SLAC Magnetic Measurements Date: 01-21-2021 Time: 09:52:49 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_010_Cell_32_Upstairs Serial Number: PC33408 Run Number: 9 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement upstairs, cable through switch Full Set 9 09:53:07 Ambient Measurement Device(s) Being Used, type = None 09:53:07 Magnet Voltage Measurement Device(s) Being Used, type = None 09:53:08 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 09:53:08 XMAG Device(s) Being Used, type = None 09:53:08 Ambient Measurement Device(s) Being Used, type = None 09:53:33   Voltage Measurement, V = 0.000000 V 09:53:33 Temperature Measurement, Probe Number = 0, T = 23.592000 C 09:53:34 Temperature Measurement, Probe Number = 1, T = 24.306000 C 09:53:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.59 P2 = 3458_Meas_Junction, Value = 24.31 09:53:34 Integrated Voltage Measurement... 09:54:00 Voltage Offset Correction: v_off_ini = 0.000005310 V, v_off_fin = 0.000005580 V 09:54:00 Integrated Voltage Measurement Delta Gap = 0.0039996 m VT = 0.143178649 Vs 09:54:00 Integrated Voltage Measurement... 09:54:31 Voltage Offset Correction: v_off_ini = 0.000005336 V, v_off_fin = 0.000003852 V 09:54:31 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143226190 Vs 09:54:32   Voltage Measurement, V = 0.000000 V 09:54:32 Temperature Measurement, Probe Number = 0, T = 23.588000 C 09:54:33 Temperature Measurement, Probe Number = 1, T = 24.297000 C 09:54:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.59 P2 = 3458_Meas_Junction, Value = 24.30 09:54:33 Integrated Voltage Measurement... 09:55:05 Voltage Offset Correction: v_off_ini = 0.000004391 V, v_off_fin = 0.000005679 V 09:55:05 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143244275 Vs 09:55:05 Integrated Voltage Measurement... 09:55:39 Voltage Offset Correction: v_off_ini = 0.000005311 V, v_off_fin = 0.000003750 V 09:55:39 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143225994 Vs 09:55:40   Voltage Measurement, V = 0.000000 V 09:55:40 Temperature Measurement, Probe Number = 0, T = 23.579000 C 09:55:41 Temperature Measurement, Probe Number = 1, T = 24.296000 C 09:55:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.58 P2 = 3458_Meas_Junction, Value = 24.30 09:55:41 Integrated Voltage Measurement... 09:56:13 Voltage Offset Correction: v_off_ini = 0.000004395 V, v_off_fin = 0.000006219 V 09:56:13 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143235287 Vs 09:56:13 Integrated Voltage Measurement... 09:56:45 Voltage Offset Correction: v_off_ini = 0.000005359 V, v_off_fin = 0.000001912 V 09:56:45 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143215634 Vs 09:56:46   Voltage Measurement, V = 0.000000 V 09:56:47 Temperature Measurement, Probe Number = 0, T = 23.566000 C 09:56:48 Temperature Measurement, Probe Number = 1, T = 24.282000 C 09:56:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.57 P2 = 3458_Meas_Junction, Value = 24.28 09:56:48 Integrated Voltage Measurement... 09:57:18 Voltage Offset Correction: v_off_ini = 0.000004075 V, v_off_fin = 0.000005500 V 09:57:18 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143238015 Vs 09:57:18 Integrated Voltage Measurement... 09:57:49 Voltage Offset Correction: v_off_ini = 0.000005440 V, v_off_fin = 0.000003393 V 09:57:49 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143218403 Vs 09:57:50   Voltage Measurement, V = 0.000000 V 09:57:50 Temperature Measurement, Probe Number = 0, T = 23.564000 C 09:57:51 Temperature Measurement, Probe Number = 1, T = 24.276000 C 09:57:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.56 P2 = 3458_Meas_Junction, Value = 24.28 09:57:51 Integrated Voltage Measurement... 09:58:28 Voltage Offset Correction: v_off_ini = 0.000004291 V, v_off_fin = 0.000005161 V 09:58:28 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143238153 Vs 09:58:28 Integrated Voltage Measurement... 09:59:00 Voltage Offset Correction: v_off_ini = 0.000005374 V, v_off_fin = 0.000003407 V 09:59:00 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143225760 Vs 09:59:01   Voltage Measurement, V = 0.000000 V 09:59:02 Temperature Measurement, Probe Number = 0, T = 23.543000 C 09:59:02 Temperature Measurement, Probe Number = 1, T = 24.251000 C 09:59:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.54 P2 = 3458_Meas_Junction, Value = 24.25 09:59:02 Integrated Voltage Measurement... 09:59:39 Voltage Offset Correction: v_off_ini = 0.000004157 V, v_off_fin = 0.000005973 V 09:59:39 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143236318 Vs 09:59:39 Integrated Voltage Measurement... 10:00:19 Voltage Offset Correction: v_off_ini = 0.000005044 V, v_off_fin = 0.000002905 V 10:00:19 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143220840 Vs 10:00:20   Voltage Measurement, V = 0.000000 V 10:00:21 Temperature Measurement, Probe Number = 0, T = 23.532000 C 10:00:21 Temperature Measurement, Probe Number = 1, T = 24.228000 C 10:00:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.53 P2 = 3458_Meas_Junction, Value = 24.23 10:00:21 Integrated Voltage Measurement... 10:00:52 Voltage Offset Correction: v_off_ini = 0.000004266 V, v_off_fin = 0.000005046 V 10:00:52 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143232065 Vs 10:00:52 Integrated Voltage Measurement... 10:01:57 Voltage Offset Correction: v_off_ini = 0.000005229 V, v_off_fin = 0.000003240 V 10:01:57 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143215201 Vs 10:01:58   Voltage Measurement, V = 0.000000 V 10:01:58 Temperature Measurement, Probe Number = 0, T = 23.494000 C 10:01:59 Temperature Measurement, Probe Number = 1, T = 24.208000 C 10:01:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.49 P2 = 3458_Meas_Junction, Value = 24.21 10:01:59 Integrated Voltage Measurement... 10:02:40 Voltage Offset Correction: v_off_ini = 0.000004390 V, v_off_fin = 0.000005603 V 10:02:40 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143239237 Vs 10:02:40 Integrated Voltage Measurement... 10:03:15 Voltage Offset Correction: v_off_ini = 0.000004836 V, v_off_fin = 0.000003399 V 10:03:15 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143208344 Vs 10:03:16   Voltage Measurement, V = 0.000000 V 10:03:17 Temperature Measurement, Probe Number = 0, T = 23.469000 C 10:03:17 Temperature Measurement, Probe Number = 1, T = 24.186000 C 10:03:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.47 P2 = 3458_Meas_Junction, Value = 24.19 10:03:17 Integrated Voltage Measurement... 10:03:48 Voltage Offset Correction: v_off_ini = 0.000003966 V, v_off_fin = 0.000005614 V 10:03:48 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143227020 Vs 10:03:48 Integrated Voltage Measurement... 10:04:22 Voltage Offset Correction: v_off_ini = 0.000004891 V, v_off_fin = 0.000003120 V 10:04:22 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143206796 Vs 10:04:23   Voltage Measurement, V = 0.000000 V 10:04:23 Temperature Measurement, Probe Number = 0, T = 23.453000 C 10:04:24 Temperature Measurement, Probe Number = 1, T = 24.180000 C 10:04:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.45 P2 = 3458_Meas_Junction, Value = 24.18 10:04:24 Integrated Voltage Measurement... 10:04:54 Voltage Offset Correction: v_off_ini = 0.000004353 V, v_off_fin = 0.000005393 V 10:04:54 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143224581 Vs 10:04:54 Integrated Voltage Measurement... 10:05:27 Voltage Offset Correction: v_off_ini = 0.000004745 V, v_off_fin = 0.000003443 V 10:05:27 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143214223 Vs