SLAC Magnetic Measurements Date: 10-28-2020 Time: 18:16:09 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_012_Cell_37_Upstairs Serial Number: PC33408 Run Number: 5 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement upstairs, cable through switch. Full Set 5 18:16:28 Ambient Measurement Device(s) Being Used, type = None 18:16:28 Magnet Voltage Measurement Device(s) Being Used, type = None 18:16:28 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 18:16:28 XMAG Device(s) Being Used, type = None 18:16:28 Ambient Measurement Device(s) Being Used, type = None 18:16:30   Voltage Measurement, V = 0.000000 V 18:16:31 Temperature Measurement, Probe Number = 0, T = 26.084000 C 18:16:32 Temperature Measurement, Probe Number = 1, T = 27.234000 C 18:16:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.08 P2 = 3458_Meas_Junction, Value = 27.23 18:16:32 Integrated Voltage Measurement... 18:16:57 Voltage Offset Correction: v_off_ini = 0.000003890 V, v_off_fin = 0.000004700 V 18:16:57 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.143121618 Vs 18:16:57 Integrated Voltage Measurement... 18:18:15 Voltage Offset Correction: v_off_ini = 0.000003929 V, v_off_fin = 0.000001257 V 18:18:15 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143088933 Vs 18:18:16   Voltage Measurement, V = 0.000000 V 18:18:17 Temperature Measurement, Probe Number = 0, T = 26.029000 C 18:18:17 Temperature Measurement, Probe Number = 1, T = 27.164000 C 18:18:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.03 P2 = 3458_Meas_Junction, Value = 27.16 18:18:17 Integrated Voltage Measurement... 18:18:52 Voltage Offset Correction: v_off_ini = 0.000003149 V, v_off_fin = 0.000005718 V 18:18:52 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143106715 Vs 18:18:52 Integrated Voltage Measurement... 18:19:27 Voltage Offset Correction: v_off_ini = 0.000004046 V, v_off_fin = 0.000002095 V 18:19:27 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143085102 Vs 18:19:28   Voltage Measurement, V = 0.000000 V 18:19:28 Temperature Measurement, Probe Number = 0, T = 26.028000 C 18:19:29 Temperature Measurement, Probe Number = 1, T = 27.133000 C 18:19:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.03 P2 = 3458_Meas_Junction, Value = 27.13 18:19:29 Integrated Voltage Measurement... 18:20:04 Voltage Offset Correction: v_off_ini = 0.000002891 V, v_off_fin = 0.000005358 V 18:20:04 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143109170 Vs 18:20:04 Integrated Voltage Measurement... 18:20:36 Voltage Offset Correction: v_off_ini = 0.000004083 V, v_off_fin = 0.000001777 V 18:20:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143086256 Vs 18:20:37   Voltage Measurement, V = 0.000000 V 18:20:38 Temperature Measurement, Probe Number = 0, T = 26.004000 C 18:20:38 Temperature Measurement, Probe Number = 1, T = 27.102000 C 18:20:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.00 P2 = 3458_Meas_Junction, Value = 27.10 18:20:38 Integrated Voltage Measurement... 18:21:09 Voltage Offset Correction: v_off_ini = 0.000002422 V, v_off_fin = 0.000005310 V 18:21:09 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143117633 Vs 18:21:09 Integrated Voltage Measurement... 18:21:46 Voltage Offset Correction: v_off_ini = 0.000004138 V, v_off_fin = 0.000001475 V 18:21:46 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143080321 Vs 18:21:47   Voltage Measurement, V = 0.000000 V 18:21:47 Temperature Measurement, Probe Number = 0, T = 26.006000 C 18:21:48 Temperature Measurement, Probe Number = 1, T = 27.076000 C 18:21:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.01 P2 = 3458_Meas_Junction, Value = 27.08 18:21:48 Integrated Voltage Measurement... 18:22:18 Voltage Offset Correction: v_off_ini = 0.000002521 V, v_off_fin = 0.000004253 V 18:22:18 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143113311 Vs 18:22:18 Integrated Voltage Measurement... 18:22:53 Voltage Offset Correction: v_off_ini = 0.000004039 V, v_off_fin = 0.000001554 V 18:22:53 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143080394 Vs 18:22:54   Voltage Measurement, V = 0.000000 V 18:22:54 Temperature Measurement, Probe Number = 0, T = 25.990000 C 18:22:55 Temperature Measurement, Probe Number = 1, T = 27.050000 C 18:22:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.99 P2 = 3458_Meas_Junction, Value = 27.05 18:22:55 Integrated Voltage Measurement... 18:23:34 Voltage Offset Correction: v_off_ini = 0.000002654 V, v_off_fin = 0.000004221 V 18:23:34 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143111363 Vs 18:23:34 Integrated Voltage Measurement... 18:24:07 Voltage Offset Correction: v_off_ini = 0.000003987 V, v_off_fin = 0.000001816 V 18:24:07 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143082003 Vs 18:24:08   Voltage Measurement, V = 0.000000 V 18:24:08 Temperature Measurement, Probe Number = 0, T = 25.988000 C 18:24:09 Temperature Measurement, Probe Number = 1, T = 27.027000 C 18:24:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.99 P2 = 3458_Meas_Junction, Value = 27.03 18:24:09 Integrated Voltage Measurement... 18:24:43 Voltage Offset Correction: v_off_ini = 0.000002564 V, v_off_fin = 0.000005259 V 18:24:43 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143123020 Vs 18:24:43 Integrated Voltage Measurement... 18:25:15 Voltage Offset Correction: v_off_ini = 0.000004204 V, v_off_fin = 0.000002373 V 18:25:15 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143081225 Vs 18:25:16   Voltage Measurement, V = 0.000000 V 18:25:17 Temperature Measurement, Probe Number = 0, T = 25.967000 C 18:25:17 Temperature Measurement, Probe Number = 1, T = 26.999000 C 18:25:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.97 P2 = 3458_Meas_Junction, Value = 27.00 18:25:17 Integrated Voltage Measurement... 18:25:49 Voltage Offset Correction: v_off_ini = 0.000002565 V, v_off_fin = 0.000004948 V 18:25:49 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143113117 Vs 18:25:49 Integrated Voltage Measurement... 18:26:24 Voltage Offset Correction: v_off_ini = 0.000003861 V, v_off_fin = 0.000001104 V 18:26:24 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143070368 Vs 18:26:25   Voltage Measurement, V = 0.000000 V 18:26:26 Temperature Measurement, Probe Number = 0, T = 25.975000 C 18:26:26 Temperature Measurement, Probe Number = 1, T = 26.988000 C 18:26:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.98 P2 = 3458_Meas_Junction, Value = 26.99 18:26:26 Integrated Voltage Measurement... 18:26:57 Voltage Offset Correction: v_off_ini = 0.000002717 V, v_off_fin = 0.000004930 V 18:26:57 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143104021 Vs 18:26:57 Integrated Voltage Measurement... 18:27:28 Voltage Offset Correction: v_off_ini = 0.000004203 V, v_off_fin = 0.000001145 V 18:27:28 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143078503 Vs 18:27:29   Voltage Measurement, V = 0.000000 V 18:27:30 Temperature Measurement, Probe Number = 0, T = 25.961000 C 18:27:30 Temperature Measurement, Probe Number = 1, T = 26.971000 C 18:27:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 25.96 P2 = 3458_Meas_Junction, Value = 26.97 18:27:30 Integrated Voltage Measurement... 18:28:06 Voltage Offset Correction: v_off_ini = 0.000002538 V, v_off_fin = 0.000004923 V 18:28:06 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143124543 Vs 18:28:06 Integrated Voltage Measurement... 18:28:37 Voltage Offset Correction: v_off_ini = 0.000004151 V, v_off_fin = 0.000001497 V 18:28:37 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143081855 Vs