature Measurement, Probe Number = 0, T = 21.923000 C 18:44:32 Temperature Measurement, Probe Number = 1, T = 21.858000 C 18:44:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.92 P2 = 3458_Meas_Junction, Value = 21.86 18:44:32 Integrated Voltage Measurement... 18:46:26 Voltage Offset Correction: v_off_ini = -0.000000249 V, v_off_fin = 0.000000055 V 18:46:26 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.142884146 Vs 18:46:26 Integrated Voltage Measurement... 18:46:57 Voltage Offset Correction: v_off_ini = -0.000000294 V, v_off_fin = -0.000003645 V 18:46:57 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142830422 Vs 18:46:58   Voltage Measurement, V = 0.000000 V 18:46:59 Temperature Measurement, Probe Number = 0, T = 21.987000 C 18:47:00 Temperature Measurement, Probe Number = 1, T = 21.894000 C 18:47:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.99 P2 = 3458_Meas_Junction, Value = 21.89 18:47:00 Integrated Voltage Measurement... 18:47:30 Voltage Offset Correction: v_off_ini = -0.000001709 V, v_off_fin = -0.000000051 V 18:47:30 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142880368 Vs 18:47:30 Integrated Voltage Measurement... 18:48:03 Voltage Offset Correction: v_off_ini = -0.000000144 V, v_off_fin = -0.000000199 V 18:48:03 Integrated Voltage Measurement Delta Gap = 0.0000001 m VT = -0.000004724 Vs 18:48:04   Voltage Measurement, V = 0.000000 V 18:48:05 Temperature Measurement, Probe Number = 0, T = 21.959000 C 18:48:05 Temperature Measurement, Probe Number = 1, T = 21.897000 C 18:48:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.96 P2 = 3458_Meas_Junction, Value = 21.90 18:48:05 Integrated Voltage Measurement... 18:49:03 Voltage Offset Correction: v_off_ini = -0.000001727 V, v_off_fin = -0.000000850 V 18:49:03 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142875141 Vs 18:49:03 Integrated Voltage Measurement... 18:49:36 Voltage Offset Correction: v_off_ini = -0.000000265 V, v_off_fin = -0.000002181 V 18:49:36 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142819221 Vs 18:49:37   Voltage Measurement, V = 0.000000 V 18:49:38 Temperature Measurement, Probe Number = 0, T = 21.941000 C 18:49:38 Temperature Measurement, Probe Number = 1, T = 21.918000 C 18:49:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.94 P2 = 3458_Meas_Junction, Value = 21.92 18:49:38 Integrated Voltage Measurement... 18:50:10 Voltage Offset Correction: v_off_ini = -0.000001190 V, v_off_fin = 0.000000572 V 18:50:10 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142869157 Vs 18:50:10 Integrated Voltage Measurement... 18:50:43 Voltage Offset Correction: v_off_ini = -0.000000171 V, v_off_fin = -0.000002657 V 18:50:43 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142821233 Vs 18:50:44   Voltage Measurement, V = 0.000000 V 18:50:45 Temperature Measurement, Probe Number = 0, T = 21.937000 C 18:50:45 Temperature Measurement, Probe Number = 1, T = 21.919000 C 18:50:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.94 P2 = 3458_Meas_Junction, Value = 21.92 18:50:45 Integrated Voltage Measurement... 18:51:17 Voltage Offset Correction: v_off_ini = -0.000001380 V, v_off_fin = -0.000000734 V 18:51:17 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142858721 Vs 18:51:17 Integrated Voltage Measurement... 18:51:49 Voltage Offset Correction: v_off_ini = -0.000000092 V, v_off_fin = -0.000002483 V 18:51:49 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142819279 Vs 18:51:50   Voltage Measurement, V = 0.000000 V 18:51:51 Temperature Measurement, Probe Number = 0, T = 21.941000 C 18:51:51 Temperature Measurement, Probe Number = 1, T = 21.912000 C 18:51:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.94 P2 = 3458_Meas_Junction, Value = 21.91 18:51:51 Integrated Voltage Measurement... 18:52:22 Voltage Offset Correction: v_off_ini = -0.000001610 V, v_off_fin = -0.000000381 V 18:52:22 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142866309 Vs 18:52:22 Integrated Voltage Measurement... 18:52:53 Voltage Offset Correction: v_off_ini = -0.000000157 V, v_off_fin = -0.000003144 V 18:52:53 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142831651 Vs 18:52:54   Voltage Measurement, V = 0.000000 V 18:52:55 Temperature Measurement, Probe Number = 0, T = 21.941000 C 18:52:56 Temperature Measurement, Probe Number = 1, T = 21.908000 C 18:52:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.94 P2 = 3458_Meas_Junction, Value = 21.91 18:52:56 Integrated Voltage Measurement... 18:53:27 Voltage Offset Correction: v_off_ini = -0.000001626 V, v_off_fin = 0.000000194 V 18:53:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142876709 Vs 18:53:27 Integrated Voltage Measurement... 18:53:57 Voltage Offset Correction: v_off_ini = -0.000000016 V, v_off_fin = -0.000002592 V 18:53:57 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142826834 Vs 18:53:58   Voltage Measurement, V = 0.000000 V 18:53:59 Temperature Measurement, Probe Number = 0, T = 21.940000 C 18:53:59 Temperature Measurement, Probe Number = 1, T = 21.905000 C 18:53:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.94 P2 = 3458_Meas_Junction, Value = 21.91 18:53:59 Integrated Voltage Measurement... 18:54:30 Voltage Offset Correction: v_off_ini = -0.000001348 V, v_off_fin = 0.000000018 V 18:54:30 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142872375 Vs 18:54:30 Integrated Voltage Measurement... 18:55:04 Voltage Offset Correction: v_off_ini = 0.000000089 V, v_off_fin = -0.000001592 V 18:55:04 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142801316 Vs 18:55:05   Voltage Measurement, V = 0.000000 V 18:55:06 Temperature Measurement, Probe Number = 0, T = 21.938000 C 18:55:06 Temperature Measurement, Probe Number = 1, T = 21.906000 C 18:55:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.94 P2 = 3458_Meas_Junction, Value = 21.91 18:55:06 Integrated Voltage Measurement... 18:55:42 Voltage Offset Correction: v_off_ini = -0.000000921 V, v_off_fin = 0.000000028 V 18:55:42 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142842649 Vs 18:55:42 Integrated Voltage Measurement... 18:56:13 Voltage Offset Correction: v_off_ini = -0.000000030 V, v_off_fin = -0.000002886 V 18:56:13 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142822319 Vs