SLAC Magnetic Measurements Date: 01-20-2021 Time: 19:48:07 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_014_Cell_46 Serial Number: PC33408 Run Number: 16 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 16, no beam between 15 & 16 19:48:24 Ambient Measurement Device(s) Being Used, type = None 19:48:24 Magnet Voltage Measurement Device(s) Being Used, type = None 19:48:25 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 19:48:25 XMAG Device(s) Being Used, type = None 19:48:25 Ambient Measurement Device(s) Being Used, type = None 19:48:37   Voltage Measurement, V = 0.000000 V 19:48:38 Temperature Measurement, Probe Number = 0, T = 21.418000 C 19:48:39 Temperature Measurement, Probe Number = 1, T = 22.308000 C 19:48:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.42 P2 = 3458_Meas_Junction, Value = 22.31 19:48:39 Integrated Voltage Measurement... 19:49:05 Voltage Offset Correction: v_off_ini = 0.000000743 V, v_off_fin = 0.000001790 V 19:49:05 Integrated Voltage Measurement Delta Gap = 0.0039996 m VT = 0.143332388 Vs 19:49:05 Integrated Voltage Measurement... 19:49:46 Voltage Offset Correction: v_off_ini = 0.000001084 V, v_off_fin = -0.000001746 V 19:49:46 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143360483 Vs 19:49:47   Voltage Measurement, V = 0.000000 V 19:49:48 Temperature Measurement, Probe Number = 0, T = 21.418000 C 19:49:49 Temperature Measurement, Probe Number = 1, T = 22.331000 C 19:49:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.42 P2 = 3458_Meas_Junction, Value = 22.33 19:49:49 Integrated Voltage Measurement... 19:50:21 Voltage Offset Correction: v_off_ini = -0.000000526 V, v_off_fin = 0.000000288 V 19:50:21 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143397554 Vs 19:50:21 Integrated Voltage Measurement... 19:50:52 Voltage Offset Correction: v_off_ini = 0.000001043 V, v_off_fin = -0.000001654 V 19:50:52 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143359321 Vs 19:50:53   Voltage Measurement, V = 0.000000 V 19:50:53 Temperature Measurement, Probe Number = 0, T = 21.426000 C 19:50:54 Temperature Measurement, Probe Number = 1, T = 22.369000 C 19:50:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.43 P2 = 3458_Meas_Junction, Value = 22.37 19:50:54 Integrated Voltage Measurement... 19:51:25 Voltage Offset Correction: v_off_ini = -0.000000757 V, v_off_fin = 0.000001515 V 19:51:25 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143399932 Vs 19:51:25 Integrated Voltage Measurement... 19:51:56 Voltage Offset Correction: v_off_ini = 0.000000925 V, v_off_fin = -0.000002894 V 19:51:56 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143357213 Vs 19:51:57   Voltage Measurement, V = 0.000000 V 19:51:58 Temperature Measurement, Probe Number = 0, T = 21.420000 C 19:51:59 Temperature Measurement, Probe Number = 1, T = 22.400000 C 19:51:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.42 P2 = 3458_Meas_Junction, Value = 22.40 19:51:59 Integrated Voltage Measurement... 19:52:30 Voltage Offset Correction: v_off_ini = -0.000001136 V, v_off_fin = 0.000001191 V 19:52:30 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143410952 Vs 19:52:30 Integrated Voltage Measurement... 19:53:01 Voltage Offset Correction: v_off_ini = 0.000000758 V, v_off_fin = -0.000003416 V 19:53:01 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143364220 Vs 19:53:02   Voltage Measurement, V = 0.000000 V 19:53:02 Temperature Measurement, Probe Number = 0, T = 21.422000 C 19:53:03 Temperature Measurement, Probe Number = 1, T = 22.413000 C 19:53:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.42 P2 = 3458_Meas_Junction, Value = 22.41 19:53:03 Integrated Voltage Measurement... 19:53:35 Voltage Offset Correction: v_off_ini = -0.000000963 V, v_off_fin = 0.000000656 V 19:53:35 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143409944 Vs 19:53:35 Integrated Voltage Measurement... 19:54:06 Voltage Offset Correction: v_off_ini = 0.000000787 V, v_off_fin = -0.000003232 V 19:54:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143364337 Vs 19:54:07   Voltage Measurement, V = 0.000000 V 19:54:07 Temperature Measurement, Probe Number = 0, T = 21.412000 C 19:54:08 Temperature Measurement, Probe Number = 1, T = 22.436000 C 19:54:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.41 P2 = 3458_Meas_Junction, Value = 22.44 19:54:08 Integrated Voltage Measurement... 19:54:39 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = 0.000001377 V 19:54:39 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143416861 Vs 19:54:39 Integrated Voltage Measurement... 19:55:14 Voltage Offset Correction: v_off_ini = 0.000000750 V, v_off_fin = -0.000002361 V 19:55:14 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143350116 Vs 19:55:15   Voltage Measurement, V = 0.000000 V 19:55:16 Temperature Measurement, Probe Number = 0, T = 21.400000 C 19:55:16 Temperature Measurement, Probe Number = 1, T = 22.435000 C 19:55:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.40 P2 = 3458_Meas_Junction, Value = 22.43 19:55:16 Integrated Voltage Measurement... 19:55:48 Voltage Offset Correction: v_off_ini = -0.000000858 V, v_off_fin = 0.000001624 V 19:55:48 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143389592 Vs 19:55:48 Integrated Voltage Measurement... 19:56:20 Voltage Offset Correction: v_off_ini = 0.000000889 V, v_off_fin = -0.000000778 V 19:56:20 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143354298 Vs 19:56:21   Voltage Measurement, V = 0.000000 V 19:56:21 Temperature Measurement, Probe Number = 0, T = 21.391000 C 19:56:22 Temperature Measurement, Probe Number = 1, T = 22.442000 C 19:56:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.39 P2 = 3458_Meas_Junction, Value = 22.44 19:56:22 Integrated Voltage Measurement... 19:56:54 Voltage Offset Correction: v_off_ini = -0.000000892 V, v_off_fin = 0.000000710 V 19:56:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143394827 Vs 19:56:54 Integrated Voltage Measurement... 19:57:25 Voltage Offset Correction: v_off_ini = 0.000000713 V, v_off_fin = -0.000002795 V 19:57:25 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143352957 Vs 19:57:26   Voltage Measurement, V = 0.000000 V 19:57:26 Temperature Measurement, Probe Number = 0, T = 21.390000 C 19:57:27 Temperature Measurement, Probe Number = 1, T = 22.453000 C 19:57:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.39 P2 = 3458_Meas_Junction, Value = 22.45 19:57:27 Integrated Voltage Measurement... 19:57:58 Voltage Offset Correction: v_off_ini = -0.000000840 V, v_off_fin = 0.000002079 V 19:57:58 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143393261 Vs 19:57:58 Integrated Voltage Measurement... 19:58:31 Voltage Offset Correction: v_off_ini = 0.000000808 V, v_off_fin = -0.000003366 V 19:58:31 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143350079 Vs 19:58:32   Voltage Measurement, V = 0.000000 V 19:58:32 Temperature Measurement, Probe Number = 0, T = 21.386000 C 19:58:33 Temperature Measurement, Probe Number = 1, T = 22.461000 C 19:58:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.39 P2 = 3458_Meas_Junction, Value = 22.46 19:58:33 Integrated Voltage Measurement... 19:59:04 Voltage Offset Correction: v_off_ini = -0.000000931 V, v_off_fin = 0.000000704 V 19:59:04 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143392848 Vs 19:59:04 Integrated Voltage Measurement... 19:59:34 Voltage Offset Correction: v_off_ini = 0.000000667 V, v_off_fin = -0.000001576 V 19:59:34 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143350936 Vs