SLAC Magnetic Measurements Date: 10-21-2020 Time: 12:38:51 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_003_Cell_36 Serial Number: PC33408 Run Number: 11 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 11 12:39:09 Ambient Measurement Device(s) Being Used, type = None 12:39:09 Magnet Voltage Measurement Device(s) Being Used, type = None 12:39:10 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 12:39:10 XMAG Device(s) Being Used, type = None 12:39:10 Ambient Measurement Device(s) Being Used, type = None 12:39:14   Voltage Measurement, V = 0.000000 V 12:39:15 Temperature Measurement, Probe Number = 0, T = 21.111000 C 12:39:16 Temperature Measurement, Probe Number = 1, T = 20.314000 C 12:39:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.11 P2 = 3458_Meas_Junction, Value = 20.31 12:39:16 Integrated Voltage Measurement... 12:39:42 Voltage Offset Correction: v_off_ini = -0.000000272 V, v_off_fin = 0.000000861 V 12:39:42 Integrated Voltage Measurement Delta Gap = 0.0040020 m VT = 0.143443732 Vs 12:39:42 Integrated Voltage Measurement... 12:40:15 Voltage Offset Correction: v_off_ini = 0.000000457 V, v_off_fin = -0.000003982 V 12:40:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143400011 Vs 12:40:16   Voltage Measurement, V = 0.000000 V 12:40:17 Temperature Measurement, Probe Number = 0, T = 21.087000 C 12:40:17 Temperature Measurement, Probe Number = 1, T = 20.284000 C 12:40:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.09 P2 = 3458_Meas_Junction, Value = 20.28 12:40:17 Integrated Voltage Measurement... 12:40:49 Voltage Offset Correction: v_off_ini = -0.000001913 V, v_off_fin = 0.000001051 V 12:40:49 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.143444324 Vs 12:40:49 Integrated Voltage Measurement... 12:41:20 Voltage Offset Correction: v_off_ini = 0.000000100 V, v_off_fin = -0.000005031 V 12:41:20 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143393764 Vs 12:41:21   Voltage Measurement, V = 0.000000 V 12:41:22 Temperature Measurement, Probe Number = 0, T = 21.090000 C 12:41:22 Temperature Measurement, Probe Number = 1, T = 20.290000 C 12:41:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.09 P2 = 3458_Meas_Junction, Value = 20.29 12:41:22 Integrated Voltage Measurement... 12:41:54 Voltage Offset Correction: v_off_ini = -0.000001468 V, v_off_fin = 0.000001329 V 12:41:54 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.143433176 Vs 12:41:54 Integrated Voltage Measurement... 12:42:26 Voltage Offset Correction: v_off_ini = 0.000000134 V, v_off_fin = -0.000003971 V 12:42:26 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143386864 Vs 12:42:27   Voltage Measurement, V = 0.000000 V 12:42:27 Temperature Measurement, Probe Number = 0, T = 21.096000 C 12:42:28 Temperature Measurement, Probe Number = 1, T = 20.299000 C 12:42:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.10 P2 = 3458_Meas_Junction, Value = 20.30 12:42:28 Integrated Voltage Measurement... 12:42:59 Voltage Offset Correction: v_off_ini = -0.000002096 V, v_off_fin = -0.000000064 V 12:42:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143435920 Vs 12:42:59 Integrated Voltage Measurement... 12:43:31 Voltage Offset Correction: v_off_ini = 0.000000278 V, v_off_fin = -0.000003302 V 12:43:31 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143389302 Vs 12:43:32   Voltage Measurement, V = 0.000000 V 12:43:32 Temperature Measurement, Probe Number = 0, T = 21.099000 C 12:43:33 Temperature Measurement, Probe Number = 1, T = 20.274000 C 12:43:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.10 P2 = 3458_Meas_Junction, Value = 20.27 12:43:33 Integrated Voltage Measurement... 12:44:06 Voltage Offset Correction: v_off_ini = -0.000001801 V, v_off_fin = 0.000001071 V 12:44:06 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.143448472 Vs 12:44:06 Integrated Voltage Measurement... 12:44:37 Voltage Offset Correction: v_off_ini = 0.000000208 V, v_off_fin = -0.000004156 V 12:44:37 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143381380 Vs 12:44:38   Voltage Measurement, V = 0.000000 V 12:44:39 Temperature Measurement, Probe Number = 0, T = 21.092000 C 12:44:39 Temperature Measurement, Probe Number = 1, T = 20.287000 C 12:44:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.09 P2 = 3458_Meas_Junction, Value = 20.29 12:44:39 Integrated Voltage Measurement... 12:45:17 Voltage Offset Correction: v_off_ini = -0.000001326 V, v_off_fin = 0.000000221 V 12:45:17 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143415558 Vs 12:45:17 Integrated Voltage Measurement... 12:45:48 Voltage Offset Correction: v_off_ini = 0.000000121 V, v_off_fin = -0.000004551 V 12:45:48 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143386939 Vs 12:45:49   Voltage Measurement, V = 0.000000 V 12:45:50 Temperature Measurement, Probe Number = 0, T = 21.080000 C 12:45:51 Temperature Measurement, Probe Number = 1, T = 20.285000 C 12:45:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.08 P2 = 3458_Meas_Junction, Value = 20.29 12:45:51 Integrated Voltage Measurement... 12:46:25 Voltage Offset Correction: v_off_ini = -0.000001453 V, v_off_fin = 0.000000859 V 12:46:25 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.143449525 Vs 12:46:25 Integrated Voltage Measurement... 12:47:01 Voltage Offset Correction: v_off_ini = -0.000000080 V, v_off_fin = -0.000004234 V 12:47:01 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.143400743 Vs 12:47:02   Voltage Measurement, V = 0.000000 V 12:47:03 Temperature Measurement, Probe Number = 0, T = 21.073000 C 12:47:03 Temperature Measurement, Probe Number = 1, T = 20.327000 C 12:47:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.07 P2 = 3458_Meas_Junction, Value = 20.33 12:47:03 Integrated Voltage Measurement... 12:47:35 Voltage Offset Correction: v_off_ini = -0.000001890 V, v_off_fin = 0.000001111 V 12:47:35 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.143457184 Vs 12:47:35 Integrated Voltage Measurement... 12:48:13 Voltage Offset Correction: v_off_ini = 0.000000005 V, v_off_fin = -0.000004488 V 12:48:13 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.143394655 Vs 12:48:14   Voltage Measurement, V = 0.000000 V 12:48:15 Temperature Measurement, Probe Number = 0, T = 21.070000 C 12:48:15 Temperature Measurement, Probe Number = 1, T = 20.329000 C 12:48:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.07 P2 = 3458_Meas_Junction, Value = 20.33 12:48:15 Integrated Voltage Measurement... 12:48:48 Voltage Offset Correction: v_off_ini = -0.000001901 V, v_off_fin = -0.000000134 V 12:48:48 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.143446971 Vs 12:48:48 Integrated Voltage Measurement... 12:49:34 Voltage Offset Correction: v_off_ini = -0.000000038 V, v_off_fin = -0.000003568 V 12:49:34 Integrated Voltage Measurement Delta Gap = -0.0040014 m VT = -0.143400956 Vs 12:49:35   Voltage Measurement, V = 0.000000 V 12:49:36 Temperature Measurement, Probe Number = 0, T = 21.083000 C 12:49:37 Temperature Measurement, Probe Number = 1, T = 20.280000 C 12:49:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.08 P2 = 3458_Meas_Junction, Value = 20.28 12:49:37 Integrated Voltage Measurement... 12:50:07 Voltage Offset Correction: v_off_ini = -0.000002022 V, v_off_fin = 0.000000928 V 12:50:07 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.143451431 Vs 12:50:07 Integrated Voltage Measurement... 12:50:41 Voltage Offset Correction: v_off_ini = 0.000000033 V, v_off_fin = -0.000003034 V 12:50:41 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143377455 Vs