SLAC Magnetic Measurements Date: 01-20-2021 Time: 18:38:09 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_011_Cell_42 Serial Number: PC33408 Run Number: 16 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 16, no beam between 15 & 16 18:38:27 Ambient Measurement Device(s) Being Used, type = None 18:38:27 Magnet Voltage Measurement Device(s) Being Used, type = None 18:38:27 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 18:38:27 XMAG Device(s) Being Used, type = None 18:38:27 Ambient Measurement Device(s) Being Used, type = None 18:38:34   Voltage Measurement, V = 0.000000 V 18:38:35 Temperature Measurement, Probe Number = 0, T = 21.236000 C 18:38:36 Temperature Measurement, Probe Number = 1, T = 22.162000 C 18:38:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.24 P2 = 3458_Meas_Junction, Value = 22.16 18:38:36 Integrated Voltage Measurement... 18:39:02 Voltage Offset Correction: v_off_ini = 0.000000764 V, v_off_fin = 0.000000326 V 18:39:02 Integrated Voltage Measurement Delta Gap = 0.0039994 m VT = 0.142936575 Vs 18:39:02 Integrated Voltage Measurement... 18:39:33 Voltage Offset Correction: v_off_ini = 0.000000854 V, v_off_fin = -0.000002042 V 18:39:33 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142950066 Vs 18:39:34   Voltage Measurement, V = 0.000000 V 18:39:35 Temperature Measurement, Probe Number = 0, T = 21.225000 C 18:39:35 Temperature Measurement, Probe Number = 1, T = 22.120000 C 18:39:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.23 P2 = 3458_Meas_Junction, Value = 22.12 18:39:35 Integrated Voltage Measurement... 18:40:07 Voltage Offset Correction: v_off_ini = -0.000000521 V, v_off_fin = 0.000000293 V 18:40:07 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143001231 Vs 18:40:07 Integrated Voltage Measurement... 18:40:38 Voltage Offset Correction: v_off_ini = 0.000000585 V, v_off_fin = -0.000002126 V 18:40:38 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142954526 Vs 18:40:39   Voltage Measurement, V = 0.000000 V 18:40:40 Temperature Measurement, Probe Number = 0, T = 21.234000 C 18:40:40 Temperature Measurement, Probe Number = 1, T = 22.164000 C 18:40:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.23 P2 = 3458_Meas_Junction, Value = 22.16 18:40:40 Integrated Voltage Measurement... 18:41:12 Voltage Offset Correction: v_off_ini = -0.000000651 V, v_off_fin = 0.000000113 V 18:41:12 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143001741 Vs 18:41:12 Integrated Voltage Measurement... 18:41:44 Voltage Offset Correction: v_off_ini = 0.000000504 V, v_off_fin = -0.000002391 V 18:41:44 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142953504 Vs 18:41:45   Voltage Measurement, V = 0.000000 V 18:41:45 Temperature Measurement, Probe Number = 0, T = 21.242000 C 18:41:46 Temperature Measurement, Probe Number = 1, T = 22.167000 C 18:41:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.24 P2 = 3458_Meas_Junction, Value = 22.17 18:41:46 Integrated Voltage Measurement... 18:42:18 Voltage Offset Correction: v_off_ini = -0.000000755 V, v_off_fin = 0.000000486 V 18:42:18 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142999828 Vs 18:42:18 Integrated Voltage Measurement... 18:42:48 Voltage Offset Correction: v_off_ini = 0.000000701 V, v_off_fin = -0.000002332 V 18:42:48 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142948179 Vs 18:42:49   Voltage Measurement, V = 0.000000 V 18:42:50 Temperature Measurement, Probe Number = 0, T = 21.252000 C 18:42:51 Temperature Measurement, Probe Number = 1, T = 22.191000 C 18:42:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.25 P2 = 3458_Meas_Junction, Value = 22.19 18:42:51 Integrated Voltage Measurement... 18:43:22 Voltage Offset Correction: v_off_ini = -0.000000918 V, v_off_fin = 0.000000719 V 18:43:22 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142998785 Vs 18:43:22 Integrated Voltage Measurement... 18:43:54 Voltage Offset Correction: v_off_ini = 0.000000522 V, v_off_fin = -0.000002780 V 18:43:54 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142955390 Vs 18:43:55   Voltage Measurement, V = 0.000000 V 18:43:56 Temperature Measurement, Probe Number = 0, T = 21.244000 C 18:43:56 Temperature Measurement, Probe Number = 1, T = 22.196000 C 18:43:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.24 P2 = 3458_Meas_Junction, Value = 22.20 18:43:56 Integrated Voltage Measurement... 18:44:28 Voltage Offset Correction: v_off_ini = -0.000000589 V, v_off_fin = 0.000000491 V 18:44:28 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142986603 Vs 18:44:28 Integrated Voltage Measurement... 18:45:00 Voltage Offset Correction: v_off_ini = 0.000000779 V, v_off_fin = -0.000001404 V 18:45:00 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142959019 Vs 18:45:01   Voltage Measurement, V = 0.000000 V 18:45:01 Temperature Measurement, Probe Number = 0, T = 21.239000 C 18:45:02 Temperature Measurement, Probe Number = 1, T = 22.165000 C 18:45:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.24 P2 = 3458_Meas_Junction, Value = 22.16 18:45:02 Integrated Voltage Measurement... 18:45:33 Voltage Offset Correction: v_off_ini = -0.000000951 V, v_off_fin = 0.000001185 V 18:45:33 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143005814 Vs 18:45:33 Integrated Voltage Measurement... 18:46:05 Voltage Offset Correction: v_off_ini = 0.000000584 V, v_off_fin = -0.000002403 V 18:46:05 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142952520 Vs 18:46:06   Voltage Measurement, V = 0.000000 V 18:46:06 Temperature Measurement, Probe Number = 0, T = 21.229000 C 18:46:07 Temperature Measurement, Probe Number = 1, T = 22.142000 C 18:46:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.23 P2 = 3458_Meas_Junction, Value = 22.14 18:46:07 Integrated Voltage Measurement... 18:46:39 Voltage Offset Correction: v_off_ini = -0.000000821 V, v_off_fin = 0.000000680 V 18:46:39 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143008301 Vs 18:46:39 Integrated Voltage Measurement... 18:47:10 Voltage Offset Correction: v_off_ini = 0.000000377 V, v_off_fin = -0.000002915 V 18:47:10 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142952874 Vs 18:47:11   Voltage Measurement, V = 0.000000 V 18:47:11 Temperature Measurement, Probe Number = 0, T = 21.230000 C 18:47:12 Temperature Measurement, Probe Number = 1, T = 22.144000 C 18:47:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.23 P2 = 3458_Meas_Junction, Value = 22.14 18:47:12 Integrated Voltage Measurement... 18:47:44 Voltage Offset Correction: v_off_ini = -0.000000738 V, v_off_fin = 0.000000172 V 18:47:44 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142998183 Vs 18:47:44 Integrated Voltage Measurement... 18:48:14 Voltage Offset Correction: v_off_ini = 0.000000559 V, v_off_fin = -0.000002508 V 18:48:14 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142955544 Vs 18:48:15   Voltage Measurement, V = 0.000000 V 18:48:16 Temperature Measurement, Probe Number = 0, T = 21.230000 C 18:48:16 Temperature Measurement, Probe Number = 1, T = 22.164000 C 18:48:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.23 P2 = 3458_Meas_Junction, Value = 22.16 18:48:16 Integrated Voltage Measurement... 18:48:47 Voltage Offset Correction: v_off_ini = -0.000001001 V, v_off_fin = 0.000000257 V 18:48:47 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143001175 Vs 18:48:47 Integrated Voltage Measurement... 18:49:19 Voltage Offset Correction: v_off_ini = 0.000000758 V, v_off_fin = -0.000000748 V 18:49:19 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142960146 Vs