SLAC Magnetic Measurements Date: 10-21-2020 Time: 14:15:20 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_011_Cell_42 Serial Number: PC33408 Run Number: 11 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 11 14:15:38 Ambient Measurement Device(s) Being Used, type = None 14:15:38 Magnet Voltage Measurement Device(s) Being Used, type = None 14:15:45 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 14:15:45 XMAG Device(s) Being Used, type = None 14:15:45 Ambient Measurement Device(s) Being Used, type = None 14:15:47   Voltage Measurement, V = 0.000000 V 14:15:48 Temperature Measurement, Probe Number = 0, T = 21.539000 C 14:15:49 Temperature Measurement, Probe Number = 1, T = 20.383000 C 14:15:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.54 P2 = 3458_Meas_Junction, Value = 20.38 14:15:49 Integrated Voltage Measurement... 14:16:17 Voltage Offset Correction: v_off_ini = -0.000000567 V, v_off_fin = 0.000000759 V 14:16:17 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143037580 Vs 14:16:17 Integrated Voltage Measurement... 14:16:50 Voltage Offset Correction: v_off_ini = 0.000000443 V, v_off_fin = -0.000002474 V 14:16:50 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143028016 Vs 14:16:51   Voltage Measurement, V = 0.000000 V 14:16:52 Temperature Measurement, Probe Number = 0, T = 21.527000 C 14:16:53 Temperature Measurement, Probe Number = 1, T = 20.367000 C 14:16:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.53 P2 = 3458_Meas_Junction, Value = 20.37 14:16:53 Integrated Voltage Measurement... 14:17:24 Voltage Offset Correction: v_off_ini = -0.000000984 V, v_off_fin = 0.000001378 V 14:17:24 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143031097 Vs 14:17:24 Integrated Voltage Measurement... 14:17:58 Voltage Offset Correction: v_off_ini = 0.000000282 V, v_off_fin = -0.000002101 V 14:17:58 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.143025022 Vs 14:17:59   Voltage Measurement, V = 0.000000 V 14:18:00 Temperature Measurement, Probe Number = 0, T = 21.536000 C 14:18:01 Temperature Measurement, Probe Number = 1, T = 20.376000 C 14:18:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.54 P2 = 3458_Meas_Junction, Value = 20.38 14:18:01 Integrated Voltage Measurement... 14:18:32 Voltage Offset Correction: v_off_ini = -0.000001098 V, v_off_fin = 0.000000513 V 14:18:32 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143025199 Vs 14:18:32 Integrated Voltage Measurement... 14:19:06 Voltage Offset Correction: v_off_ini = 0.000000282 V, v_off_fin = -0.000003107 V 14:19:06 Integrated Voltage Measurement Delta Gap = -0.0040013 m VT = -0.143033705 Vs 14:19:07   Voltage Measurement, V = 0.000000 V 14:19:08 Temperature Measurement, Probe Number = 0, T = 21.564000 C 14:19:08 Temperature Measurement, Probe Number = 1, T = 20.405000 C 14:19:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.56 P2 = 3458_Meas_Junction, Value = 20.41 14:19:09 Integrated Voltage Measurement... 14:19:43 Voltage Offset Correction: v_off_ini = -0.000001010 V, v_off_fin = 0.000001970 V 14:19:43 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143030281 Vs 14:19:43 Integrated Voltage Measurement... 14:20:15 Voltage Offset Correction: v_off_ini = 0.000000358 V, v_off_fin = -0.000002192 V 14:20:15 Integrated Voltage Measurement Delta Gap = -0.0040013 m VT = -0.143030808 Vs 14:20:16   Voltage Measurement, V = 0.000000 V 14:20:17 Temperature Measurement, Probe Number = 0, T = 21.594000 C 14:20:17 Temperature Measurement, Probe Number = 1, T = 20.399000 C 14:20:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.59 P2 = 3458_Meas_Junction, Value = 20.40 14:20:17 Integrated Voltage Measurement... 14:20:49 Voltage Offset Correction: v_off_ini = -0.000001202 V, v_off_fin = 0.000000396 V 14:20:49 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143033224 Vs 14:20:49 Integrated Voltage Measurement... 14:21:21 Voltage Offset Correction: v_off_ini = 0.000000206 V, v_off_fin = -0.000002618 V 14:21:21 Integrated Voltage Measurement Delta Gap = -0.0040013 m VT = -0.143034308 Vs 14:21:22   Voltage Measurement, V = 0.000000 V 14:21:23 Temperature Measurement, Probe Number = 0, T = 21.607000 C 14:21:24 Temperature Measurement, Probe Number = 1, T = 20.394000 C 14:21:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.61 P2 = 3458_Meas_Junction, Value = 20.39 14:21:24 Integrated Voltage Measurement... 14:21:56 Voltage Offset Correction: v_off_ini = -0.000001180 V, v_off_fin = 0.000002413 V 14:21:56 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143026732 Vs 14:21:56 Integrated Voltage Measurement... 14:22:36 Voltage Offset Correction: v_off_ini = 0.000000023 V, v_off_fin = -0.000002544 V 14:22:36 Integrated Voltage Measurement Delta Gap = -0.0040013 m VT = -0.143022859 Vs 14:22:37   Voltage Measurement, V = 0.000000 V 14:22:38 Temperature Measurement, Probe Number = 0, T = 21.612000 C 14:22:39 Temperature Measurement, Probe Number = 1, T = 20.390000 C 14:22:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.61 P2 = 3458_Meas_Junction, Value = 20.39 14:22:39 Integrated Voltage Measurement... 14:23:11 Voltage Offset Correction: v_off_ini = -0.000001144 V, v_off_fin = 0.000001795 V 14:23:11 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143030482 Vs 14:23:11 Integrated Voltage Measurement... 14:23:46 Voltage Offset Correction: v_off_ini = 0.000000123 V, v_off_fin = -0.000002515 V 14:23:46 Integrated Voltage Measurement Delta Gap = -0.0040014 m VT = -0.143035581 Vs 14:23:47   Voltage Measurement, V = 0.000000 V 14:23:47 Temperature Measurement, Probe Number = 0, T = 21.641000 C 14:23:48 Temperature Measurement, Probe Number = 1, T = 20.386000 C 14:23:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.64 P2 = 3458_Meas_Junction, Value = 20.39 14:23:48 Integrated Voltage Measurement... 14:24:20 Voltage Offset Correction: v_off_ini = -0.000000978 V, v_off_fin = 0.000000704 V 14:24:20 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143030547 Vs 14:24:20 Integrated Voltage Measurement... 14:24:53 Voltage Offset Correction: v_off_ini = 0.000000443 V, v_off_fin = -0.000002367 V 14:24:53 Integrated Voltage Measurement Delta Gap = -0.0040015 m VT = -0.143036723 Vs 14:24:54   Voltage Measurement, V = 0.000000 V 14:24:54 Temperature Measurement, Probe Number = 0, T = 21.647000 C 14:24:55 Temperature Measurement, Probe Number = 1, T = 20.387000 C 14:24:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.65 P2 = 3458_Meas_Junction, Value = 20.39 14:24:55 Integrated Voltage Measurement... 14:25:26 Voltage Offset Correction: v_off_ini = -0.000001197 V, v_off_fin = 0.000002287 V 14:25:26 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143031738 Vs 14:25:26 Integrated Voltage Measurement... 14:25:58 Voltage Offset Correction: v_off_ini = 0.000000301 V, v_off_fin = -0.000002260 V 14:25:58 Integrated Voltage Measurement Delta Gap = -0.0040014 m VT = -0.143030788 Vs 14:25:59   Voltage Measurement, V = 0.000000 V 14:25:59 Temperature Measurement, Probe Number = 0, T = 21.646000 C 14:26:00 Temperature Measurement, Probe Number = 1, T = 20.388000 C 14:26:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.65 P2 = 3458_Meas_Junction, Value = 20.39 14:26:00 Integrated Voltage Measurement... 14:26:33 Voltage Offset Correction: v_off_ini = -0.000000927 V, v_off_fin = 0.000001241 V 14:26:33 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143020799 Vs 14:26:33 Integrated Voltage Measurement... 14:27:06 Voltage Offset Correction: v_off_ini = 0.000000279 V, v_off_fin = -0.000002854 V 14:27:06 Integrated Voltage Measurement Delta Gap = -0.0040013 m VT = -0.143024667 Vs