SLAC Magnetic Measurements Date: 11-18-2020 Time: 15:48:35 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_011_Cell_42 Serial Number: PC33408 Run Number: 13 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 13 15:48:53 Ambient Measurement Device(s) Being Used, type = None 15:48:53 Magnet Voltage Measurement Device(s) Being Used, type = None 15:49:02 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:49:02 XMAG Device(s) Being Used, type = None 15:49:02 Ambient Measurement Device(s) Being Used, type = None 15:49:05   Voltage Measurement, V = 0.000000 V 15:49:06 Temperature Measurement, Probe Number = 0, T = 21.477000 C 15:49:06 Temperature Measurement, Probe Number = 1, T = 21.970000 C 15:49:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.48 P2 = 3458_Meas_Junction, Value = 21.97 15:49:07 Integrated Voltage Measurement... 15:49:32 Voltage Offset Correction: v_off_ini = -0.000000458 V, v_off_fin = 0.000000896 V 15:49:32 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143113980 Vs 15:49:32 Integrated Voltage Measurement... 15:50:11 Voltage Offset Correction: v_off_ini = 0.000000167 V, v_off_fin = -0.000002223 V 15:50:11 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143078442 Vs 15:50:12   Voltage Measurement, V = 0.000000 V 15:50:13 Temperature Measurement, Probe Number = 0, T = 21.484000 C 15:50:13 Temperature Measurement, Probe Number = 1, T = 21.986000 C 15:50:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.48 P2 = 3458_Meas_Junction, Value = 21.99 15:50:13 Integrated Voltage Measurement... 15:50:44 Voltage Offset Correction: v_off_ini = -0.000001318 V, v_off_fin = 0.000001853 V 15:50:44 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143102215 Vs 15:50:44 Integrated Voltage Measurement... 15:51:17 Voltage Offset Correction: v_off_ini = -0.000000040 V, v_off_fin = -0.000003510 V 15:51:17 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143078970 Vs 15:51:18   Voltage Measurement, V = 0.000000 V 15:51:19 Temperature Measurement, Probe Number = 0, T = 21.480000 C 15:51:20 Temperature Measurement, Probe Number = 1, T = 21.991000 C 15:51:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.48 P2 = 3458_Meas_Junction, Value = 21.99 15:51:20 Integrated Voltage Measurement... 15:51:50 Voltage Offset Correction: v_off_ini = -0.000001619 V, v_off_fin = 0.000000615 V 15:51:50 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143102593 Vs 15:51:50 Integrated Voltage Measurement... 15:52:24 Voltage Offset Correction: v_off_ini = 0.000000240 V, v_off_fin = -0.000002402 V 15:52:24 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143071506 Vs 15:52:25   Voltage Measurement, V = 0.000000 V 15:52:25 Temperature Measurement, Probe Number = 0, T = 21.470000 C 15:52:26 Temperature Measurement, Probe Number = 1, T = 21.986000 C 15:52:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.47 P2 = 3458_Meas_Junction, Value = 21.99 15:52:26 Integrated Voltage Measurement... 15:52:59 Voltage Offset Correction: v_off_ini = -0.000001161 V, v_off_fin = 0.000001285 V 15:52:59 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143083961 Vs 15:52:59 Integrated Voltage Measurement... 15:53:31 Voltage Offset Correction: v_off_ini = 0.000000136 V, v_off_fin = -0.000003000 V 15:53:31 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143074401 Vs 15:53:32   Voltage Measurement, V = 0.000000 V 15:53:32 Temperature Measurement, Probe Number = 0, T = 21.458000 C 15:53:33 Temperature Measurement, Probe Number = 1, T = 22.002000 C 15:53:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.46 P2 = 3458_Meas_Junction, Value = 22.00 15:53:33 Integrated Voltage Measurement... 15:54:05 Voltage Offset Correction: v_off_ini = -0.000001441 V, v_off_fin = 0.000000161 V 15:54:05 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143101416 Vs 15:54:05 Integrated Voltage Measurement... 15:54:36 Voltage Offset Correction: v_off_ini = 0.000000372 V, v_off_fin = -0.000002453 V 15:54:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143088892 Vs 15:54:37   Voltage Measurement, V = 0.000000 V 15:54:37 Temperature Measurement, Probe Number = 0, T = 21.452000 C 15:54:38 Temperature Measurement, Probe Number = 1, T = 22.003000 C 15:54:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.45 P2 = 3458_Meas_Junction, Value = 22.00 15:54:38 Integrated Voltage Measurement... 15:55:19 Voltage Offset Correction: v_off_ini = -0.000001159 V, v_off_fin = 0.000000888 V 15:55:19 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143116025 Vs 15:55:19 Integrated Voltage Measurement... 15:56:10 Voltage Offset Correction: v_off_ini = -0.000000046 V, v_off_fin = -0.000003394 V 15:56:10 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.143076842 Vs 15:56:11   Voltage Measurement, V = 0.000000 V 15:56:11 Temperature Measurement, Probe Number = 0, T = 21.449000 C 15:56:12 Temperature Measurement, Probe Number = 1, T = 22.007000 C 15:56:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.45 P2 = 3458_Meas_Junction, Value = 22.01 15:56:12 Integrated Voltage Measurement... 15:56:42 Voltage Offset Correction: v_off_ini = -0.000001715 V, v_off_fin = 0.000000761 V 15:56:42 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143109183 Vs 15:56:42 Integrated Voltage Measurement... 15:57:15 Voltage Offset Correction: v_off_ini = 0.000000126 V, v_off_fin = -0.000003420 V 15:57:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143079533 Vs 15:57:16   Voltage Measurement, V = 0.000000 V 15:57:16 Temperature Measurement, Probe Number = 0, T = 21.456000 C 15:57:17 Temperature Measurement, Probe Number = 1, T = 22.010000 C 15:57:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.46 P2 = 3458_Meas_Junction, Value = 22.01 15:57:17 Integrated Voltage Measurement... 15:57:53 Voltage Offset Correction: v_off_ini = -0.000001335 V, v_off_fin = 0.000000404 V 15:57:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143115453 Vs 15:57:53 Integrated Voltage Measurement... 15:58:26 Voltage Offset Correction: v_off_ini = 0.000000080 V, v_off_fin = -0.000002868 V 15:58:26 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143074945 Vs 15:58:27   Voltage Measurement, V = 0.000000 V 15:58:28 Temperature Measurement, Probe Number = 0, T = 21.463000 C 15:58:28 Temperature Measurement, Probe Number = 1, T = 22.026000 C 15:58:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.46 P2 = 3458_Meas_Junction, Value = 22.03 15:58:28 Integrated Voltage Measurement... 15:59:02 Voltage Offset Correction: v_off_ini = -0.000001653 V, v_off_fin = 0.000000603 V 15:59:02 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143108180 Vs 15:59:02 Integrated Voltage Measurement... 15:59:32 Voltage Offset Correction: v_off_ini = 0.000000288 V, v_off_fin = -0.000003326 V 15:59:32 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143074622 Vs 15:59:33   Voltage Measurement, V = 0.000000 V 15:59:34 Temperature Measurement, Probe Number = 0, T = 21.472000 C 15:59:34 Temperature Measurement, Probe Number = 1, T = 22.041000 C 15:59:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.47 P2 = 3458_Meas_Junction, Value = 22.04 15:59:34 Integrated Voltage Measurement... 16:00:06 Voltage Offset Correction: v_off_ini = -0.000001528 V, v_off_fin = 0.000000377 V 16:00:06 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143108791 Vs 16:00:06 Integrated Voltage Measurement... 16:00:37 Voltage Offset Correction: v_off_ini = 0.000000210 V, v_off_fin = -0.000002518 V 16:00:37 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143081248 Vs