SLAC Magnetic Measurements Date: 09-09-2020 Time: 14:46:36 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_015_Cell_46_Upstairs Serial Number: PC97084 Run Number: 1 Measurement Device: WalkerVS Operator: sda Comment: Coil Integral measurement upstairs, cable straight into 3458A. Set 1 14:46:39 Ambient Measurement Device(s) Being Used, type = None 14:46:39 Magnet Voltage Measurement Device(s) Being Used, type = None 14:46:39 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 14:46:39 XMAG Device(s) Being Used, type = None 14:46:39 Ambient Measurement Device(s) Being Used, type = None 14:46:56   Voltage Measurement, V = 0.000000 V 14:46:57 Temperature Measurement, Probe Number = 0, T = 27.183000 C 14:46:57 Temperature Measurement, Probe Number = 1, T = 27.090000 C 14:46:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.18 P2 = 3458_Meas_Junction, Value = 27.09 14:46:58 Integrated Voltage Measurement... 14:47:29 Voltage Offset Correction: v_off_ini = 0.000003872 V, v_off_fin = 0.000004632 V 14:47:29 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = 0.143393208 Vs 14:47:29 Integrated Voltage Measurement... 14:48:04 Voltage Offset Correction: v_off_ini = 0.000004240 V, v_off_fin = 0.000001604 V 14:48:04 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143430338 Vs 14:48:05   Voltage Measurement, V = 0.000000 V 14:48:06 Temperature Measurement, Probe Number = 0, T = 27.160000 C 14:48:06 Temperature Measurement, Probe Number = 1, T = 27.096000 C 14:48:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.16 P2 = 3458_Meas_Junction, Value = 27.10 14:48:06 Integrated Voltage Measurement... 14:48:43 Voltage Offset Correction: v_off_ini = 0.000002856 V, v_off_fin = 0.000005168 V 14:48:43 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143463716 Vs 14:48:43 Integrated Voltage Measurement... 14:49:16 Voltage Offset Correction: v_off_ini = 0.000004011 V, v_off_fin = 0.000001694 V 14:49:16 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143438010 Vs 14:49:17   Voltage Measurement, V = 0.000000 V 14:49:18 Temperature Measurement, Probe Number = 0, T = 27.159000 C 14:49:18 Temperature Measurement, Probe Number = 1, T = 27.097000 C 14:49:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.16 P2 = 3458_Meas_Junction, Value = 27.10 14:49:19 Integrated Voltage Measurement... 14:49:51 Voltage Offset Correction: v_off_ini = 0.000002975 V, v_off_fin = 0.000003927 V 14:49:51 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143464641 Vs 14:49:51 Integrated Voltage Measurement... 14:50:30 Voltage Offset Correction: v_off_ini = 0.000004159 V, v_off_fin = 0.000002021 V 14:50:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143432909 Vs 14:50:31   Voltage Measurement, V = 0.000000 V 14:50:31 Temperature Measurement, Probe Number = 0, T = 27.153000 C 14:50:32 Temperature Measurement, Probe Number = 1, T = 27.112000 C 14:50:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.15 P2 = 3458_Meas_Junction, Value = 27.11 14:50:32 Integrated Voltage Measurement... 14:51:03 Voltage Offset Correction: v_off_ini = 0.000003285 V, v_off_fin = 0.000004839 V 14:51:03 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143459136 Vs 14:51:03 Integrated Voltage Measurement... 14:51:34 Voltage Offset Correction: v_off_ini = 0.000004403 V, v_off_fin = 0.000000347 V 14:51:34 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143438588 Vs 14:51:35   Voltage Measurement, V = 0.000000 V 14:51:36 Temperature Measurement, Probe Number = 0, T = 27.154000 C 14:51:36 Temperature Measurement, Probe Number = 1, T = 27.113000 C 14:51:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.15 P2 = 3458_Meas_Junction, Value = 27.11 14:51:36 Integrated Voltage Measurement... 14:52:10 Voltage Offset Correction: v_off_ini = 0.000003050 V, v_off_fin = 0.000005539 V 14:52:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143467182 Vs 14:52:10 Integrated Voltage Measurement... 14:52:42 Voltage Offset Correction: v_off_ini = 0.000004351 V, v_off_fin = 0.000000982 V 14:52:42 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143428789 Vs 14:52:43   Voltage Measurement, V = 0.000000 V 14:52:44 Temperature Measurement, Probe Number = 0, T = 27.155000 C 14:52:44 Temperature Measurement, Probe Number = 1, T = 27.098000 C 14:52:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.16 P2 = 3458_Meas_Junction, Value = 27.10 14:52:44 Integrated Voltage Measurement... 14:53:16 Voltage Offset Correction: v_off_ini = 0.000003064 V, v_off_fin = 0.000004668 V 14:53:16 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143453573 Vs 14:53:16 Integrated Voltage Measurement... 14:53:46 Voltage Offset Correction: v_off_ini = 0.000004602 V, v_off_fin = 0.000001819 V 14:53:46 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143428527 Vs 14:53:47   Voltage Measurement, V = 0.000000 V 14:53:48 Temperature Measurement, Probe Number = 0, T = 27.159000 C 14:53:49 Temperature Measurement, Probe Number = 1, T = 27.108000 C 14:53:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.16 P2 = 3458_Meas_Junction, Value = 27.11 14:53:49 Integrated Voltage Measurement... 14:54:18 Voltage Offset Correction: v_off_ini = 0.000002999 V, v_off_fin = 0.000005657 V 14:54:18 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143463414 Vs 14:54:18 Integrated Voltage Measurement... 14:54:50 Voltage Offset Correction: v_off_ini = 0.000004105 V, v_off_fin = 0.000000901 V 14:54:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143427935 Vs 14:54:51   Voltage Measurement, V = 0.000000 V 14:54:52 Temperature Measurement, Probe Number = 0, T = 27.155000 C 14:54:53 Temperature Measurement, Probe Number = 1, T = 27.099000 C 14:54:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.16 P2 = 3458_Meas_Junction, Value = 27.10 14:54:53 Integrated Voltage Measurement... 14:55:24 Voltage Offset Correction: v_off_ini = 0.000002810 V, v_off_fin = 0.000005100 V 14:55:24 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143468488 Vs 14:55:24 Integrated Voltage Measurement... 14:55:55 Voltage Offset Correction: v_off_ini = 0.000004341 V, v_off_fin = 0.000001567 V 14:55:55 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143427509 Vs 14:55:56   Voltage Measurement, V = 0.000000 V 14:55:57 Temperature Measurement, Probe Number = 0, T = 27.159000 C 14:55:57 Temperature Measurement, Probe Number = 1, T = 27.113000 C 14:55:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.16 P2 = 3458_Meas_Junction, Value = 27.11 14:55:57 Integrated Voltage Measurement... 14:56:27 Voltage Offset Correction: v_off_ini = 0.000002381 V, v_off_fin = 0.000004822 V 14:56:27 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143456093 Vs 14:56:27 Integrated Voltage Measurement... 14:56:58 Voltage Offset Correction: v_off_ini = 0.000004228 V, v_off_fin = -0.000000081 V 14:56:58 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143427250 Vs 14:56:59   Voltage Measurement, V = 0.000000 V 14:56:59 Temperature Measurement, Probe Number = 0, T = 27.160000 C 14:57:00 Temperature Measurement, Probe Number = 1, T = 27.107000 C 14:57:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.16 P2 = 3458_Meas_Junction, Value = 27.11 14:57:00 Integrated Voltage Measurement... 14:57:31 Voltage Offset Correction: v_off_ini = 0.000002832 V, v_off_fin = 0.000004274 V 14:57:31 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143455115 Vs 14:57:31 Integrated Voltage Measurement... 14:58:02 Voltage Offset Correction: v_off_ini = 0.000004345 V, v_off_fin = 0.000001655 V 14:58:02 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143426133 Vs