SLAC Magnetic Measurements Date: 10-21-2020 Time: 15:12:27 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_014_Cell_46 Serial Number: PC33408 Run Number: 11 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 11 15:12:45 Ambient Measurement Device(s) Being Used, type = None 15:12:45 Magnet Voltage Measurement Device(s) Being Used, type = None 15:12:45 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:12:45 XMAG Device(s) Being Used, type = None 15:12:45 Ambient Measurement Device(s) Being Used, type = None 15:12:50   Voltage Measurement, V = 0.000000 V 15:12:51 Temperature Measurement, Probe Number = 0, T = 21.762000 C 15:12:52 Temperature Measurement, Probe Number = 1, T = 20.617000 C 15:12:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.76 P2 = 3458_Meas_Junction, Value = 20.62 15:12:52 Integrated Voltage Measurement... 15:13:18 Voltage Offset Correction: v_off_ini = -0.000000374 V, v_off_fin = 0.000001854 V 15:13:18 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.143527622 Vs 15:13:18 Integrated Voltage Measurement... 15:13:48 Voltage Offset Correction: v_off_ini = 0.000000092 V, v_off_fin = -0.000003792 V 15:13:48 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143485375 Vs 15:13:49   Voltage Measurement, V = 0.000000 V 15:13:50 Temperature Measurement, Probe Number = 0, T = 21.754000 C 15:13:50 Temperature Measurement, Probe Number = 1, T = 20.637000 C 15:13:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.75 P2 = 3458_Meas_Junction, Value = 20.64 15:13:51 Integrated Voltage Measurement... 15:14:22 Voltage Offset Correction: v_off_ini = -0.000001775 V, v_off_fin = 0.000000955 V 15:14:22 Integrated Voltage Measurement Delta Gap = -0.0000001 m VT = 0.143515699 Vs 15:14:22 Integrated Voltage Measurement... 15:16:36 Voltage Offset Correction: v_off_ini = -0.000000583 V, v_off_fin = -0.000003235 V 15:16:36 Integrated Voltage Measurement Delta Gap = -0.0040014 m VT = -0.143499996 Vs 15:16:37   Voltage Measurement, V = 0.000000 V 15:16:38 Temperature Measurement, Probe Number = 0, T = 21.738000 C 15:16:38 Temperature Measurement, Probe Number = 1, T = 20.652000 C 15:16:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.74 P2 = 3458_Meas_Junction, Value = 20.65 15:16:38 Integrated Voltage Measurement... 15:17:10 Voltage Offset Correction: v_off_ini = -0.000001117 V, v_off_fin = 0.000000760 V 15:17:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143524173 Vs 15:17:10 Integrated Voltage Measurement... 15:17:49 Voltage Offset Correction: v_off_ini = -0.000000034 V, v_off_fin = -0.000001276 V 15:17:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143487633 Vs 15:17:50   Voltage Measurement, V = 0.000000 V 15:17:50 Temperature Measurement, Probe Number = 0, T = 21.745000 C 15:17:51 Temperature Measurement, Probe Number = 1, T = 20.660000 C 15:17:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.75 P2 = 3458_Meas_Junction, Value = 20.66 15:17:51 Integrated Voltage Measurement... 15:18:23 Voltage Offset Correction: v_off_ini = -0.000001575 V, v_off_fin = -0.000000169 V 15:18:23 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143517625 Vs 15:18:23 Integrated Voltage Measurement... 15:18:55 Voltage Offset Correction: v_off_ini = 0.000000479 V, v_off_fin = -0.000002252 V 15:18:55 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143491409 Vs 15:18:56   Voltage Measurement, V = 0.000000 V 15:18:57 Temperature Measurement, Probe Number = 0, T = 21.750000 C 15:18:57 Temperature Measurement, Probe Number = 1, T = 20.661000 C 15:18:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.75 P2 = 3458_Meas_Junction, Value = 20.66 15:18:57 Integrated Voltage Measurement... 15:19:28 Voltage Offset Correction: v_off_ini = -0.000001383 V, v_off_fin = 0.000001095 V 15:19:28 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.143541659 Vs 15:19:28 Integrated Voltage Measurement... 15:20:01 Voltage Offset Correction: v_off_ini = -0.000000134 V, v_off_fin = -0.000003325 V 15:20:01 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143488076 Vs 15:20:02   Voltage Measurement, V = 0.000000 V 15:20:02 Temperature Measurement, Probe Number = 0, T = 21.755000 C 15:20:03 Temperature Measurement, Probe Number = 1, T = 20.659000 C 15:20:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.75 P2 = 3458_Meas_Junction, Value = 20.66 15:20:03 Integrated Voltage Measurement... 15:20:35 Voltage Offset Correction: v_off_ini = -0.000001487 V, v_off_fin = 0.000000412 V 15:20:35 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143518853 Vs 15:20:35 Integrated Voltage Measurement... 15:21:10 Voltage Offset Correction: v_off_ini = 0.000000042 V, v_off_fin = -0.000002744 V 15:21:10 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143486426 Vs 15:21:11   Voltage Measurement, V = 0.000000 V 15:21:12 Temperature Measurement, Probe Number = 0, T = 21.759000 C 15:21:12 Temperature Measurement, Probe Number = 1, T = 20.653000 C 15:21:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.76 P2 = 3458_Meas_Junction, Value = 20.65 15:21:12 Integrated Voltage Measurement... 15:21:44 Voltage Offset Correction: v_off_ini = -0.000001321 V, v_off_fin = 0.000000013 V 15:21:44 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143514511 Vs 15:21:44 Integrated Voltage Measurement... 15:22:16 Voltage Offset Correction: v_off_ini = 0.000000059 V, v_off_fin = -0.000003149 V 15:22:16 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143492246 Vs 15:22:17   Voltage Measurement, V = 0.000000 V 15:22:17 Temperature Measurement, Probe Number = 0, T = 21.760000 C 15:22:18 Temperature Measurement, Probe Number = 1, T = 20.649000 C 15:22:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.76 P2 = 3458_Meas_Junction, Value = 20.65 15:22:18 Integrated Voltage Measurement... 15:22:51 Voltage Offset Correction: v_off_ini = -0.000001383 V, v_off_fin = 0.000000059 V 15:22:51 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.143532002 Vs 15:22:51 Integrated Voltage Measurement... 15:23:21 Voltage Offset Correction: v_off_ini = 0.000000179 V, v_off_fin = -0.000003039 V 15:23:21 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143494353 Vs 15:23:22   Voltage Measurement, V = 0.000000 V 15:23:23 Temperature Measurement, Probe Number = 0, T = 21.759000 C 15:23:23 Temperature Measurement, Probe Number = 1, T = 20.650000 C 15:23:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.76 P2 = 3458_Meas_Junction, Value = 20.65 15:23:23 Integrated Voltage Measurement... 15:23:56 Voltage Offset Correction: v_off_ini = -0.000001286 V, v_off_fin = 0.000000302 V 15:23:56 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143532391 Vs 15:23:56 Integrated Voltage Measurement... 15:24:27 Voltage Offset Correction: v_off_ini = -0.000000067 V, v_off_fin = -0.000003830 V 15:24:27 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143480536 Vs 15:24:28   Voltage Measurement, V = 0.000000 V 15:24:28 Temperature Measurement, Probe Number = 0, T = 21.757000 C 15:24:29 Temperature Measurement, Probe Number = 1, T = 20.646000 C 15:24:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.76 P2 = 3458_Meas_Junction, Value = 20.65 15:24:29 Integrated Voltage Measurement... 15:25:01 Voltage Offset Correction: v_off_ini = -0.000001483 V, v_off_fin = 0.000000789 V 15:25:01 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143528861 Vs 15:25:01 Integrated Voltage Measurement... 15:25:42 Voltage Offset Correction: v_off_ini = -0.000000020 V, v_off_fin = -0.000002778 V 15:25:42 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.143478366 Vs