SLAC Magnetic Measurements Date: 12-01-2020 Time: 13:37:04 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_009_Cell_36_Upstairs Serial Number: PC33408 Run Number: 7 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement upstairs, cable through switch. Full Set 7 13:37:23 Ambient Measurement Device(s) Being Used, type = None 13:37:23 Magnet Voltage Measurement Device(s) Being Used, type = None 13:37:23 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 13:37:23 XMAG Device(s) Being Used, type = None 13:37:23 Ambient Measurement Device(s) Being Used, type = None 13:37:28   Voltage Measurement, V = 0.000000 V 13:37:29 Temperature Measurement, Probe Number = 0, T = 24.312000 C 13:37:30 Temperature Measurement, Probe Number = 1, T = 24.903000 C 13:37:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 24.31 P2 = 3458_Meas_Junction, Value = 24.90 13:37:30 Integrated Voltage Measurement... 13:37:56 Voltage Offset Correction: v_off_ini = 0.000002244 V, v_off_fin = 0.000004645 V 13:37:56 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143381159 Vs 13:37:56 Integrated Voltage Measurement... 13:38:27 Voltage Offset Correction: v_off_ini = 0.000004789 V, v_off_fin = 0.000000768 V 13:38:27 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143341321 Vs 13:38:28   Voltage Measurement, V = 0.000000 V 13:38:29 Temperature Measurement, Probe Number = 0, T = 24.281000 C 13:38:29 Temperature Measurement, Probe Number = 1, T = 24.856000 C 13:38:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 24.28 P2 = 3458_Meas_Junction, Value = 24.86 13:38:29 Integrated Voltage Measurement... 13:39:06 Voltage Offset Correction: v_off_ini = 0.000002977 V, v_off_fin = 0.000004703 V 13:39:06 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.143393427 Vs 13:39:06 Integrated Voltage Measurement... 13:39:36 Voltage Offset Correction: v_off_ini = 0.000004924 V, v_off_fin = 0.000001868 V 13:39:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143343770 Vs 13:39:37   Voltage Measurement, V = 0.000000 V 13:39:38 Temperature Measurement, Probe Number = 0, T = 24.293000 C 13:39:38 Temperature Measurement, Probe Number = 1, T = 24.845000 C 13:39:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 24.29 P2 = 3458_Meas_Junction, Value = 24.84 13:39:38 Integrated Voltage Measurement... 13:40:10 Voltage Offset Correction: v_off_ini = 0.000002878 V, v_off_fin = 0.000005210 V 13:40:10 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.143398845 Vs 13:40:10 Integrated Voltage Measurement... 13:40:44 Voltage Offset Correction: v_off_ini = 0.000004669 V, v_off_fin = 0.000000049 V 13:40:44 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143341661 Vs 13:40:45   Voltage Measurement, V = 0.000000 V 13:40:46 Temperature Measurement, Probe Number = 0, T = 24.302000 C 13:40:46 Temperature Measurement, Probe Number = 1, T = 24.849000 C 13:40:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 24.30 P2 = 3458_Meas_Junction, Value = 24.85 13:40:46 Integrated Voltage Measurement... 13:41:20 Voltage Offset Correction: v_off_ini = 0.000002760 V, v_off_fin = 0.000005547 V 13:41:20 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.143403505 Vs 13:41:20 Integrated Voltage Measurement... 13:41:51 Voltage Offset Correction: v_off_ini = 0.000004601 V, v_off_fin = -0.000001410 V 13:41:51 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143361316 Vs 13:41:52   Voltage Measurement, V = 0.000000 V 13:41:53 Temperature Measurement, Probe Number = 0, T = 24.311000 C 13:41:54 Temperature Measurement, Probe Number = 1, T = 24.854000 C 13:41:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 24.31 P2 = 3458_Meas_Junction, Value = 24.85 13:41:54 Integrated Voltage Measurement... 13:42:28 Voltage Offset Correction: v_off_ini = 0.000002893 V, v_off_fin = 0.000005582 V 13:42:28 Integrated Voltage Measurement Delta Gap = 0.0040018 m VT = 0.143412540 Vs 13:42:28 Integrated Voltage Measurement... 13:43:08 Voltage Offset Correction: v_off_ini = 0.000004674 V, v_off_fin = 0.000000763 V 13:43:08 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143345764 Vs 13:43:09   Voltage Measurement, V = 0.000000 V 13:43:09 Temperature Measurement, Probe Number = 0, T = 24.318000 C 13:43:10 Temperature Measurement, Probe Number = 1, T = 24.860000 C 13:43:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 24.32 P2 = 3458_Meas_Junction, Value = 24.86 13:43:10 Integrated Voltage Measurement... 13:43:42 Voltage Offset Correction: v_off_ini = 0.000002674 V, v_off_fin = 0.000003956 V 13:43:42 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143399153 Vs 13:43:42 Integrated Voltage Measurement... 13:44:16 Voltage Offset Correction: v_off_ini = 0.000004884 V, v_off_fin = 0.000000229 V 13:44:16 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143342592 Vs 13:44:17   Voltage Measurement, V = 0.000000 V 13:44:18 Temperature Measurement, Probe Number = 0, T = 24.314000 C 13:44:18 Temperature Measurement, Probe Number = 1, T = 24.834000 C 13:44:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 24.31 P2 = 3458_Meas_Junction, Value = 24.83 13:44:18 Integrated Voltage Measurement... 13:44:51 Voltage Offset Correction: v_off_ini = 0.000002919 V, v_off_fin = 0.000005670 V 13:44:51 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.143398955 Vs 13:44:51 Integrated Voltage Measurement... 13:45:30 Voltage Offset Correction: v_off_ini = 0.000004780 V, v_off_fin = 0.000000698 V 13:45:30 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.143349817 Vs 13:45:31   Voltage Measurement, V = 0.000000 V 13:45:32 Temperature Measurement, Probe Number = 0, T = 24.311000 C 13:45:32 Temperature Measurement, Probe Number = 1, T = 24.822000 C 13:45:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 24.31 P2 = 3458_Meas_Junction, Value = 24.82 13:45:32 Integrated Voltage Measurement... 13:46:13 Voltage Offset Correction: v_off_ini = 0.000003171 V, v_off_fin = 0.000005323 V 13:46:13 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.143397774 Vs 13:46:13 Integrated Voltage Measurement... 13:46:52 Voltage Offset Correction: v_off_ini = 0.000004693 V, v_off_fin = 0.000000351 V 13:46:52 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143346628 Vs 13:46:53   Voltage Measurement, V = 0.000000 V 13:46:54 Temperature Measurement, Probe Number = 0, T = 24.321000 C 13:46:54 Temperature Measurement, Probe Number = 1, T = 24.851000 C 13:46:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 24.32 P2 = 3458_Meas_Junction, Value = 24.85 13:46:54 Integrated Voltage Measurement... 13:47:28 Voltage Offset Correction: v_off_ini = 0.000002871 V, v_off_fin = 0.000005278 V 13:47:29 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.143412336 Vs 13:47:29 Integrated Voltage Measurement... 13:48:01 Voltage Offset Correction: v_off_ini = 0.000004751 V, v_off_fin = 0.000000132 V 13:48:01 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143354239 Vs 13:48:02   Voltage Measurement, V = 0.000000 V 13:48:03 Temperature Measurement, Probe Number = 0, T = 24.338000 C 13:48:04 Temperature Measurement, Probe Number = 1, T = 24.835000 C 13:48:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 24.34 P2 = 3458_Meas_Junction, Value = 24.84 13:48:04 Integrated Voltage Measurement... 13:48:42 Voltage Offset Correction: v_off_ini = 0.000003125 V, v_off_fin = 0.000004873 V 13:48:42 Integrated Voltage Measurement Delta Gap = 0.0040018 m VT = 0.143416119 Vs 13:48:42 Integrated Voltage Measurement... 13:49:13 Voltage Offset Correction: v_off_ini = 0.000004882 V, v_off_fin = 0.000000882 V 13:49:13 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143337903 Vs