SLAC Magnetic Measurements Date: 10-29-2020 Time: 16:10:57 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_013_Cell_44 Serial Number: PC33408 Run Number: 12 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 12 16:11:15 Ambient Measurement Device(s) Being Used, type = None 16:11:15 Magnet Voltage Measurement Device(s) Being Used, type = None 16:11:15 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 16:11:15 XMAG Device(s) Being Used, type = None 16:11:15 Ambient Measurement Device(s) Being Used, type = None 16:11:20   Voltage Measurement, V = 0.000000 V 16:11:21 Temperature Measurement, Probe Number = 0, T = 21.541000 C 16:11:21 Temperature Measurement, Probe Number = 1, T = 22.387000 C 16:11:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.54 P2 = 3458_Meas_Junction, Value = 22.39 16:11:21 Integrated Voltage Measurement... 16:11:47 Voltage Offset Correction: v_off_ini = 0.000000299 V, v_off_fin = 0.000000398 V 16:11:47 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.143124555 Vs 16:11:47 Integrated Voltage Measurement... 16:12:18 Voltage Offset Correction: v_off_ini = 0.000001009 V, v_off_fin = -0.000001568 V 16:12:18 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143081331 Vs 16:12:19   Voltage Measurement, V = 0.000000 V 16:12:19 Temperature Measurement, Probe Number = 0, T = 21.512000 C 16:12:20 Temperature Measurement, Probe Number = 1, T = 22.436000 C 16:12:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.51 P2 = 3458_Meas_Junction, Value = 22.44 16:12:20 Integrated Voltage Measurement... 16:12:53 Voltage Offset Correction: v_off_ini = -0.000000386 V, v_off_fin = 0.000001660 V 16:12:53 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143100386 Vs 16:12:53 Integrated Voltage Measurement... 16:13:23 Voltage Offset Correction: v_off_ini = 0.000001011 V, v_off_fin = -0.000001720 V 16:13:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143082444 Vs 16:13:24   Voltage Measurement, V = 0.000000 V 16:13:25 Temperature Measurement, Probe Number = 0, T = 21.507000 C 16:13:26 Temperature Measurement, Probe Number = 1, T = 22.475000 C 16:13:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.51 P2 = 3458_Meas_Junction, Value = 22.48 16:13:26 Integrated Voltage Measurement... 16:14:00 Voltage Offset Correction: v_off_ini = -0.000000924 V, v_off_fin = 0.000001557 V 16:14:00 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143100602 Vs 16:14:00 Integrated Voltage Measurement... 16:14:31 Voltage Offset Correction: v_off_ini = 0.000000806 V, v_off_fin = -0.000001825 V 16:14:31 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143083845 Vs 16:14:32   Voltage Measurement, V = 0.000000 V 16:14:33 Temperature Measurement, Probe Number = 0, T = 21.506000 C 16:14:33 Temperature Measurement, Probe Number = 1, T = 22.496000 C 16:14:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.51 P2 = 3458_Meas_Junction, Value = 22.50 16:14:33 Integrated Voltage Measurement... 16:15:04 Voltage Offset Correction: v_off_ini = -0.000000871 V, v_off_fin = 0.000001429 V 16:15:04 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143115223 Vs 16:15:04 Integrated Voltage Measurement... 16:15:36 Voltage Offset Correction: v_off_ini = 0.000000539 V, v_off_fin = -0.000003235 V 16:15:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143073699 Vs 16:15:37   Voltage Measurement, V = 0.000000 V 16:15:37 Temperature Measurement, Probe Number = 0, T = 21.494000 C 16:15:38 Temperature Measurement, Probe Number = 1, T = 22.488000 C 16:15:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.49 P2 = 3458_Meas_Junction, Value = 22.49 16:15:38 Integrated Voltage Measurement... 16:16:09 Voltage Offset Correction: v_off_ini = -0.000000849 V, v_off_fin = 0.000001659 V 16:16:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143120354 Vs 16:16:09 Integrated Voltage Measurement... 16:16:40 Voltage Offset Correction: v_off_ini = 0.000000907 V, v_off_fin = -0.000002564 V 16:16:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143082540 Vs 16:16:41   Voltage Measurement, V = 0.000000 V 16:16:41 Temperature Measurement, Probe Number = 0, T = 21.490000 C 16:16:42 Temperature Measurement, Probe Number = 1, T = 22.499000 C 16:16:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.49 P2 = 3458_Meas_Junction, Value = 22.50 16:16:42 Integrated Voltage Measurement... 16:17:13 Voltage Offset Correction: v_off_ini = -0.000000640 V, v_off_fin = 0.000001887 V 16:17:13 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143117089 Vs 16:17:13 Integrated Voltage Measurement... 16:17:44 Voltage Offset Correction: v_off_ini = 0.000000586 V, v_off_fin = -0.000003204 V 16:17:44 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143090925 Vs 16:17:45   Voltage Measurement, V = 0.000000 V 16:17:46 Temperature Measurement, Probe Number = 0, T = 21.484000 C 16:17:46 Temperature Measurement, Probe Number = 1, T = 22.513000 C 16:17:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.48 P2 = 3458_Meas_Junction, Value = 22.51 16:17:46 Integrated Voltage Measurement... 16:18:18 Voltage Offset Correction: v_off_ini = -0.000000966 V, v_off_fin = 0.000000712 V 16:18:18 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143113422 Vs 16:18:18 Integrated Voltage Measurement... 16:18:49 Voltage Offset Correction: v_off_ini = 0.000000779 V, v_off_fin = -0.000001760 V 16:18:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143085260 Vs 16:18:50   Voltage Measurement, V = 0.000000 V 16:18:51 Temperature Measurement, Probe Number = 0, T = 21.481000 C 16:18:51 Temperature Measurement, Probe Number = 1, T = 22.523000 C 16:18:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.48 P2 = 3458_Meas_Junction, Value = 22.52 16:18:51 Integrated Voltage Measurement... 16:19:24 Voltage Offset Correction: v_off_ini = -0.000000679 V, v_off_fin = 0.000000962 V 16:19:24 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143115973 Vs 16:19:24 Integrated Voltage Measurement... 16:19:56 Voltage Offset Correction: v_off_ini = 0.000000694 V, v_off_fin = -0.000002125 V 16:19:56 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143087450 Vs 16:19:57   Voltage Measurement, V = 0.000000 V 16:19:57 Temperature Measurement, Probe Number = 0, T = 21.488000 C 16:19:58 Temperature Measurement, Probe Number = 1, T = 22.512000 C 16:19:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.49 P2 = 3458_Meas_Junction, Value = 22.51 16:19:58 Integrated Voltage Measurement... 16:20:29 Voltage Offset Correction: v_off_ini = -0.000000813 V, v_off_fin = 0.000000923 V 16:20:29 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143120321 Vs 16:20:29 Integrated Voltage Measurement... 16:21:01 Voltage Offset Correction: v_off_ini = 0.000000575 V, v_off_fin = -0.000002736 V 16:21:01 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143085008 Vs 16:21:02   Voltage Measurement, V = 0.000000 V 16:21:03 Temperature Measurement, Probe Number = 0, T = 21.501000 C 16:21:03 Temperature Measurement, Probe Number = 1, T = 22.525000 C 16:21:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.50 P2 = 3458_Meas_Junction, Value = 22.52 16:21:03 Integrated Voltage Measurement... 16:21:34 Voltage Offset Correction: v_off_ini = -0.000000777 V, v_off_fin = 0.000001177 V 16:21:34 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143119502 Vs 16:21:34 Integrated Voltage Measurement... 16:22:06 Voltage Offset Correction: v_off_ini = 0.000000723 V, v_off_fin = -0.000001777 V 16:22:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143082807 Vs