SLAC Magnetic Measurements Date: 10-29-2020 Time: 14:29:08 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_012_Cell_37 Serial Number: PC33408 Run Number: 12 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 12 14:29:25 Ambient Measurement Device(s) Being Used, type = None 14:29:25 Magnet Voltage Measurement Device(s) Being Used, type = None 14:29:26 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 14:29:26 XMAG Device(s) Being Used, type = None 14:29:26 Ambient Measurement Device(s) Being Used, type = None 14:29:30   Voltage Measurement, V = 0.000000 V 14:29:31 Temperature Measurement, Probe Number = 0, T = 21.216000 C 14:29:31 Temperature Measurement, Probe Number = 1, T = 22.083000 C 14:29:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.22 P2 = 3458_Meas_Junction, Value = 22.08 14:29:31 Integrated Voltage Measurement... 14:29:57 Voltage Offset Correction: v_off_ini = 0.000000416 V, v_off_fin = 0.000000495 V 14:29:57 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.143130392 Vs 14:29:57 Integrated Voltage Measurement... 14:30:29 Voltage Offset Correction: v_off_ini = 0.000001007 V, v_off_fin = -0.000002872 V 14:30:29 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143081520 Vs 14:30:30   Voltage Measurement, V = 0.000000 V 14:30:31 Temperature Measurement, Probe Number = 0, T = 21.222000 C 14:30:31 Temperature Measurement, Probe Number = 1, T = 22.090000 C 14:30:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.22 P2 = 3458_Meas_Junction, Value = 22.09 14:30:31 Integrated Voltage Measurement... 14:31:04 Voltage Offset Correction: v_off_ini = -0.000000717 V, v_off_fin = 0.000000876 V 14:31:04 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143101290 Vs 14:31:04 Integrated Voltage Measurement... 14:31:37 Voltage Offset Correction: v_off_ini = 0.000000482 V, v_off_fin = -0.000001907 V 14:31:37 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143087017 Vs 14:31:38   Voltage Measurement, V = 0.000000 V 14:31:39 Temperature Measurement, Probe Number = 0, T = 21.230000 C 14:31:39 Temperature Measurement, Probe Number = 1, T = 22.110000 C 14:31:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.23 P2 = 3458_Meas_Junction, Value = 22.11 14:31:39 Integrated Voltage Measurement... 14:32:11 Voltage Offset Correction: v_off_ini = -0.000000828 V, v_off_fin = 0.000001100 V 14:32:11 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143116322 Vs 14:32:11 Integrated Voltage Measurement... 14:32:41 Voltage Offset Correction: v_off_ini = 0.000000641 V, v_off_fin = -0.000003087 V 14:32:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143076453 Vs 14:32:42   Voltage Measurement, V = 0.000000 V 14:32:43 Temperature Measurement, Probe Number = 0, T = 21.239000 C 14:32:44 Temperature Measurement, Probe Number = 1, T = 22.129000 C 14:32:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.24 P2 = 3458_Meas_Junction, Value = 22.13 14:32:44 Integrated Voltage Measurement... 14:33:14 Voltage Offset Correction: v_off_ini = -0.000001238 V, v_off_fin = 0.000001043 V 14:33:14 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143111872 Vs 14:33:14 Integrated Voltage Measurement... 14:33:45 Voltage Offset Correction: v_off_ini = 0.000000606 V, v_off_fin = -0.000002913 V 14:33:45 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143077210 Vs 14:33:46   Voltage Measurement, V = 0.000000 V 14:33:47 Temperature Measurement, Probe Number = 0, T = 21.240000 C 14:33:47 Temperature Measurement, Probe Number = 1, T = 22.150000 C 14:33:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.24 P2 = 3458_Meas_Junction, Value = 22.15 14:33:47 Integrated Voltage Measurement... 14:34:19 Voltage Offset Correction: v_off_ini = -0.000001003 V, v_off_fin = 0.000000591 V 14:34:19 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143118081 Vs 14:34:19 Integrated Voltage Measurement... 14:34:50 Voltage Offset Correction: v_off_ini = 0.000000779 V, v_off_fin = -0.000001617 V 14:34:50 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143072317 Vs 14:34:51   Voltage Measurement, V = 0.000000 V 14:34:52 Temperature Measurement, Probe Number = 0, T = 21.229000 C 14:34:52 Temperature Measurement, Probe Number = 1, T = 22.176000 C 14:34:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.23 P2 = 3458_Meas_Junction, Value = 22.18 14:34:52 Integrated Voltage Measurement... 14:35:24 Voltage Offset Correction: v_off_ini = -0.000000934 V, v_off_fin = 0.000000804 V 14:35:24 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143102009 Vs 14:35:24 Integrated Voltage Measurement... 14:35:56 Voltage Offset Correction: v_off_ini = 0.000000680 V, v_off_fin = -0.000002297 V 14:35:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143074640 Vs 14:35:57   Voltage Measurement, V = 0.000000 V 14:35:58 Temperature Measurement, Probe Number = 0, T = 21.236000 C 14:35:58 Temperature Measurement, Probe Number = 1, T = 22.173000 C 14:35:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.24 P2 = 3458_Meas_Junction, Value = 22.17 14:35:58 Integrated Voltage Measurement... 14:36:29 Voltage Offset Correction: v_off_ini = -0.000001128 V, v_off_fin = 0.000001375 V 14:36:29 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143115450 Vs 14:36:29 Integrated Voltage Measurement... 14:37:00 Voltage Offset Correction: v_off_ini = 0.000000656 V, v_off_fin = -0.000002168 V 14:37:00 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143071063 Vs 14:37:01   Voltage Measurement, V = 0.000000 V 14:37:02 Temperature Measurement, Probe Number = 0, T = 21.231000 C 14:37:03 Temperature Measurement, Probe Number = 1, T = 22.173000 C 14:37:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.23 P2 = 3458_Meas_Junction, Value = 22.17 14:37:03 Integrated Voltage Measurement... 14:37:34 Voltage Offset Correction: v_off_ini = -0.000001444 V, v_off_fin = 0.000000936 V 14:37:34 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143117755 Vs 14:37:34 Integrated Voltage Measurement... 14:38:05 Voltage Offset Correction: v_off_ini = 0.000000680 V, v_off_fin = -0.000002606 V 14:38:05 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143081192 Vs 14:38:06   Voltage Measurement, V = 0.000000 V 14:38:07 Temperature Measurement, Probe Number = 0, T = 21.241000 C 14:38:07 Temperature Measurement, Probe Number = 1, T = 22.183000 C 14:38:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.24 P2 = 3458_Meas_Junction, Value = 22.18 14:38:07 Integrated Voltage Measurement... 14:38:40 Voltage Offset Correction: v_off_ini = -0.000001080 V, v_off_fin = 0.000001615 V 14:38:40 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143114713 Vs 14:38:40 Integrated Voltage Measurement... 14:39:12 Voltage Offset Correction: v_off_ini = 0.000000532 V, v_off_fin = -0.000001766 V 14:39:12 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143078999 Vs 14:39:13   Voltage Measurement, V = 0.000000 V 14:39:14 Temperature Measurement, Probe Number = 0, T = 21.245000 C 14:39:15 Temperature Measurement, Probe Number = 1, T = 22.212000 C 14:39:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.25 P2 = 3458_Meas_Junction, Value = 22.21 14:39:15 Integrated Voltage Measurement... 14:39:46 Voltage Offset Correction: v_off_ini = -0.000001164 V, v_off_fin = 0.000000479 V 14:39:46 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143124309 Vs 14:39:46 Integrated Voltage Measurement... 14:40:16 Voltage Offset Correction: v_off_ini = 0.000000686 V, v_off_fin = -0.000001947 V 14:40:17 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143079340 Vs