SLAC Magnetic Measurements Date: 12-02-2020 Time: 14:49:49 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_012_Cell_37 Serial Number: PC33408 Run Number: 14 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full set 14 14:50:06 Ambient Measurement Device(s) Being Used, type = None 14:50:06 Magnet Voltage Measurement Device(s) Being Used, type = None 14:50:07 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 14:50:07 XMAG Device(s) Being Used, type = None 14:50:07 Ambient Measurement Device(s) Being Used, type = None 14:50:19   Voltage Measurement, V = 0.000000 V 14:50:19 Temperature Measurement, Probe Number = 0, T = 21.124000 C 14:50:20 Temperature Measurement, Probe Number = 1, T = 22.658000 C 14:50:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.12 P2 = 3458_Meas_Junction, Value = 22.66 14:50:20 Integrated Voltage Measurement... 14:50:47 Voltage Offset Correction: v_off_ini = 0.000000396 V, v_off_fin = 0.000000915 V 14:50:47 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143113909 Vs 14:50:47 Integrated Voltage Measurement... 14:51:18 Voltage Offset Correction: v_off_ini = 0.000001067 V, v_off_fin = -0.000001521 V 14:51:18 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143073462 Vs 14:51:19   Voltage Measurement, V = 0.000000 V 14:51:20 Temperature Measurement, Probe Number = 0, T = 21.121000 C 14:51:20 Temperature Measurement, Probe Number = 1, T = 22.656000 C 14:51:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.12 P2 = 3458_Meas_Junction, Value = 22.66 14:51:20 Integrated Voltage Measurement... 14:51:51 Voltage Offset Correction: v_off_ini = -0.000000323 V, v_off_fin = 0.000002002 V 14:51:51 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143096419 Vs 14:51:51 Integrated Voltage Measurement... 14:52:22 Voltage Offset Correction: v_off_ini = 0.000000844 V, v_off_fin = -0.000001664 V 14:52:22 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143075986 Vs 14:52:23   Voltage Measurement, V = 0.000000 V 14:52:24 Temperature Measurement, Probe Number = 0, T = 21.122000 C 14:52:24 Temperature Measurement, Probe Number = 1, T = 22.680000 C 14:52:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.12 P2 = 3458_Meas_Junction, Value = 22.68 14:52:24 Integrated Voltage Measurement... 14:52:55 Voltage Offset Correction: v_off_ini = -0.000000511 V, v_off_fin = 0.000001304 V 14:52:55 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143100062 Vs 14:52:55 Integrated Voltage Measurement... 14:53:26 Voltage Offset Correction: v_off_ini = 0.000000777 V, v_off_fin = -0.000001740 V 14:53:26 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143082396 Vs 14:53:27   Voltage Measurement, V = 0.000000 V 14:53:28 Temperature Measurement, Probe Number = 0, T = 21.121000 C 14:53:28 Temperature Measurement, Probe Number = 1, T = 22.702000 C 14:53:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.12 P2 = 3458_Meas_Junction, Value = 22.70 14:53:28 Integrated Voltage Measurement... 14:54:00 Voltage Offset Correction: v_off_ini = -0.000000720 V, v_off_fin = 0.000000778 V 14:54:00 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143116517 Vs 14:54:00 Integrated Voltage Measurement... 14:54:31 Voltage Offset Correction: v_off_ini = 0.000000697 V, v_off_fin = -0.000001877 V 14:54:31 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143071082 Vs 14:54:32   Voltage Measurement, V = 0.000000 V 14:54:32 Temperature Measurement, Probe Number = 0, T = 21.125000 C 14:54:33 Temperature Measurement, Probe Number = 1, T = 22.731000 C 14:54:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.12 P2 = 3458_Meas_Junction, Value = 22.73 14:54:33 Integrated Voltage Measurement... 14:55:04 Voltage Offset Correction: v_off_ini = -0.000000913 V, v_off_fin = 0.000001067 V 14:55:04 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143113466 Vs 14:55:04 Integrated Voltage Measurement... 14:55:35 Voltage Offset Correction: v_off_ini = 0.000000891 V, v_off_fin = -0.000000994 V 14:55:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143081158 Vs 14:55:36   Voltage Measurement, V = 0.000000 V 14:55:37 Temperature Measurement, Probe Number = 0, T = 21.135000 C 14:55:37 Temperature Measurement, Probe Number = 1, T = 22.759000 C 14:55:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.14 P2 = 3458_Meas_Junction, Value = 22.76 14:55:37 Integrated Voltage Measurement... 14:56:08 Voltage Offset Correction: v_off_ini = -0.000000926 V, v_off_fin = 0.000002147 V 14:56:08 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143110597 Vs 14:56:08 Integrated Voltage Measurement... 14:56:40 Voltage Offset Correction: v_off_ini = 0.000000647 V, v_off_fin = -0.000002389 V 14:56:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143077254 Vs 14:56:41   Voltage Measurement, V = 0.000000 V 14:56:41 Temperature Measurement, Probe Number = 0, T = 21.131000 C 14:56:42 Temperature Measurement, Probe Number = 1, T = 22.752000 C 14:56:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.13 P2 = 3458_Meas_Junction, Value = 22.75 14:56:42 Integrated Voltage Measurement... 14:57:13 Voltage Offset Correction: v_off_ini = -0.000000893 V, v_off_fin = 0.000000883 V 14:57:13 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143112822 Vs 14:57:13 Integrated Voltage Measurement... 14:57:44 Voltage Offset Correction: v_off_ini = 0.000000964 V, v_off_fin = -0.000001200 V 14:57:44 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143068953 Vs 14:57:45   Voltage Measurement, V = 0.000000 V 14:57:45 Temperature Measurement, Probe Number = 0, T = 21.131000 C 14:57:46 Temperature Measurement, Probe Number = 1, T = 22.771000 C 14:57:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.13 P2 = 3458_Meas_Junction, Value = 22.77 14:57:46 Integrated Voltage Measurement... 14:58:17 Voltage Offset Correction: v_off_ini = -0.000000924 V, v_off_fin = 0.000000770 V 14:58:17 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143108085 Vs 14:58:17 Integrated Voltage Measurement... 14:58:51 Voltage Offset Correction: v_off_ini = 0.000000802 V, v_off_fin = -0.000001926 V 14:58:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143086057 Vs 14:58:52   Voltage Measurement, V = 0.000000 V 14:58:53 Temperature Measurement, Probe Number = 0, T = 21.130000 C 14:58:54 Temperature Measurement, Probe Number = 1, T = 22.777000 C 14:58:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.13 P2 = 3458_Meas_Junction, Value = 22.78 14:58:54 Integrated Voltage Measurement... 14:59:24 Voltage Offset Correction: v_off_ini = -0.000000893 V, v_off_fin = 0.000000668 V 14:59:24 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143121396 Vs 14:59:24 Integrated Voltage Measurement... 14:59:54 Voltage Offset Correction: v_off_ini = 0.000000833 V, v_off_fin = -0.000002969 V 14:59:54 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143071230 Vs 14:59:55   Voltage Measurement, V = 0.000000 V 14:59:55 Temperature Measurement, Probe Number = 0, T = 21.130000 C 14:59:56 Temperature Measurement, Probe Number = 1, T = 22.787000 C 14:59:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.13 P2 = 3458_Meas_Junction, Value = 22.79 14:59:56 Integrated Voltage Measurement... 15:00:35 Voltage Offset Correction: v_off_ini = -0.000000452 V, v_off_fin = 0.000001766 V 15:00:35 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143104651 Vs 15:00:35 Integrated Voltage Measurement... 15:01:21 Voltage Offset Correction: v_off_ini = 0.000000473 V, v_off_fin = -0.000001052 V 15:01:21 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143060113 Vs