SLAC Magnetic Measurements Date: 10-29-2020 Time: 16:38:49 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_014_Cell_46 Serial Number: PC33408 Run Number: 12 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 12 16:39:07 Ambient Measurement Device(s) Being Used, type = None 16:39:07 Magnet Voltage Measurement Device(s) Being Used, type = None 16:39:07 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 16:39:07 XMAG Device(s) Being Used, type = None 16:39:07 Ambient Measurement Device(s) Being Used, type = None 16:39:11   Voltage Measurement, V = 0.000000 V 16:39:12 Temperature Measurement, Probe Number = 0, T = 21.772000 C 16:39:13 Temperature Measurement, Probe Number = 1, T = 22.615000 C 16:39:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.77 P2 = 3458_Meas_Junction, Value = 22.61 16:39:13 Integrated Voltage Measurement... 16:39:39 Voltage Offset Correction: v_off_ini = 0.000000320 V, v_off_fin = 0.000002468 V 16:39:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143487189 Vs 16:39:39 Integrated Voltage Measurement... 16:40:14 Voltage Offset Correction: v_off_ini = 0.000000904 V, v_off_fin = -0.000001978 V 16:40:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143456579 Vs 16:40:15   Voltage Measurement, V = 0.000000 V 16:40:16 Temperature Measurement, Probe Number = 0, T = 21.736000 C 16:40:16 Temperature Measurement, Probe Number = 1, T = 22.629000 C 16:40:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.74 P2 = 3458_Meas_Junction, Value = 22.63 16:40:16 Integrated Voltage Measurement... 16:40:48 Voltage Offset Correction: v_off_ini = -0.000000965 V, v_off_fin = 0.000000814 V 16:40:48 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.143504171 Vs 16:40:48 Integrated Voltage Measurement... 16:41:19 Voltage Offset Correction: v_off_ini = 0.000000945 V, v_off_fin = -0.000002650 V 16:41:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143462871 Vs 16:41:20   Voltage Measurement, V = 0.000000 V 16:41:20 Temperature Measurement, Probe Number = 0, T = 21.725000 C 16:41:21 Temperature Measurement, Probe Number = 1, T = 22.638000 C 16:41:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.73 P2 = 3458_Meas_Junction, Value = 22.64 16:41:21 Integrated Voltage Measurement... 16:41:52 Voltage Offset Correction: v_off_ini = -0.000000598 V, v_off_fin = 0.000002516 V 16:41:52 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143496872 Vs 16:41:52 Integrated Voltage Measurement... 16:42:22 Voltage Offset Correction: v_off_ini = 0.000000814 V, v_off_fin = -0.000002929 V 16:42:22 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143463045 Vs 16:42:23   Voltage Measurement, V = 0.000000 V 16:42:24 Temperature Measurement, Probe Number = 0, T = 21.729000 C 16:42:25 Temperature Measurement, Probe Number = 1, T = 22.636000 C 16:42:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.73 P2 = 3458_Meas_Junction, Value = 22.64 16:42:25 Integrated Voltage Measurement... 16:42:55 Voltage Offset Correction: v_off_ini = -0.000001120 V, v_off_fin = 0.000001153 V 16:42:55 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.143502961 Vs 16:42:55 Integrated Voltage Measurement... 16:43:26 Voltage Offset Correction: v_off_ini = 0.000000937 V, v_off_fin = -0.000002570 V 16:43:26 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143460749 Vs 16:43:27   Voltage Measurement, V = 0.000000 V 16:43:27 Temperature Measurement, Probe Number = 0, T = 21.728000 C 16:43:28 Temperature Measurement, Probe Number = 1, T = 22.646000 C 16:43:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.73 P2 = 3458_Meas_Junction, Value = 22.65 16:43:28 Integrated Voltage Measurement... 16:43:58 Voltage Offset Correction: v_off_ini = -0.000000713 V, v_off_fin = 0.000000838 V 16:43:58 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143490905 Vs 16:43:58 Integrated Voltage Measurement... 16:44:29 Voltage Offset Correction: v_off_ini = 0.000000617 V, v_off_fin = -0.000003665 V 16:44:29 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143456986 Vs 16:44:30   Voltage Measurement, V = 0.000000 V 16:44:31 Temperature Measurement, Probe Number = 0, T = 21.735000 C 16:44:31 Temperature Measurement, Probe Number = 1, T = 22.665000 C 16:44:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.73 P2 = 3458_Meas_Junction, Value = 22.66 16:44:31 Integrated Voltage Measurement... 16:45:03 Voltage Offset Correction: v_off_ini = -0.000000934 V, v_off_fin = 0.000001985 V 16:45:03 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.143497794 Vs 16:45:03 Integrated Voltage Measurement... 16:45:34 Voltage Offset Correction: v_off_ini = 0.000000753 V, v_off_fin = -0.000001995 V 16:45:34 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143436483 Vs 16:45:35   Voltage Measurement, V = 0.000000 V 16:45:35 Temperature Measurement, Probe Number = 0, T = 21.728000 C 16:45:36 Temperature Measurement, Probe Number = 1, T = 22.673000 C 16:45:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.73 P2 = 3458_Meas_Junction, Value = 22.67 16:45:36 Integrated Voltage Measurement... 16:46:06 Voltage Offset Correction: v_off_ini = -0.000001125 V, v_off_fin = 0.000001331 V 16:46:07 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143484805 Vs 16:46:07 Integrated Voltage Measurement... 16:46:36 Voltage Offset Correction: v_off_ini = 0.000000932 V, v_off_fin = -0.000002837 V 16:46:36 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143451299 Vs 16:46:37   Voltage Measurement, V = 0.000000 V 16:46:38 Temperature Measurement, Probe Number = 0, T = 21.726000 C 16:46:39 Temperature Measurement, Probe Number = 1, T = 22.663000 C 16:46:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.73 P2 = 3458_Meas_Junction, Value = 22.66 16:46:39 Integrated Voltage Measurement... 16:47:09 Voltage Offset Correction: v_off_ini = -0.000000914 V, v_off_fin = 0.000001737 V 16:47:09 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143486768 Vs 16:47:09 Integrated Voltage Measurement... 16:47:40 Voltage Offset Correction: v_off_ini = 0.000000516 V, v_off_fin = -0.000003673 V 16:47:40 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143454390 Vs 16:47:41   Voltage Measurement, V = 0.000000 V 16:47:42 Temperature Measurement, Probe Number = 0, T = 21.727000 C 16:47:42 Temperature Measurement, Probe Number = 1, T = 22.674000 C 16:47:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.73 P2 = 3458_Meas_Junction, Value = 22.67 16:47:42 Integrated Voltage Measurement... 16:48:13 Voltage Offset Correction: v_off_ini = -0.000000974 V, v_off_fin = 0.000001120 V 16:48:13 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.143494945 Vs 16:48:13 Integrated Voltage Measurement... 16:48:47 Voltage Offset Correction: v_off_ini = 0.000000917 V, v_off_fin = -0.000002178 V 16:48:47 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143463334 Vs 16:48:48   Voltage Measurement, V = 0.000000 V 16:48:48 Temperature Measurement, Probe Number = 0, T = 21.721000 C 16:48:49 Temperature Measurement, Probe Number = 1, T = 22.682000 C 16:48:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.72 P2 = 3458_Meas_Junction, Value = 22.68 16:48:49 Integrated Voltage Measurement... 16:49:20 Voltage Offset Correction: v_off_ini = -0.000000863 V, v_off_fin = 0.000001896 V 16:49:20 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.143493586 Vs 16:49:20 Integrated Voltage Measurement... 16:49:51 Voltage Offset Correction: v_off_ini = 0.000000641 V, v_off_fin = -0.000002893 V 16:49:51 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143452614 Vs