SLAC Magnetic Measurements Date: 01-07-2021 Time: 15:14:48 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_009_Cell_36 Serial Number: PC33408 Run Number: 15 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 15 15:15:06 Ambient Measurement Device(s) Being Used, type = None 15:15:06 Magnet Voltage Measurement Device(s) Being Used, type = None 15:15:06 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:15:06 XMAG Device(s) Being Used, type = None 15:15:06 Ambient Measurement Device(s) Being Used, type = None 15:15:15   Voltage Measurement, V = 0.000000 V 15:15:15 Temperature Measurement, Probe Number = 0, T = 20.737000 C 15:15:16 Temperature Measurement, Probe Number = 1, T = 21.738000 C 15:15:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.74 P2 = 3458_Meas_Junction, Value = 21.74 15:15:16 Integrated Voltage Measurement... 15:15:42 Voltage Offset Correction: v_off_ini = 0.000000245 V, v_off_fin = 0.000001073 V 15:15:42 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143380616 Vs 15:15:42 Integrated Voltage Measurement... 15:16:28 Voltage Offset Correction: v_off_ini = 0.000000499 V, v_off_fin = -0.000004703 V 15:16:28 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143371236 Vs 15:16:29   Voltage Measurement, V = 0.000000 V 15:16:30 Temperature Measurement, Probe Number = 0, T = 20.743000 C 15:16:31 Temperature Measurement, Probe Number = 1, T = 21.731000 C 15:16:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.74 P2 = 3458_Meas_Junction, Value = 21.73 15:16:31 Integrated Voltage Measurement... 15:17:04 Voltage Offset Correction: v_off_ini = -0.000000997 V, v_off_fin = 0.000001037 V 15:17:04 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143419615 Vs 15:17:04 Integrated Voltage Measurement... 15:17:42 Voltage Offset Correction: v_off_ini = 0.000000694 V, v_off_fin = -0.000002084 V 15:17:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143353555 Vs 15:17:43   Voltage Measurement, V = 0.000000 V 15:17:43 Temperature Measurement, Probe Number = 0, T = 20.757000 C 15:17:44 Temperature Measurement, Probe Number = 1, T = 21.742000 C 15:17:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.76 P2 = 3458_Meas_Junction, Value = 21.74 15:17:44 Integrated Voltage Measurement... 15:18:15 Voltage Offset Correction: v_off_ini = -0.000001032 V, v_off_fin = 0.000000558 V 15:18:15 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143394660 Vs 15:18:15 Integrated Voltage Measurement... 15:18:49 Voltage Offset Correction: v_off_ini = 0.000000773 V, v_off_fin = -0.000003246 V 15:18:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143359283 Vs 15:18:50   Voltage Measurement, V = 0.000000 V 15:18:50 Temperature Measurement, Probe Number = 0, T = 20.761000 C 15:18:51 Temperature Measurement, Probe Number = 1, T = 21.745000 C 15:18:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.76 P2 = 3458_Meas_Junction, Value = 21.75 15:18:51 Integrated Voltage Measurement... 15:19:22 Voltage Offset Correction: v_off_ini = -0.000001323 V, v_off_fin = 0.000001178 V 15:19:22 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.143426340 Vs 15:19:22 Integrated Voltage Measurement... 15:19:53 Voltage Offset Correction: v_off_ini = 0.000000823 V, v_off_fin = -0.000002411 V 15:19:53 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143375132 Vs 15:19:54   Voltage Measurement, V = 0.000000 V 15:19:55 Temperature Measurement, Probe Number = 0, T = 20.771000 C 15:19:56 Temperature Measurement, Probe Number = 1, T = 21.739000 C 15:19:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.77 P2 = 3458_Meas_Junction, Value = 21.74 15:19:56 Integrated Voltage Measurement... 15:20:27 Voltage Offset Correction: v_off_ini = -0.000001415 V, v_off_fin = 0.000001784 V 15:20:27 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143428664 Vs 15:20:27 Integrated Voltage Measurement... 15:20:58 Voltage Offset Correction: v_off_ini = 0.000000788 V, v_off_fin = -0.000002976 V 15:20:58 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143373044 Vs 15:20:59   Voltage Measurement, V = 0.000000 V 15:21:00 Temperature Measurement, Probe Number = 0, T = 20.770000 C 15:21:00 Temperature Measurement, Probe Number = 1, T = 21.744000 C 15:21:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.77 P2 = 3458_Meas_Junction, Value = 21.74 15:21:00 Integrated Voltage Measurement... 15:21:32 Voltage Offset Correction: v_off_ini = -0.000001230 V, v_off_fin = 0.000001616 V 15:21:32 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.143417031 Vs 15:21:32 Integrated Voltage Measurement... 15:22:03 Voltage Offset Correction: v_off_ini = 0.000000697 V, v_off_fin = -0.000003193 V 15:22:03 Integrated Voltage Measurement Delta Gap = -0.0040013 m VT = -0.143386454 Vs 15:22:04   Voltage Measurement, V = 0.000000 V 15:22:05 Temperature Measurement, Probe Number = 0, T = 20.770000 C 15:22:05 Temperature Measurement, Probe Number = 1, T = 21.746000 C 15:22:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.77 P2 = 3458_Meas_Junction, Value = 21.75 15:22:05 Integrated Voltage Measurement... 15:22:37 Voltage Offset Correction: v_off_ini = -0.000001203 V, v_off_fin = 0.000000759 V 15:22:37 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.143430131 Vs 15:22:37 Integrated Voltage Measurement... 15:23:07 Voltage Offset Correction: v_off_ini = 0.000001002 V, v_off_fin = -0.000004120 V 15:23:07 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143380108 Vs 15:23:08   Voltage Measurement, V = 0.000000 V 15:23:09 Temperature Measurement, Probe Number = 0, T = 20.764000 C 15:23:10 Temperature Measurement, Probe Number = 1, T = 21.750000 C 15:23:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.76 P2 = 3458_Meas_Junction, Value = 21.75 15:23:10 Integrated Voltage Measurement... 15:23:43 Voltage Offset Correction: v_off_ini = -0.000001050 V, v_off_fin = 0.000001360 V 15:23:43 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.143443087 Vs 15:23:43 Integrated Voltage Measurement... 15:24:14 Voltage Offset Correction: v_off_ini = 0.000001018 V, v_off_fin = -0.000003152 V 15:24:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143370430 Vs 15:24:15   Voltage Measurement, V = 0.000000 V 15:24:15 Temperature Measurement, Probe Number = 0, T = 20.764000 C 15:24:16 Temperature Measurement, Probe Number = 1, T = 21.754000 C 15:24:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.76 P2 = 3458_Meas_Junction, Value = 21.75 15:24:16 Integrated Voltage Measurement... 15:24:48 Voltage Offset Correction: v_off_ini = -0.000001039 V, v_off_fin = 0.000002159 V 15:24:48 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143414022 Vs 15:24:48 Integrated Voltage Measurement... 15:25:19 Voltage Offset Correction: v_off_ini = 0.000000802 V, v_off_fin = -0.000003496 V 15:25:19 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143371818 Vs 15:25:20   Voltage Measurement, V = 0.000000 V 15:25:21 Temperature Measurement, Probe Number = 0, T = 20.770000 C 15:25:21 Temperature Measurement, Probe Number = 1, T = 21.755000 C 15:25:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.77 P2 = 3458_Meas_Junction, Value = 21.75 15:25:21 Integrated Voltage Measurement... 15:25:53 Voltage Offset Correction: v_off_ini = -0.000001255 V, v_off_fin = 0.000001150 V 15:25:53 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143424484 Vs 15:25:53 Integrated Voltage Measurement... 15:26:24 Voltage Offset Correction: v_off_ini = 0.000001072 V, v_off_fin = -0.000003447 V 15:26:24 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143380374 Vs