SLAC Magnetic Measurements Date: 11-18-2020 Time: 13:28:18 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_010_Cell_32 Serial Number: PC33408 Run Number: 13 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 13 13:28:35 Ambient Measurement Device(s) Being Used, type = None 13:28:35 Magnet Voltage Measurement Device(s) Being Used, type = None 13:28:36 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 13:28:36 XMAG Device(s) Being Used, type = None 13:28:36 Ambient Measurement Device(s) Being Used, type = None 13:28:38   Voltage Measurement, V = 0.000000 V 13:28:39 Temperature Measurement, Probe Number = 0, T = 20.922000 C 13:28:39 Temperature Measurement, Probe Number = 1, T = 21.472000 C 13:28:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.92 P2 = 3458_Meas_Junction, Value = 21.47 13:28:39 Integrated Voltage Measurement... 13:29:05 Voltage Offset Correction: v_off_ini = -0.000001015 V, v_off_fin = -0.000000025 V 13:29:05 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143228300 Vs 13:29:05 Integrated Voltage Measurement... 13:29:40 Voltage Offset Correction: v_off_ini = -0.000000726 V, v_off_fin = -0.000003108 V 13:29:40 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.143184493 Vs 13:29:41   Voltage Measurement, V = 0.000000 V 13:29:41 Temperature Measurement, Probe Number = 0, T = 20.916000 C 13:29:42 Temperature Measurement, Probe Number = 1, T = 21.468000 C 13:29:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.92 P2 = 3458_Meas_Junction, Value = 21.47 13:29:42 Integrated Voltage Measurement... 13:30:14 Voltage Offset Correction: v_off_ini = -0.000001627 V, v_off_fin = -0.000000708 V 13:30:14 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143206990 Vs 13:30:14 Integrated Voltage Measurement... 13:30:46 Voltage Offset Correction: v_off_ini = -0.000000988 V, v_off_fin = -0.000003224 V 13:30:46 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.143200482 Vs 13:30:47   Voltage Measurement, V = 0.000000 V 13:30:47 Temperature Measurement, Probe Number = 0, T = 20.922000 C 13:30:48 Temperature Measurement, Probe Number = 1, T = 21.464000 C 13:30:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.92 P2 = 3458_Meas_Junction, Value = 21.46 13:30:48 Integrated Voltage Measurement... 13:31:20 Voltage Offset Correction: v_off_ini = -0.000001799 V, v_off_fin = 0.000000783 V 13:31:20 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143220364 Vs 13:31:20 Integrated Voltage Measurement... 13:31:52 Voltage Offset Correction: v_off_ini = -0.000000901 V, v_off_fin = -0.000002376 V 13:31:52 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143189175 Vs 13:31:53   Voltage Measurement, V = 0.000000 V 13:31:54 Temperature Measurement, Probe Number = 0, T = 20.940000 C 13:31:55 Temperature Measurement, Probe Number = 1, T = 21.451000 C 13:31:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.94 P2 = 3458_Meas_Junction, Value = 21.45 13:31:55 Integrated Voltage Measurement... 13:32:25 Voltage Offset Correction: v_off_ini = -0.000001944 V, v_off_fin = -0.000000369 V 13:32:25 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143215222 Vs 13:32:25 Integrated Voltage Measurement... 13:32:56 Voltage Offset Correction: v_off_ini = -0.000000924 V, v_off_fin = -0.000003534 V 13:32:56 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.143183666 Vs 13:32:57   Voltage Measurement, V = 0.000000 V 13:32:58 Temperature Measurement, Probe Number = 0, T = 20.949000 C 13:32:58 Temperature Measurement, Probe Number = 1, T = 21.445000 C 13:32:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.95 P2 = 3458_Meas_Junction, Value = 21.45 13:32:58 Integrated Voltage Measurement... 13:33:29 Voltage Offset Correction: v_off_ini = -0.000001703 V, v_off_fin = -0.000001588 V 13:33:29 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143211618 Vs 13:33:29 Integrated Voltage Measurement... 13:34:01 Voltage Offset Correction: v_off_ini = -0.000000891 V, v_off_fin = -0.000002702 V 13:34:01 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143190200 Vs 13:34:02   Voltage Measurement, V = 0.000000 V 13:34:03 Temperature Measurement, Probe Number = 0, T = 20.959000 C 13:34:03 Temperature Measurement, Probe Number = 1, T = 21.454000 C 13:34:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.96 P2 = 3458_Meas_Junction, Value = 21.45 13:34:03 Integrated Voltage Measurement... 13:34:37 Voltage Offset Correction: v_off_ini = -0.000001785 V, v_off_fin = -0.000001119 V 13:34:37 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143217658 Vs 13:34:37 Integrated Voltage Measurement... 13:35:10 Voltage Offset Correction: v_off_ini = -0.000001272 V, v_off_fin = -0.000001928 V 13:35:10 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.143177142 Vs 13:35:11   Voltage Measurement, V = 0.000000 V 13:35:11 Temperature Measurement, Probe Number = 0, T = 20.983000 C 13:35:12 Temperature Measurement, Probe Number = 1, T = 21.463000 C 13:35:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.98 P2 = 3458_Meas_Junction, Value = 21.46 13:35:12 Integrated Voltage Measurement... 13:35:44 Voltage Offset Correction: v_off_ini = -0.000001666 V, v_off_fin = 0.000000237 V 13:35:44 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.143202752 Vs 13:35:44 Integrated Voltage Measurement... 13:36:23 Voltage Offset Correction: v_off_ini = -0.000000942 V, v_off_fin = -0.000002866 V 13:36:23 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143182732 Vs 13:36:24   Voltage Measurement, V = 0.000000 V 13:36:24 Temperature Measurement, Probe Number = 0, T = 21.001000 C 13:36:25 Temperature Measurement, Probe Number = 1, T = 21.460000 C 13:36:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.00 P2 = 3458_Meas_Junction, Value = 21.46 13:36:25 Integrated Voltage Measurement... 13:36:56 Voltage Offset Correction: v_off_ini = -0.000001552 V, v_off_fin = -0.000001038 V 13:36:56 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143212491 Vs 13:36:56 Integrated Voltage Measurement... 13:37:27 Voltage Offset Correction: v_off_ini = -0.000000906 V, v_off_fin = -0.000002562 V 13:37:27 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143192626 Vs 13:37:28   Voltage Measurement, V = 0.000000 V 13:37:28 Temperature Measurement, Probe Number = 0, T = 20.990000 C 13:37:29 Temperature Measurement, Probe Number = 1, T = 21.461000 C 13:37:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.99 P2 = 3458_Meas_Junction, Value = 21.46 13:37:29 Integrated Voltage Measurement... 13:38:00 Voltage Offset Correction: v_off_ini = -0.000001807 V, v_off_fin = -0.000001014 V 13:38:00 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143206879 Vs 13:38:00 Integrated Voltage Measurement... 13:38:33 Voltage Offset Correction: v_off_ini = -0.000001112 V, v_off_fin = -0.000002601 V 13:38:33 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143180855 Vs 13:38:34   Voltage Measurement, V = 0.000000 V 13:38:35 Temperature Measurement, Probe Number = 0, T = 20.974000 C 13:38:35 Temperature Measurement, Probe Number = 1, T = 21.447000 C 13:38:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.97 P2 = 3458_Meas_Junction, Value = 21.45 13:38:35 Integrated Voltage Measurement... 13:39:06 Voltage Offset Correction: v_off_ini = -0.000001825 V, v_off_fin = -0.000000963 V 13:39:06 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143217678 Vs 13:39:06 Integrated Voltage Measurement... 13:39:38 Voltage Offset Correction: v_off_ini = -0.000000743 V, v_off_fin = -0.000003026 V 13:39:38 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.143182103 Vs