SLAC Magnetic Measurements Date: 01-06-2021 Time: 12:58:17 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_011_Cell_42_Upstairs Serial Number: PC97084 Run Number: 8 Measurement Device: WalkerVs Operator: sda Comment: Coil Integral measurement upstairs, cable through switch. Full Set 8 12:58:35 Ambient Measurement Device(s) Being Used, type = None 12:58:35 Magnet Voltage Measurement Device(s) Being Used, type = None 12:58:36 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 12:58:36 XMAG Device(s) Being Used, type = None 12:58:36 Ambient Measurement Device(s) Being Used, type = None 12:58:49   Voltage Measurement, V = 0.000000 V 12:58:50 Temperature Measurement, Probe Number = 0, T = 27.629000 C 12:58:50 Temperature Measurement, Probe Number = 1, T = 27.180000 C 12:58:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.63 P2 = 3458_Meas_Junction, Value = 27.18 12:58:51 Integrated Voltage Measurement... 12:59:17 Voltage Offset Correction: v_off_ini = 0.000007931 V, v_off_fin = 0.000008738 V 12:59:17 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = 0.142986346 Vs 12:59:17 Integrated Voltage Measurement... 12:59:54 Voltage Offset Correction: v_off_ini = 0.000008207 V, v_off_fin = 0.000006012 V 12:59:54 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143003195 Vs 12:59:55   Voltage Measurement, V = 0.000000 V 12:59:55 Temperature Measurement, Probe Number = 0, T = 27.617000 C 12:59:56 Temperature Measurement, Probe Number = 1, T = 27.173000 C 12:59:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.62 P2 = 3458_Meas_Junction, Value = 27.17 12:59:56 Integrated Voltage Measurement... 13:00:29 Voltage Offset Correction: v_off_ini = 0.000007002 V, v_off_fin = 0.000007207 V 13:00:29 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143040256 Vs 13:00:29 Integrated Voltage Measurement... 13:01:14 Voltage Offset Correction: v_off_ini = 0.000008127 V, v_off_fin = 0.000006600 V 13:01:14 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142987333 Vs 13:01:15   Voltage Measurement, V = 0.000000 V 13:01:16 Temperature Measurement, Probe Number = 0, T = 27.622000 C 13:01:17 Temperature Measurement, Probe Number = 1, T = 27.179000 C 13:01:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.62 P2 = 3458_Meas_Junction, Value = 27.18 13:01:17 Integrated Voltage Measurement... 13:02:03 Voltage Offset Correction: v_off_ini = 0.000007893 V, v_off_fin = 0.000009825 V 13:02:03 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143019904 Vs 13:02:03 Integrated Voltage Measurement... 13:02:38 Voltage Offset Correction: v_off_ini = 0.000008198 V, v_off_fin = 0.000005577 V 13:02:38 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143006193 Vs 13:02:39   Voltage Measurement, V = 0.000000 V 13:02:40 Temperature Measurement, Probe Number = 0, T = 27.622000 C 13:02:40 Temperature Measurement, Probe Number = 1, T = 27.179000 C 13:02:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.62 P2 = 3458_Meas_Junction, Value = 27.18 13:02:40 Integrated Voltage Measurement... 13:03:23 Voltage Offset Correction: v_off_ini = 0.000007361 V, v_off_fin = 0.000008468 V 13:03:23 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143064264 Vs 13:03:23 Integrated Voltage Measurement... 13:04:09 Voltage Offset Correction: v_off_ini = 0.000008008 V, v_off_fin = 0.000005076 V 13:04:09 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143009934 Vs 13:04:10   Voltage Measurement, V = 0.000000 V 13:04:11 Temperature Measurement, Probe Number = 0, T = 27.623000 C 13:04:12 Temperature Measurement, Probe Number = 1, T = 27.185000 C 13:04:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.62 P2 = 3458_Meas_Junction, Value = 27.18 13:04:12 Integrated Voltage Measurement... 13:04:51 Voltage Offset Correction: v_off_ini = 0.000007275 V, v_off_fin = 0.000008191 V 13:04:51 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143065914 Vs 13:04:51 Integrated Voltage Measurement... 13:05:40 Voltage Offset Correction: v_off_ini = 0.000008349 V, v_off_fin = 0.000006023 V 13:05:40 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143001149 Vs 13:05:41   Voltage Measurement, V = 0.000000 V 13:05:41 Temperature Measurement, Probe Number = 0, T = 27.627000 C 13:05:42 Temperature Measurement, Probe Number = 1, T = 27.182000 C 13:05:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.63 P2 = 3458_Meas_Junction, Value = 27.18 13:05:42 Integrated Voltage Measurement... 13:06:25 Voltage Offset Correction: v_off_ini = 0.000007710 V, v_off_fin = 0.000008847 V 13:06:25 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = 0.142996198 Vs 13:06:25 Integrated Voltage Measurement... 13:06:56 Voltage Offset Correction: v_off_ini = 0.000008359 V, v_off_fin = 0.000006299 V 13:06:56 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143005905 Vs 13:06:57   Voltage Measurement, V = 0.000000 V 13:06:57 Temperature Measurement, Probe Number = 0, T = 27.627000 C 13:06:58 Temperature Measurement, Probe Number = 1, T = 27.181000 C 13:06:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.63 P2 = 3458_Meas_Junction, Value = 27.18 13:06:58 Integrated Voltage Measurement... 13:07:40 Voltage Offset Correction: v_off_ini = 0.000007292 V, v_off_fin = 0.000009375 V 13:07:40 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143045233 Vs 13:07:40 Integrated Voltage Measurement... 13:08:17 Voltage Offset Correction: v_off_ini = 0.000008419 V, v_off_fin = 0.000004967 V 13:08:17 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143012573 Vs 13:08:18   Voltage Measurement, V = 0.000000 V 13:08:19 Temperature Measurement, Probe Number = 0, T = 27.630000 C 13:08:19 Temperature Measurement, Probe Number = 1, T = 27.182000 C 13:08:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.63 P2 = 3458_Meas_Junction, Value = 27.18 13:08:19 Integrated Voltage Measurement... 13:08:53 Voltage Offset Correction: v_off_ini = 0.000006918 V, v_off_fin = 0.000009332 V 13:08:53 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143060285 Vs 13:08:53 Integrated Voltage Measurement... 13:09:34 Voltage Offset Correction: v_off_ini = 0.000008326 V, v_off_fin = 0.000005029 V 13:09:34 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143008862 Vs 13:09:35   Voltage Measurement, V = 0.000000 V 13:09:35 Temperature Measurement, Probe Number = 0, T = 27.635000 C 13:09:36 Temperature Measurement, Probe Number = 1, T = 27.183000 C 13:09:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.64 P2 = 3458_Meas_Junction, Value = 27.18 13:09:36 Integrated Voltage Measurement... 13:10:10 Voltage Offset Correction: v_off_ini = 0.000007111 V, v_off_fin = 0.000009147 V 13:10:10 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143048271 Vs 13:10:10 Integrated Voltage Measurement... 13:10:40 Voltage Offset Correction: v_off_ini = 0.000008416 V, v_off_fin = 0.000006322 V 13:10:40 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142996591 Vs 13:10:41   Voltage Measurement, V = 0.000000 V 13:10:42 Temperature Measurement, Probe Number = 0, T = 27.637000 C 13:10:42 Temperature Measurement, Probe Number = 1, T = 27.182000 C 13:10:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.64 P2 = 3458_Meas_Junction, Value = 27.18 13:10:42 Integrated Voltage Measurement... 13:11:20 Voltage Offset Correction: v_off_ini = 0.000007288 V, v_off_fin = 0.000009309 V 13:11:20 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143046152 Vs 13:11:20 Integrated Voltage Measurement... 13:12:06 Voltage Offset Correction: v_off_ini = 0.000008400 V, v_off_fin = 0.000005884 V 13:12:06 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142999338 Vs