SLAC Magnetic Measurements Date: 12-02-2020 Time: 16:39:58 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_013_Cell_44 Serial Number: PC33408 Run Number: 14 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full set 14 16:40:16 Ambient Measurement Device(s) Being Used, type = None 16:40:16 Magnet Voltage Measurement Device(s) Being Used, type = None 16:40:16 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 16:40:16 XMAG Device(s) Being Used, type = None 16:40:16 Ambient Measurement Device(s) Being Used, type = None 16:40:21   Voltage Measurement, V = 0.000000 V 16:40:22 Temperature Measurement, Probe Number = 0, T = 21.392000 C 16:40:23 Temperature Measurement, Probe Number = 1, T = 20.271000 C 16:40:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.39 P2 = 3458_Meas_Junction, Value = 20.27 16:40:23 Integrated Voltage Measurement... 16:40:49 Voltage Offset Correction: v_off_ini = 0.000000517 V, v_off_fin = 0.000001909 V 16:40:49 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143101306 Vs 16:40:49 Integrated Voltage Measurement... 16:41:19 Voltage Offset Correction: v_off_ini = 0.000001146 V, v_off_fin = -0.000001976 V 16:41:19 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143077567 Vs 16:41:20   Voltage Measurement, V = 0.000000 V 16:41:21 Temperature Measurement, Probe Number = 0, T = 21.388000 C 16:41:21 Temperature Measurement, Probe Number = 1, T = 20.229000 C 16:41:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.39 P2 = 3458_Meas_Junction, Value = 20.23 16:41:21 Integrated Voltage Measurement... 16:41:53 Voltage Offset Correction: v_off_ini = -0.000000635 V, v_off_fin = 0.000001149 V 16:41:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143113300 Vs 16:41:53 Integrated Voltage Measurement... 16:42:24 Voltage Offset Correction: v_off_ini = 0.000001249 V, v_off_fin = -0.000001352 V 16:42:24 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.143079450 Vs 16:42:25   Voltage Measurement, V = 0.000000 V 16:42:25 Temperature Measurement, Probe Number = 0, T = 21.389000 C 16:42:26 Temperature Measurement, Probe Number = 1, T = 20.238000 C 16:42:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.39 P2 = 3458_Meas_Junction, Value = 20.24 16:42:26 Integrated Voltage Measurement... 16:42:56 Voltage Offset Correction: v_off_ini = -0.000000455 V, v_off_fin = 0.000001544 V 16:42:56 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143119344 Vs 16:42:56 Integrated Voltage Measurement... 16:43:28 Voltage Offset Correction: v_off_ini = 0.000000906 V, v_off_fin = -0.000002214 V 16:43:28 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143080516 Vs 16:43:29   Voltage Measurement, V = 0.000000 V 16:43:30 Temperature Measurement, Probe Number = 0, T = 21.405000 C 16:43:31 Temperature Measurement, Probe Number = 1, T = 20.245000 C 16:43:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.41 P2 = 3458_Meas_Junction, Value = 20.25 16:43:31 Integrated Voltage Measurement... 16:44:03 Voltage Offset Correction: v_off_ini = -0.000000427 V, v_off_fin = 0.000002333 V 16:44:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143106561 Vs 16:44:03 Integrated Voltage Measurement... 16:44:35 Voltage Offset Correction: v_off_ini = 0.000000966 V, v_off_fin = -0.000001177 V 16:44:35 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.143084641 Vs 16:44:36   Voltage Measurement, V = 0.000000 V 16:44:37 Temperature Measurement, Probe Number = 0, T = 21.410000 C 16:44:38 Temperature Measurement, Probe Number = 1, T = 20.243000 C 16:44:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.41 P2 = 3458_Meas_Junction, Value = 20.24 16:44:38 Integrated Voltage Measurement... 16:45:09 Voltage Offset Correction: v_off_ini = -0.000000844 V, v_off_fin = 0.000000976 V 16:45:09 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143102582 Vs 16:45:09 Integrated Voltage Measurement... 16:45:48 Voltage Offset Correction: v_off_ini = 0.000000696 V, v_off_fin = -0.000002207 V 16:45:49 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143076435 Vs 16:45:50   Voltage Measurement, V = 0.000000 V 16:45:50 Temperature Measurement, Probe Number = 0, T = 21.445000 C 16:45:51 Temperature Measurement, Probe Number = 1, T = 22.837000 C 16:45:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.45 P2 = 3458_Meas_Junction, Value = 22.84 16:45:51 Integrated Voltage Measurement... 16:46:25 Voltage Offset Correction: v_off_ini = -0.000000512 V, v_off_fin = 0.000000735 V 16:46:25 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.143116363 Vs 16:46:25 Integrated Voltage Measurement... 16:46:56 Voltage Offset Correction: v_off_ini = 0.000000886 V, v_off_fin = -0.000002838 V 16:46:56 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143076010 Vs 16:46:57   Voltage Measurement, V = 0.000000 V 16:46:58 Temperature Measurement, Probe Number = 0, T = 21.429000 C 16:46:58 Temperature Measurement, Probe Number = 1, T = 23.062000 C 16:46:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.43 P2 = 3458_Meas_Junction, Value = 23.06 16:46:59 Integrated Voltage Measurement... 16:47:38 Voltage Offset Correction: v_off_ini = -0.000000241 V, v_off_fin = 0.000002052 V 16:47:38 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143109033 Vs 16:47:38 Integrated Voltage Measurement... 16:48:09 Voltage Offset Correction: v_off_ini = 0.000000913 V, v_off_fin = -0.000002046 V 16:48:09 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.143078447 Vs 16:48:10   Voltage Measurement, V = 0.000000 V 16:48:11 Temperature Measurement, Probe Number = 0, T = 21.403000 C 16:48:12 Temperature Measurement, Probe Number = 1, T = 23.085000 C 16:48:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.40 P2 = 3458_Meas_Junction, Value = 23.09 16:48:12 Integrated Voltage Measurement... 16:48:44 Voltage Offset Correction: v_off_ini = -0.000000520 V, v_off_fin = 0.000001572 V 16:48:44 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.143109493 Vs 16:48:44 Integrated Voltage Measurement... 16:49:18 Voltage Offset Correction: v_off_ini = 0.000000959 V, v_off_fin = -0.000001726 V 16:49:18 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.143081385 Vs 16:49:19   Voltage Measurement, V = 0.000000 V 16:49:20 Temperature Measurement, Probe Number = 0, T = 21.397000 C 16:49:20 Temperature Measurement, Probe Number = 1, T = 23.093000 C 16:49:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.40 P2 = 3458_Meas_Junction, Value = 23.09 16:49:20 Integrated Voltage Measurement... 16:49:53 Voltage Offset Correction: v_off_ini = -0.000000383 V, v_off_fin = 0.000001460 V 16:49:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143104560 Vs 16:49:53 Integrated Voltage Measurement... 16:50:24 Voltage Offset Correction: v_off_ini = 0.000001029 V, v_off_fin = -0.000002262 V 16:50:25 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143081727 Vs 16:50:26   Voltage Measurement, V = 0.000000 V 16:50:26 Temperature Measurement, Probe Number = 0, T = 21.387000 C 16:50:27 Temperature Measurement, Probe Number = 1, T = 23.101000 C 16:50:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.39 P2 = 3458_Meas_Junction, Value = 23.10 16:50:27 Integrated Voltage Measurement... 16:50:59 Voltage Offset Correction: v_off_ini = -0.000000453 V, v_off_fin = 0.000001672 V 16:50:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143110762 Vs 16:50:59 Integrated Voltage Measurement... 16:51:30 Voltage Offset Correction: v_off_ini = 0.000001108 V, v_off_fin = -0.000001812 V 16:51:30 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.143077909 Vs