SLAC Magnetic Measurements Date: 11-18-2020 Time: 16:17:31 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_013_Cell_44 Serial Number: PC33408 Run Number: 13 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 13 16:17:49 Ambient Measurement Device(s) Being Used, type = None 16:17:49 Magnet Voltage Measurement Device(s) Being Used, type = None 16:17:49 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 16:17:49 XMAG Device(s) Being Used, type = None 16:17:49 Ambient Measurement Device(s) Being Used, type = None 16:17:54   Voltage Measurement, V = 0.000000 V 16:17:55 Temperature Measurement, Probe Number = 0, T = 21.573000 C 16:17:55 Temperature Measurement, Probe Number = 1, T = 22.053000 C 16:17:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.57 P2 = 3458_Meas_Junction, Value = 22.05 16:17:55 Integrated Voltage Measurement... 16:18:21 Voltage Offset Correction: v_off_ini = -0.000000479 V, v_off_fin = 0.000001210 V 16:18:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143159459 Vs 16:18:21 Integrated Voltage Measurement... 16:18:56 Voltage Offset Correction: v_off_ini = 0.000000235 V, v_off_fin = -0.000002014 V 16:18:56 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143138782 Vs 16:18:57   Voltage Measurement, V = 0.000000 V 16:18:58 Temperature Measurement, Probe Number = 0, T = 21.554000 C 16:18:58 Temperature Measurement, Probe Number = 1, T = 22.055000 C 16:18:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.55 P2 = 3458_Meas_Junction, Value = 22.05 16:18:59 Integrated Voltage Measurement... 16:19:29 Voltage Offset Correction: v_off_ini = -0.000001448 V, v_off_fin = 0.000000515 V 16:19:29 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143156436 Vs 16:19:29 Integrated Voltage Measurement... 16:20:02 Voltage Offset Correction: v_off_ini = 0.000000145 V, v_off_fin = -0.000002464 V 16:20:02 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.143145843 Vs 16:20:03   Voltage Measurement, V = 0.000000 V 16:20:04 Temperature Measurement, Probe Number = 0, T = 21.554000 C 16:20:04 Temperature Measurement, Probe Number = 1, T = 22.065000 C 16:20:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.55 P2 = 3458_Meas_Junction, Value = 22.07 16:20:04 Integrated Voltage Measurement... 16:20:36 Voltage Offset Correction: v_off_ini = -0.000001445 V, v_off_fin = 0.000000849 V 16:20:36 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143162115 Vs 16:20:36 Integrated Voltage Measurement... 16:21:07 Voltage Offset Correction: v_off_ini = 0.000000121 V, v_off_fin = -0.000001446 V 16:21:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143126948 Vs 16:21:08   Voltage Measurement, V = 0.000000 V 16:21:09 Temperature Measurement, Probe Number = 0, T = 21.548000 C 16:21:10 Temperature Measurement, Probe Number = 1, T = 22.067000 C 16:21:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.55 P2 = 3458_Meas_Junction, Value = 22.07 16:21:10 Integrated Voltage Measurement... 16:21:40 Voltage Offset Correction: v_off_ini = -0.000001559 V, v_off_fin = 0.000000526 V 16:21:40 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143155655 Vs 16:21:40 Integrated Voltage Measurement... 16:22:11 Voltage Offset Correction: v_off_ini = 0.000000129 V, v_off_fin = -0.000003141 V 16:22:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143123356 Vs 16:22:12   Voltage Measurement, V = 0.000000 V 16:22:13 Temperature Measurement, Probe Number = 0, T = 21.538000 C 16:22:14 Temperature Measurement, Probe Number = 1, T = 22.066000 C 16:22:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.54 P2 = 3458_Meas_Junction, Value = 22.07 16:22:14 Integrated Voltage Measurement... 16:22:46 Voltage Offset Correction: v_off_ini = -0.000001539 V, v_off_fin = 0.000000287 V 16:22:46 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143157551 Vs 16:22:46 Integrated Voltage Measurement... 16:23:20 Voltage Offset Correction: v_off_ini = -0.000000231 V, v_off_fin = -0.000003040 V 16:23:20 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143130193 Vs 16:23:21   Voltage Measurement, V = 0.000000 V 16:23:21 Temperature Measurement, Probe Number = 0, T = 21.525000 C 16:23:22 Temperature Measurement, Probe Number = 1, T = 22.061000 C 16:23:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.52 P2 = 3458_Meas_Junction, Value = 22.06 16:23:22 Integrated Voltage Measurement... 16:23:54 Voltage Offset Correction: v_off_ini = -0.000001532 V, v_off_fin = -0.000000334 V 16:23:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143161697 Vs 16:23:54 Integrated Voltage Measurement... 16:24:25 Voltage Offset Correction: v_off_ini = -0.000000088 V, v_off_fin = -0.000003984 V 16:24:25 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.143137225 Vs 16:24:26   Voltage Measurement, V = 0.000000 V 16:24:27 Temperature Measurement, Probe Number = 0, T = 21.522000 C 16:24:27 Temperature Measurement, Probe Number = 1, T = 22.055000 C 16:24:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.52 P2 = 3458_Meas_Junction, Value = 22.05 16:24:27 Integrated Voltage Measurement... 16:24:58 Voltage Offset Correction: v_off_ini = -0.000001632 V, v_off_fin = 0.000000702 V 16:24:58 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143160927 Vs 16:24:58 Integrated Voltage Measurement... 16:25:30 Voltage Offset Correction: v_off_ini = 0.000000035 V, v_off_fin = -0.000002629 V 16:25:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143118717 Vs 16:25:31   Voltage Measurement, V = 0.000000 V 16:25:32 Temperature Measurement, Probe Number = 0, T = 21.534000 C 16:25:32 Temperature Measurement, Probe Number = 1, T = 22.057000 C 16:25:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.53 P2 = 3458_Meas_Junction, Value = 22.06 16:25:32 Integrated Voltage Measurement... 16:26:03 Voltage Offset Correction: v_off_ini = -0.000001789 V, v_off_fin = 0.000000630 V 16:26:03 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143144710 Vs 16:26:03 Integrated Voltage Measurement... 16:26:35 Voltage Offset Correction: v_off_ini = -0.000000127 V, v_off_fin = -0.000002829 V 16:26:35 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143127024 Vs 16:26:36   Voltage Measurement, V = 0.000000 V 16:26:37 Temperature Measurement, Probe Number = 0, T = 21.548000 C 16:26:37 Temperature Measurement, Probe Number = 1, T = 22.057000 C 16:26:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.55 P2 = 3458_Meas_Junction, Value = 22.06 16:26:37 Integrated Voltage Measurement... 16:27:07 Voltage Offset Correction: v_off_ini = -0.000001725 V, v_off_fin = 0.000001151 V 16:27:07 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143151921 Vs 16:27:07 Integrated Voltage Measurement... 16:27:39 Voltage Offset Correction: v_off_ini = -0.000000061 V, v_off_fin = -0.000003271 V 16:27:39 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143132378 Vs 16:27:40   Voltage Measurement, V = 0.000000 V 16:27:40 Temperature Measurement, Probe Number = 0, T = 21.562000 C 16:27:41 Temperature Measurement, Probe Number = 1, T = 22.059000 C 16:27:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.56 P2 = 3458_Meas_Junction, Value = 22.06 16:27:41 Integrated Voltage Measurement... 16:28:12 Voltage Offset Correction: v_off_ini = -0.000001505 V, v_off_fin = 0.000000310 V 16:28:12 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143171327 Vs 16:28:12 Integrated Voltage Measurement... 16:28:43 Voltage Offset Correction: v_off_ini = -0.000000003 V, v_off_fin = -0.000003526 V 16:28:43 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143115009 Vs