SLAC Magnetic Measurements Date: 01-07-2021 Time: 16:49:21 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_011_Cell_42 Serial Number: PC33408 Run Number: 15 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full set 15 16:49:39 Ambient Measurement Device(s) Being Used, type = None 16:49:39 Magnet Voltage Measurement Device(s) Being Used, type = None 16:49:39 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 16:49:39 XMAG Device(s) Being Used, type = None 16:49:39 Ambient Measurement Device(s) Being Used, type = None 16:49:47   Voltage Measurement, V = 0.000000 V 16:49:47 Temperature Measurement, Probe Number = 0, T = 21.200000 C 16:49:48 Temperature Measurement, Probe Number = 1, T = 22.219000 C 16:49:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.20 P2 = 3458_Meas_Junction, Value = 22.22 16:49:48 Integrated Voltage Measurement... 16:50:14 Voltage Offset Correction: v_off_ini = 0.000000396 V, v_off_fin = 0.000001268 V 16:50:14 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.143065128 Vs 16:50:14 Integrated Voltage Measurement... 16:50:45 Voltage Offset Correction: v_off_ini = 0.000000583 V, v_off_fin = -0.000002400 V 16:50:45 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143007715 Vs 16:50:46   Voltage Measurement, V = 0.000000 V 16:50:47 Temperature Measurement, Probe Number = 0, T = 21.183000 C 16:50:47 Temperature Measurement, Probe Number = 1, T = 22.217000 C 16:50:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.18 P2 = 3458_Meas_Junction, Value = 22.22 16:50:47 Integrated Voltage Measurement... 16:51:17 Voltage Offset Correction: v_off_ini = -0.000000868 V, v_off_fin = 0.000001139 V 16:51:17 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143048990 Vs 16:51:17 Integrated Voltage Measurement... 16:51:48 Voltage Offset Correction: v_off_ini = 0.000000751 V, v_off_fin = -0.000002246 V 16:51:48 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143005986 Vs 16:51:49   Voltage Measurement, V = 0.000000 V 16:51:50 Temperature Measurement, Probe Number = 0, T = 21.189000 C 16:51:50 Temperature Measurement, Probe Number = 1, T = 22.214000 C 16:51:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.19 P2 = 3458_Meas_Junction, Value = 22.21 16:51:50 Integrated Voltage Measurement... 16:52:19 Voltage Offset Correction: v_off_ini = -0.000000838 V, v_off_fin = 0.000000663 V 16:52:19 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143052740 Vs 16:52:19 Integrated Voltage Measurement... 16:52:57 Voltage Offset Correction: v_off_ini = 0.000000408 V, v_off_fin = -0.000002601 V 16:52:57 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143001878 Vs 16:52:58   Voltage Measurement, V = 0.000000 V 16:52:59 Temperature Measurement, Probe Number = 0, T = 21.183000 C 16:52:59 Temperature Measurement, Probe Number = 1, T = 22.219000 C 16:52:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.18 P2 = 3458_Meas_Junction, Value = 22.22 16:52:59 Integrated Voltage Measurement... 16:53:29 Voltage Offset Correction: v_off_ini = -0.000000833 V, v_off_fin = 0.000000504 V 16:53:29 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143049196 Vs 16:53:29 Integrated Voltage Measurement... 16:54:01 Voltage Offset Correction: v_off_ini = 0.000000504 V, v_off_fin = -0.000002668 V 16:54:01 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143015225 Vs 16:54:02   Voltage Measurement, V = 0.000000 V 16:54:03 Temperature Measurement, Probe Number = 0, T = 21.180000 C 16:54:03 Temperature Measurement, Probe Number = 1, T = 22.217000 C 16:54:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.18 P2 = 3458_Meas_Junction, Value = 22.22 16:54:04 Integrated Voltage Measurement... 16:54:35 Voltage Offset Correction: v_off_ini = -0.000001166 V, v_off_fin = 0.000000446 V 16:54:35 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143062750 Vs 16:54:35 Integrated Voltage Measurement... 16:55:05 Voltage Offset Correction: v_off_ini = 0.000000494 V, v_off_fin = -0.000002516 V 16:55:05 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143008573 Vs 16:55:06   Voltage Measurement, V = 0.000000 V 16:55:07 Temperature Measurement, Probe Number = 0, T = 21.174000 C 16:55:08 Temperature Measurement, Probe Number = 1, T = 22.221000 C 16:55:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.17 P2 = 3458_Meas_Junction, Value = 22.22 16:55:08 Integrated Voltage Measurement... 16:55:38 Voltage Offset Correction: v_off_ini = -0.000001116 V, v_off_fin = 0.000000655 V 16:55:38 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143067079 Vs 16:55:38 Integrated Voltage Measurement... 16:56:09 Voltage Offset Correction: v_off_ini = 0.000000574 V, v_off_fin = -0.000001062 V 16:56:09 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143006231 Vs 16:56:10   Voltage Measurement, V = 0.000000 V 16:56:11 Temperature Measurement, Probe Number = 0, T = 21.181000 C 16:56:11 Temperature Measurement, Probe Number = 1, T = 22.198000 C 16:56:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.18 P2 = 3458_Meas_Junction, Value = 22.20 16:56:11 Integrated Voltage Measurement... 16:56:43 Voltage Offset Correction: v_off_ini = -0.000000997 V, v_off_fin = 0.000000652 V 16:56:43 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143052520 Vs 16:56:43 Integrated Voltage Measurement... 16:57:13 Voltage Offset Correction: v_off_ini = 0.000000493 V, v_off_fin = -0.000003405 V 16:57:13 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143006473 Vs 16:57:14   Voltage Measurement, V = 0.000000 V 16:57:15 Temperature Measurement, Probe Number = 0, T = 21.185000 C 16:57:15 Temperature Measurement, Probe Number = 1, T = 22.210000 C 16:57:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.18 P2 = 3458_Meas_Junction, Value = 22.21 16:57:15 Integrated Voltage Measurement... 16:57:46 Voltage Offset Correction: v_off_ini = -0.000001043 V, v_off_fin = 0.000000012 V 16:57:46 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143054913 Vs 16:57:46 Integrated Voltage Measurement... 16:58:16 Voltage Offset Correction: v_off_ini = 0.000000527 V, v_off_fin = -0.000002152 V 16:58:16 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143017811 Vs 16:58:17   Voltage Measurement, V = 0.000000 V 16:58:17 Temperature Measurement, Probe Number = 0, T = 21.176000 C 16:58:18 Temperature Measurement, Probe Number = 1, T = 22.212000 C 16:58:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.18 P2 = 3458_Meas_Junction, Value = 22.21 16:58:18 Integrated Voltage Measurement... 16:58:50 Voltage Offset Correction: v_off_ini = -0.000001007 V, v_off_fin = 0.000000268 V 16:58:50 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143062231 Vs 16:58:50 Integrated Voltage Measurement... 16:59:19 Voltage Offset Correction: v_off_ini = 0.000000478 V, v_off_fin = -0.000002684 V 16:59:20 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143005571 Vs 16:59:21   Voltage Measurement, V = 0.000000 V 16:59:21 Temperature Measurement, Probe Number = 0, T = 21.170000 C 16:59:22 Temperature Measurement, Probe Number = 1, T = 22.226000 C 16:59:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.17 P2 = 3458_Meas_Junction, Value = 22.23 16:59:22 Integrated Voltage Measurement... 16:59:52 Voltage Offset Correction: v_off_ini = -0.000000981 V, v_off_fin = 0.000000261 V 16:59:52 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143056955 Vs 16:59:52 Integrated Voltage Measurement... 17:00:23 Voltage Offset Correction: v_off_ini = 0.000000388 V, v_off_fin = -0.000003123 V 17:00:23 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143008557 Vs