SLAC Magnetic Measurements Date: 01-08-2021 Time: 11:42:16 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_013_Cell_44 Serial Number: PC33408 Run Number: 15 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 15 11:42:34 Ambient Measurement Device(s) Being Used, type = None 11:42:34 Magnet Voltage Measurement Device(s) Being Used, type = None 11:42:35 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 11:42:35 XMAG Device(s) Being Used, type = None 11:42:35 Ambient Measurement Device(s) Being Used, type = None 11:42:45   Voltage Measurement, V = 0.000000 V 11:42:45 Temperature Measurement, Probe Number = 0, T = 21.095000 C 11:42:46 Temperature Measurement, Probe Number = 1, T = 22.079000 C 11:42:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.09 P2 = 3458_Meas_Junction, Value = 22.08 11:42:46 Integrated Voltage Measurement... 11:43:13 Voltage Offset Correction: v_off_ini = 0.000000248 V, v_off_fin = 0.000000673 V 11:43:13 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143122136 Vs 11:43:13 Integrated Voltage Measurement... 11:43:43 Voltage Offset Correction: v_off_ini = 0.000000672 V, v_off_fin = -0.000001639 V 11:43:43 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143083906 Vs 11:43:44   Voltage Measurement, V = 0.000000 V 11:43:45 Temperature Measurement, Probe Number = 0, T = 21.082000 C 11:43:46 Temperature Measurement, Probe Number = 1, T = 22.111000 C 11:43:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.08 P2 = 3458_Meas_Junction, Value = 22.11 11:43:46 Integrated Voltage Measurement... 11:44:17 Voltage Offset Correction: v_off_ini = -0.000000937 V, v_off_fin = 0.000000856 V 11:44:17 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143123179 Vs 11:44:17 Integrated Voltage Measurement... 11:44:47 Voltage Offset Correction: v_off_ini = 0.000000850 V, v_off_fin = -0.000002213 V 11:44:48 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143099273 Vs 11:44:49   Voltage Measurement, V = 0.000000 V 11:44:49 Temperature Measurement, Probe Number = 0, T = 21.098000 C 11:44:50 Temperature Measurement, Probe Number = 1, T = 22.128000 C 11:44:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.10 P2 = 3458_Meas_Junction, Value = 22.13 11:44:50 Integrated Voltage Measurement... 11:45:21 Voltage Offset Correction: v_off_ini = -0.000000914 V, v_off_fin = 0.000000633 V 11:45:22 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143133120 Vs 11:45:22 Integrated Voltage Measurement... 11:45:54 Voltage Offset Correction: v_off_ini = 0.000000735 V, v_off_fin = -0.000002769 V 11:45:54 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143101013 Vs 11:45:55   Voltage Measurement, V = 0.000000 V 11:45:55 Temperature Measurement, Probe Number = 0, T = 21.113000 C 11:45:56 Temperature Measurement, Probe Number = 1, T = 22.148000 C 11:45:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.11 P2 = 3458_Meas_Junction, Value = 22.15 11:45:56 Integrated Voltage Measurement... 11:46:27 Voltage Offset Correction: v_off_ini = -0.000000759 V, v_off_fin = 0.000001319 V 11:46:27 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143132958 Vs 11:46:27 Integrated Voltage Measurement... 11:46:58 Voltage Offset Correction: v_off_ini = 0.000000893 V, v_off_fin = -0.000001980 V 11:46:58 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143099424 Vs 11:46:59   Voltage Measurement, V = 0.000000 V 11:47:00 Temperature Measurement, Probe Number = 0, T = 21.130000 C 11:47:00 Temperature Measurement, Probe Number = 1, T = 22.162000 C 11:47:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.13 P2 = 3458_Meas_Junction, Value = 22.16 11:47:00 Integrated Voltage Measurement... 11:47:32 Voltage Offset Correction: v_off_ini = -0.000000630 V, v_off_fin = 0.000000970 V 11:47:32 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143133236 Vs 11:47:32 Integrated Voltage Measurement... 11:48:02 Voltage Offset Correction: v_off_ini = 0.000000958 V, v_off_fin = -0.000002381 V 11:48:02 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143098011 Vs 11:48:03   Voltage Measurement, V = 0.000000 V 11:48:04 Temperature Measurement, Probe Number = 0, T = 21.147000 C 11:48:05 Temperature Measurement, Probe Number = 1, T = 22.181000 C 11:48:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.15 P2 = 3458_Meas_Junction, Value = 22.18 11:48:05 Integrated Voltage Measurement... 11:48:36 Voltage Offset Correction: v_off_ini = -0.000000949 V, v_off_fin = 0.000000834 V 11:48:36 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143121105 Vs 11:48:36 Integrated Voltage Measurement... 11:49:07 Voltage Offset Correction: v_off_ini = 0.000000704 V, v_off_fin = -0.000001302 V 11:49:07 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143099248 Vs 11:49:08   Voltage Measurement, V = 0.000000 V 11:49:09 Temperature Measurement, Probe Number = 0, T = 21.158000 C 11:49:09 Temperature Measurement, Probe Number = 1, T = 22.188000 C 11:49:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.16 P2 = 3458_Meas_Junction, Value = 22.19 11:49:09 Integrated Voltage Measurement... 11:49:41 Voltage Offset Correction: v_off_ini = -0.000000640 V, v_off_fin = 0.000001129 V 11:49:41 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143120641 Vs 11:49:41 Integrated Voltage Measurement... 11:50:11 Voltage Offset Correction: v_off_ini = 0.000000922 V, v_off_fin = -0.000000848 V 11:50:11 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143089723 Vs 11:50:12   Voltage Measurement, V = 0.000000 V 11:50:13 Temperature Measurement, Probe Number = 0, T = 21.168000 C 11:50:13 Temperature Measurement, Probe Number = 1, T = 22.204000 C 11:50:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.17 P2 = 3458_Meas_Junction, Value = 22.20 11:50:13 Integrated Voltage Measurement... 11:50:44 Voltage Offset Correction: v_off_ini = -0.000000887 V, v_off_fin = 0.000001062 V 11:50:44 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143121975 Vs 11:50:44 Integrated Voltage Measurement... 11:51:14 Voltage Offset Correction: v_off_ini = 0.000000965 V, v_off_fin = -0.000002437 V 11:51:14 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143097436 Vs 11:51:15   Voltage Measurement, V = 0.000000 V 11:51:16 Temperature Measurement, Probe Number = 0, T = 21.172000 C 11:51:17 Temperature Measurement, Probe Number = 1, T = 22.216000 C 11:51:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.17 P2 = 3458_Meas_Junction, Value = 22.22 11:51:17 Integrated Voltage Measurement... 11:51:47 Voltage Offset Correction: v_off_ini = -0.000000727 V, v_off_fin = 0.000002372 V 11:51:47 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143127897 Vs 11:51:47 Integrated Voltage Measurement... 11:52:18 Voltage Offset Correction: v_off_ini = 0.000000514 V, v_off_fin = -0.000003068 V 11:52:18 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143099745 Vs 11:52:19   Voltage Measurement, V = 0.000000 V 11:52:19 Temperature Measurement, Probe Number = 0, T = 21.182000 C 11:52:20 Temperature Measurement, Probe Number = 1, T = 22.225000 C 11:52:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.18 P2 = 3458_Meas_Junction, Value = 22.23 11:52:20 Integrated Voltage Measurement... 11:52:51 Voltage Offset Correction: v_off_ini = -0.000000565 V, v_off_fin = 0.000001174 V 11:52:51 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143118356 Vs 11:52:51 Integrated Voltage Measurement... 11:53:21 Voltage Offset Correction: v_off_ini = 0.000000807 V, v_off_fin = -0.000002622 V 11:53:21 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143093424 Vs