SLAC Magnetic Measurements Date: 01-20-2021 Time: 17:24:18 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_012_Cell_37 Serial Number: PC33408 Run Number: 16 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 16, no beam between 15 & 16 17:24:36 Ambient Measurement Device(s) Being Used, type = None 17:24:36 Magnet Voltage Measurement Device(s) Being Used, type = None 17:24:36 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 17:24:36 XMAG Device(s) Being Used, type = None 17:24:36 Ambient Measurement Device(s) Being Used, type = None 17:24:45   Voltage Measurement, V = 0.000000 V 17:24:46 Temperature Measurement, Probe Number = 0, T = 20.902000 C 17:24:46 Temperature Measurement, Probe Number = 1, T = 21.866000 C 17:24:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.90 P2 = 3458_Meas_Junction, Value = 21.87 17:24:46 Integrated Voltage Measurement... 17:26:13 Voltage Offset Correction: v_off_ini = 0.000000841 V, v_off_fin = 0.000001714 V 17:26:13 Integrated Voltage Measurement Delta Gap = 0.0039995 m VT = 0.143040439 Vs 17:26:13 Integrated Voltage Measurement... 17:26:43 Voltage Offset Correction: v_off_ini = 0.000001161 V, v_off_fin = -0.000001423 V 17:26:43 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143054809 Vs 17:26:44   Voltage Measurement, V = 0.000000 V 17:26:44 Temperature Measurement, Probe Number = 0, T = 20.901000 C 17:26:45 Temperature Measurement, Probe Number = 1, T = 21.917000 C 17:26:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.90 P2 = 3458_Meas_Junction, Value = 21.92 17:26:45 Integrated Voltage Measurement... 17:27:16 Voltage Offset Correction: v_off_ini = -0.000000636 V, v_off_fin = 0.000001623 V 17:27:16 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143080395 Vs 17:27:16 Integrated Voltage Measurement... 17:27:47 Voltage Offset Correction: v_off_ini = 0.000000823 V, v_off_fin = -0.000002212 V 17:27:47 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143046702 Vs 17:27:48   Voltage Measurement, V = 0.000000 V 17:27:48 Temperature Measurement, Probe Number = 0, T = 20.898000 C 17:27:49 Temperature Measurement, Probe Number = 1, T = 21.906000 C 17:27:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.90 P2 = 3458_Meas_Junction, Value = 21.91 17:27:49 Integrated Voltage Measurement... 17:28:20 Voltage Offset Correction: v_off_ini = -0.000000479 V, v_off_fin = 0.000001893 V 17:28:20 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143083842 Vs 17:28:20 Integrated Voltage Measurement... 17:28:51 Voltage Offset Correction: v_off_ini = 0.000000764 V, v_off_fin = -0.000001784 V 17:28:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143051192 Vs 17:28:52   Voltage Measurement, V = 0.000000 V 17:28:52 Temperature Measurement, Probe Number = 0, T = 20.895000 C 17:28:53 Temperature Measurement, Probe Number = 1, T = 21.891000 C 17:28:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.89 P2 = 3458_Meas_Junction, Value = 21.89 17:28:53 Integrated Voltage Measurement... 17:29:26 Voltage Offset Correction: v_off_ini = -0.000000620 V, v_off_fin = 0.000001081 V 17:29:26 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143090007 Vs 17:29:26 Integrated Voltage Measurement... 17:29:56 Voltage Offset Correction: v_off_ini = 0.000000735 V, v_off_fin = -0.000001408 V 17:29:56 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143055538 Vs 17:29:57   Voltage Measurement, V = 0.000000 V 17:29:58 Temperature Measurement, Probe Number = 0, T = 20.899000 C 17:29:59 Temperature Measurement, Probe Number = 1, T = 21.908000 C 17:29:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.90 P2 = 3458_Meas_Junction, Value = 21.91 17:29:59 Integrated Voltage Measurement... 17:30:39 Voltage Offset Correction: v_off_ini = -0.000000388 V, v_off_fin = 0.000002057 V 17:30:39 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143080833 Vs 17:30:39 Integrated Voltage Measurement... 17:31:19 Voltage Offset Correction: v_off_ini = 0.000000529 V, v_off_fin = -0.000002875 V 17:31:19 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143053032 Vs 17:31:20   Voltage Measurement, V = 0.000000 V 17:31:21 Temperature Measurement, Probe Number = 0, T = 20.901000 C 17:31:21 Temperature Measurement, Probe Number = 1, T = 21.914000 C 17:31:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.90 P2 = 3458_Meas_Junction, Value = 21.91 17:31:21 Integrated Voltage Measurement... 17:31:59 Voltage Offset Correction: v_off_ini = -0.000000601 V, v_off_fin = 0.000001142 V 17:31:59 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143089609 Vs 17:31:59 Integrated Voltage Measurement... 17:32:41 Voltage Offset Correction: v_off_ini = 0.000000636 V, v_off_fin = -0.000001701 V 17:32:41 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143065409 Vs 17:32:42   Voltage Measurement, V = 0.000000 V 17:32:43 Temperature Measurement, Probe Number = 0, T = 20.892000 C 17:32:43 Temperature Measurement, Probe Number = 1, T = 21.912000 C 17:32:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.89 P2 = 3458_Meas_Junction, Value = 21.91 17:32:43 Integrated Voltage Measurement... 17:33:34 Voltage Offset Correction: v_off_ini = -0.000000255 V, v_off_fin = 0.000001459 V 17:33:34 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143096010 Vs 17:33:34 Integrated Voltage Measurement... 17:34:08 Voltage Offset Correction: v_off_ini = 0.000000734 V, v_off_fin = -0.000000708 V 17:34:08 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143065318 Vs 17:34:09   Voltage Measurement, V = 0.000000 V 17:34:09 Temperature Measurement, Probe Number = 0, T = 20.890000 C 17:34:10 Temperature Measurement, Probe Number = 1, T = 21.893000 C 17:34:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.89 P2 = 3458_Meas_Junction, Value = 21.89 17:34:10 Integrated Voltage Measurement... 17:34:41 Voltage Offset Correction: v_off_ini = -0.000000777 V, v_off_fin = 0.000001244 V 17:34:41 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143089856 Vs 17:34:41 Integrated Voltage Measurement... 17:35:11 Voltage Offset Correction: v_off_ini = 0.000000728 V, v_off_fin = -0.000002363 V 17:35:12 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143056678 Vs 17:35:13   Voltage Measurement, V = 0.000000 V 17:35:13 Temperature Measurement, Probe Number = 0, T = 20.886000 C 17:35:14 Temperature Measurement, Probe Number = 1, T = 21.879000 C 17:35:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.89 P2 = 3458_Meas_Junction, Value = 21.88 17:35:14 Integrated Voltage Measurement... 17:35:44 Voltage Offset Correction: v_off_ini = -0.000000983 V, v_off_fin = 0.000001522 V 17:35:44 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143094849 Vs 17:35:44 Integrated Voltage Measurement... 17:36:14 Voltage Offset Correction: v_off_ini = 0.000000806 V, v_off_fin = -0.000002716 V 17:36:14 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143054823 Vs 17:36:16   Voltage Measurement, V = 0.000000 V 17:36:16 Temperature Measurement, Probe Number = 0, T = 20.880000 C 17:36:17 Temperature Measurement, Probe Number = 1, T = 21.882000 C 17:36:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.88 P2 = 3458_Meas_Junction, Value = 21.88 17:36:17 Integrated Voltage Measurement... 17:36:47 Voltage Offset Correction: v_off_ini = -0.000000939 V, v_off_fin = 0.000001459 V 17:36:47 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143098479 Vs 17:36:47 Integrated Voltage Measurement... 17:37:20 Voltage Offset Correction: v_off_ini = 0.000000569 V, v_off_fin = -0.000002269 V 17:37:20 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.143060465 Vs