SLAC Magnetic Measurements Date: 11-18-2020 Time: 14:32:39 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_012_Cell_37 Serial Number: PC33408 Run Number: 13 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 13 14:32:57 Ambient Measurement Device(s) Being Used, type = None 14:32:57 Magnet Voltage Measurement Device(s) Being Used, type = None 14:32:57 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 14:32:57 XMAG Device(s) Being Used, type = None 14:32:57 Ambient Measurement Device(s) Being Used, type = None 14:33:06   Voltage Measurement, V = 0.000000 V 14:33:07 Temperature Measurement, Probe Number = 0, T = 21.210000 C 14:33:07 Temperature Measurement, Probe Number = 1, T = 21.701000 C 14:33:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.21 P2 = 3458_Meas_Junction, Value = 21.70 14:33:07 Integrated Voltage Measurement... 14:33:33 Voltage Offset Correction: v_off_ini = -0.000000402 V, v_off_fin = 0.000000553 V 14:33:33 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143143804 Vs 14:33:33 Integrated Voltage Measurement... 14:34:04 Voltage Offset Correction: v_off_ini = 0.000000339 V, v_off_fin = -0.000002514 V 14:34:04 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143110078 Vs 14:34:05   Voltage Measurement, V = 0.000000 V 14:34:06 Temperature Measurement, Probe Number = 0, T = 21.148000 C 14:34:07 Temperature Measurement, Probe Number = 1, T = 21.721000 C 14:34:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.15 P2 = 3458_Meas_Junction, Value = 21.72 14:34:07 Integrated Voltage Measurement... 14:34:45 Voltage Offset Correction: v_off_ini = -0.000001085 V, v_off_fin = 0.000000773 V 14:34:45 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143130563 Vs 14:34:45 Integrated Voltage Measurement... 14:35:17 Voltage Offset Correction: v_off_ini = 0.000000129 V, v_off_fin = -0.000001725 V 14:35:17 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143106157 Vs 14:35:18   Voltage Measurement, V = 0.000000 V 14:35:19 Temperature Measurement, Probe Number = 0, T = 21.097000 C 14:35:19 Temperature Measurement, Probe Number = 1, T = 21.721000 C 14:35:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.10 P2 = 3458_Meas_Junction, Value = 21.72 14:35:19 Integrated Voltage Measurement... 14:35:51 Voltage Offset Correction: v_off_ini = -0.000001666 V, v_off_fin = 0.000000431 V 14:35:51 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143141575 Vs 14:35:51 Integrated Voltage Measurement... 14:36:23 Voltage Offset Correction: v_off_ini = 0.000000117 V, v_off_fin = -0.000002034 V 14:36:23 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143113440 Vs 14:36:24   Voltage Measurement, V = 0.000000 V 14:36:25 Temperature Measurement, Probe Number = 0, T = 21.045000 C 14:36:26 Temperature Measurement, Probe Number = 1, T = 21.731000 C 14:36:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.05 P2 = 3458_Meas_Junction, Value = 21.73 14:36:26 Integrated Voltage Measurement... 14:36:56 Voltage Offset Correction: v_off_ini = -0.000001569 V, v_off_fin = 0.000000366 V 14:36:56 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143142356 Vs 14:36:56 Integrated Voltage Measurement... 14:37:29 Voltage Offset Correction: v_off_ini = 0.000000023 V, v_off_fin = -0.000003425 V 14:37:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143112398 Vs 14:37:30   Voltage Measurement, V = 0.000000 V 14:37:30 Temperature Measurement, Probe Number = 0, T = 21.020000 C 14:37:31 Temperature Measurement, Probe Number = 1, T = 21.723000 C 14:37:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.02 P2 = 3458_Meas_Junction, Value = 21.72 14:37:31 Integrated Voltage Measurement... 14:38:03 Voltage Offset Correction: v_off_ini = -0.000001449 V, v_off_fin = 0.000000151 V 14:38:03 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143146011 Vs 14:38:03 Integrated Voltage Measurement... 14:38:35 Voltage Offset Correction: v_off_ini = -0.000000028 V, v_off_fin = -0.000002489 V 14:38:35 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143113320 Vs 14:38:36   Voltage Measurement, V = 0.000000 V 14:38:37 Temperature Measurement, Probe Number = 0, T = 21.006000 C 14:38:38 Temperature Measurement, Probe Number = 1, T = 21.714000 C 14:38:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.01 P2 = 3458_Meas_Junction, Value = 21.71 14:38:38 Integrated Voltage Measurement... 14:39:08 Voltage Offset Correction: v_off_ini = -0.000001710 V, v_off_fin = 0.000000296 V 14:39:08 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143137600 Vs 14:39:08 Integrated Voltage Measurement... 14:39:39 Voltage Offset Correction: v_off_ini = -0.000000123 V, v_off_fin = -0.000003250 V 14:39:39 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143123867 Vs 14:39:40   Voltage Measurement, V = 0.000000 V 14:39:41 Temperature Measurement, Probe Number = 0, T = 20.996000 C 14:39:41 Temperature Measurement, Probe Number = 1, T = 21.703000 C 14:39:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.00 P2 = 3458_Meas_Junction, Value = 21.70 14:39:41 Integrated Voltage Measurement... 14:40:12 Voltage Offset Correction: v_off_ini = -0.000001577 V, v_off_fin = 0.000000645 V 14:40:12 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143150140 Vs 14:40:12 Integrated Voltage Measurement... 14:40:42 Voltage Offset Correction: v_off_ini = -0.000000077 V, v_off_fin = -0.000003203 V 14:40:42 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143113070 Vs 14:40:43   Voltage Measurement, V = 0.000000 V 14:40:44 Temperature Measurement, Probe Number = 0, T = 20.986000 C 14:40:45 Temperature Measurement, Probe Number = 1, T = 21.707000 C 14:40:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.99 P2 = 3458_Meas_Junction, Value = 21.71 14:40:45 Integrated Voltage Measurement... 14:41:15 Voltage Offset Correction: v_off_ini = -0.000001655 V, v_off_fin = 0.000000393 V 14:41:15 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143153926 Vs 14:41:15 Integrated Voltage Measurement... 14:41:59 Voltage Offset Correction: v_off_ini = -0.000000044 V, v_off_fin = -0.000002609 V 14:41:59 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143119775 Vs 14:42:00   Voltage Measurement, V = 0.000000 V 14:42:00 Temperature Measurement, Probe Number = 0, T = 20.974000 C 14:42:01 Temperature Measurement, Probe Number = 1, T = 21.705000 C 14:42:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.97 P2 = 3458_Meas_Junction, Value = 21.70 14:42:01 Integrated Voltage Measurement... 14:42:34 Voltage Offset Correction: v_off_ini = -0.000001100 V, v_off_fin = -0.000000001 V 14:42:34 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143150572 Vs 14:42:34 Integrated Voltage Measurement... 14:43:24 Voltage Offset Correction: v_off_ini = -0.000000170 V, v_off_fin = -0.000002781 V 14:43:24 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143111528 Vs 14:43:25   Voltage Measurement, V = 0.000000 V 14:43:26 Temperature Measurement, Probe Number = 0, T = 20.984000 C 14:43:27 Temperature Measurement, Probe Number = 1, T = 21.718000 C 14:43:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.98 P2 = 3458_Meas_Junction, Value = 21.72 14:43:27 Integrated Voltage Measurement... 14:43:57 Voltage Offset Correction: v_off_ini = -0.000001388 V, v_off_fin = 0.000001590 V 14:43:57 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143141055 Vs 14:43:57 Integrated Voltage Measurement... 14:44:29 Voltage Offset Correction: v_off_ini = 0.000000112 V, v_off_fin = -0.000002565 V 14:44:29 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143109616 Vs