SLAC Magnetic Measurements Date: 11-18-2020 Time: 16:46:02 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_014_Cell_46 Serial Number: PC33408 Run Number: 13 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 13 16:46:20 Ambient Measurement Device(s) Being Used, type = None 16:46:20 Magnet Voltage Measurement Device(s) Being Used, type = None 16:46:20 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 16:46:20 XMAG Device(s) Being Used, type = None 16:46:20 Ambient Measurement Device(s) Being Used, type = None 16:46:24   Voltage Measurement, V = 0.000000 V 16:46:25 Temperature Measurement, Probe Number = 0, T = 21.581000 C 16:46:26 Temperature Measurement, Probe Number = 1, T = 22.181000 C 16:46:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.58 P2 = 3458_Meas_Junction, Value = 22.18 16:46:26 Integrated Voltage Measurement... 16:46:54 Voltage Offset Correction: v_off_ini = -0.000000367 V, v_off_fin = 0.000001304 V 16:46:54 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.143343013 Vs 16:46:54 Integrated Voltage Measurement... 16:47:25 Voltage Offset Correction: v_off_ini = 0.000000109 V, v_off_fin = -0.000003959 V 16:47:25 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143305823 Vs 16:47:26   Voltage Measurement, V = 0.000000 V 16:47:27 Temperature Measurement, Probe Number = 0, T = 21.573000 C 16:47:27 Temperature Measurement, Probe Number = 1, T = 22.180000 C 16:47:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.57 P2 = 3458_Meas_Junction, Value = 22.18 16:47:27 Integrated Voltage Measurement... 16:47:58 Voltage Offset Correction: v_off_ini = -0.000001669 V, v_off_fin = 0.000001400 V 16:47:58 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143337526 Vs 16:47:58 Integrated Voltage Measurement... 16:48:35 Voltage Offset Correction: v_off_ini = 0.000000134 V, v_off_fin = -0.000003079 V 16:48:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143307871 Vs 16:48:36   Voltage Measurement, V = 0.000000 V 16:48:37 Temperature Measurement, Probe Number = 0, T = 21.600000 C 16:48:37 Temperature Measurement, Probe Number = 1, T = 22.198000 C 16:48:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.60 P2 = 3458_Meas_Junction, Value = 22.20 16:48:37 Integrated Voltage Measurement... 16:49:09 Voltage Offset Correction: v_off_ini = -0.000001329 V, v_off_fin = 0.000000398 V 16:49:09 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143338630 Vs 16:49:09 Integrated Voltage Measurement... 16:49:44 Voltage Offset Correction: v_off_ini = -0.000000061 V, v_off_fin = -0.000003743 V 16:49:44 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143296252 Vs 16:49:45   Voltage Measurement, V = 0.000000 V 16:49:46 Temperature Measurement, Probe Number = 0, T = 21.593000 C 16:49:46 Temperature Measurement, Probe Number = 1, T = 22.203000 C 16:49:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.59 P2 = 3458_Meas_Junction, Value = 22.20 16:49:46 Integrated Voltage Measurement... 16:50:16 Voltage Offset Correction: v_off_ini = -0.000001403 V, v_off_fin = -0.000000205 V 16:50:16 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143323670 Vs 16:50:16 Integrated Voltage Measurement... 16:50:47 Voltage Offset Correction: v_off_ini = 0.000000106 V, v_off_fin = -0.000001635 V 16:50:47 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143303129 Vs 16:50:48   Voltage Measurement, V = 0.000000 V 16:50:49 Temperature Measurement, Probe Number = 0, T = 21.580000 C 16:50:50 Temperature Measurement, Probe Number = 1, T = 22.211000 C 16:50:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.58 P2 = 3458_Meas_Junction, Value = 22.21 16:50:50 Integrated Voltage Measurement... 16:51:20 Voltage Offset Correction: v_off_ini = -0.000001606 V, v_off_fin = -0.000000267 V 16:51:20 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143336057 Vs 16:51:20 Integrated Voltage Measurement... 16:51:50 Voltage Offset Correction: v_off_ini = 0.000000068 V, v_off_fin = -0.000003018 V 16:51:50 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143293397 Vs 16:51:51   Voltage Measurement, V = 0.000000 V 16:51:51 Temperature Measurement, Probe Number = 0, T = 21.571000 C 16:51:52 Temperature Measurement, Probe Number = 1, T = 22.210000 C 16:51:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.57 P2 = 3458_Meas_Junction, Value = 22.21 16:51:52 Integrated Voltage Measurement... 16:52:26 Voltage Offset Correction: v_off_ini = -0.000001311 V, v_off_fin = 0.000000965 V 16:52:26 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143338252 Vs 16:52:26 Integrated Voltage Measurement... 16:52:58 Voltage Offset Correction: v_off_ini = 0.000000064 V, v_off_fin = -0.000003022 V 16:52:58 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143297635 Vs 16:52:59   Voltage Measurement, V = 0.000000 V 16:53:00 Temperature Measurement, Probe Number = 0, T = 21.567000 C 16:53:01 Temperature Measurement, Probe Number = 1, T = 22.211000 C 16:53:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.57 P2 = 3458_Meas_Junction, Value = 22.21 16:53:01 Integrated Voltage Measurement... 16:53:32 Voltage Offset Correction: v_off_ini = -0.000001790 V, v_off_fin = -0.000000950 V 16:53:32 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143334686 Vs 16:53:32 Integrated Voltage Measurement... 16:54:16 Voltage Offset Correction: v_off_ini = 0.000000115 V, v_off_fin = -0.000003471 V 16:54:16 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143300899 Vs 16:54:17   Voltage Measurement, V = 0.000000 V 16:54:18 Temperature Measurement, Probe Number = 0, T = 21.557000 C 16:54:18 Temperature Measurement, Probe Number = 1, T = 22.223000 C 16:54:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.56 P2 = 3458_Meas_Junction, Value = 22.22 16:54:18 Integrated Voltage Measurement... 16:54:49 Voltage Offset Correction: v_off_ini = -0.000001230 V, v_off_fin = 0.000000794 V 16:54:50 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143327781 Vs 16:54:50 Integrated Voltage Measurement... 16:55:20 Voltage Offset Correction: v_off_ini = 0.000000077 V, v_off_fin = -0.000003194 V 16:55:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143299429 Vs 16:55:21   Voltage Measurement, V = 0.000000 V 16:55:21 Temperature Measurement, Probe Number = 0, T = 21.553000 C 16:55:22 Temperature Measurement, Probe Number = 1, T = 22.230000 C 16:55:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.55 P2 = 3458_Meas_Junction, Value = 22.23 16:55:22 Integrated Voltage Measurement... 16:55:53 Voltage Offset Correction: v_off_ini = -0.000001580 V, v_off_fin = 0.000000532 V 16:55:53 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143340870 Vs 16:55:53 Integrated Voltage Measurement... 16:56:24 Voltage Offset Correction: v_off_ini = 0.000000015 V, v_off_fin = -0.000003743 V 16:56:24 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143300344 Vs 16:56:25   Voltage Measurement, V = 0.000000 V 16:56:25 Temperature Measurement, Probe Number = 0, T = 21.550000 C 16:56:26 Temperature Measurement, Probe Number = 1, T = 22.225000 C 16:56:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.55 P2 = 3458_Meas_Junction, Value = 22.23 16:56:26 Integrated Voltage Measurement... 16:56:57 Voltage Offset Correction: v_off_ini = -0.000001513 V, v_off_fin = 0.000000129 V 16:56:57 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143336216 Vs 16:56:57 Integrated Voltage Measurement... 16:57:31 Voltage Offset Correction: v_off_ini = -0.000000062 V, v_off_fin = -0.000003649 V 16:57:31 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143297553 Vs