SLAC Magnetic Measurements Date: 01-06-2021 Time: 11:08:25 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_008_Cell_38_Upstairs Serial Number: PC97084 Run Number: 8 Measurement Device: WalkerVs Operator: sda Comment: Coil Integral measurement upstairs, cable through switch. Full Set 8 11:08:44 Ambient Measurement Device(s) Being Used, type = None 11:08:44 Magnet Voltage Measurement Device(s) Being Used, type = None 11:08:44 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 11:08:44 XMAG Device(s) Being Used, type = None 11:08:44 Ambient Measurement Device(s) Being Used, type = None 11:08:59   Voltage Measurement, V = 0.000000 V 11:08:59 Temperature Measurement, Probe Number = 0, T = 27.558000 C 11:09:00 Temperature Measurement, Probe Number = 1, T = 27.051000 C 11:09:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.56 P2 = 3458_Meas_Junction, Value = 27.05 11:09:00 Integrated Voltage Measurement... 11:09:37 Voltage Offset Correction: v_off_ini = 0.000002295 V, v_off_fin = 0.000004875 V 11:09:37 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.142815631 Vs 11:09:37 Integrated Voltage Measurement... 11:10:20 Voltage Offset Correction: v_off_ini = 0.000003938 V, v_off_fin = 0.000001739 V 11:10:20 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142790379 Vs 11:10:21   Voltage Measurement, V = 0.000000 V 11:10:22 Temperature Measurement, Probe Number = 0, T = 27.548000 C 11:10:22 Temperature Measurement, Probe Number = 1, T = 27.044000 C 11:10:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.55 P2 = 3458_Meas_Junction, Value = 27.04 11:10:22 Integrated Voltage Measurement... 11:10:57 Voltage Offset Correction: v_off_ini = 0.000002667 V, v_off_fin = 0.000004123 V 11:10:57 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142820165 Vs 11:10:57 Integrated Voltage Measurement... 11:11:27 Voltage Offset Correction: v_off_ini = 0.000003944 V, v_off_fin = 0.000002650 V 11:11:27 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142782826 Vs 11:11:28   Voltage Measurement, V = 0.000000 V 11:11:29 Temperature Measurement, Probe Number = 0, T = 27.549000 C 11:11:30 Temperature Measurement, Probe Number = 1, T = 27.049000 C 11:11:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.55 P2 = 3458_Meas_Junction, Value = 27.05 11:11:30 Integrated Voltage Measurement... 11:12:00 Voltage Offset Correction: v_off_ini = 0.000003002 V, v_off_fin = 0.000004271 V 11:12:00 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142820160 Vs 11:12:00 Integrated Voltage Measurement... 11:12:32 Voltage Offset Correction: v_off_ini = 0.000004084 V, v_off_fin = 0.000002438 V 11:12:32 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142801756 Vs 11:12:33   Voltage Measurement, V = 0.000000 V 11:12:34 Temperature Measurement, Probe Number = 0, T = 27.549000 C 11:12:34 Temperature Measurement, Probe Number = 1, T = 27.042000 C 11:12:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.55 P2 = 3458_Meas_Junction, Value = 27.04 11:12:34 Integrated Voltage Measurement... 11:13:06 Voltage Offset Correction: v_off_ini = 0.000002921 V, v_off_fin = 0.000003911 V 11:13:06 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142827369 Vs 11:13:06 Integrated Voltage Measurement... 11:13:38 Voltage Offset Correction: v_off_ini = 0.000003864 V, v_off_fin = 0.000002210 V 11:13:38 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142787366 Vs 11:13:39   Voltage Measurement, V = 0.000000 V 11:13:39 Temperature Measurement, Probe Number = 0, T = 27.550000 C 11:13:40 Temperature Measurement, Probe Number = 1, T = 27.045000 C 11:13:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.55 P2 = 3458_Meas_Junction, Value = 27.05 11:13:40 Integrated Voltage Measurement... 11:14:16 Voltage Offset Correction: v_off_ini = 0.000003076 V, v_off_fin = 0.000004229 V 11:14:16 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142824252 Vs 11:14:16 Integrated Voltage Measurement... 11:14:50 Voltage Offset Correction: v_off_ini = 0.000004113 V, v_off_fin = 0.000001435 V 11:14:50 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142785928 Vs 11:14:51   Voltage Measurement, V = 0.000000 V 11:14:52 Temperature Measurement, Probe Number = 0, T = 27.551000 C 11:14:52 Temperature Measurement, Probe Number = 1, T = 27.051000 C 11:14:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.55 P2 = 3458_Meas_Junction, Value = 27.05 11:14:52 Integrated Voltage Measurement... 11:15:23 Voltage Offset Correction: v_off_ini = 0.000002537 V, v_off_fin = 0.000004343 V 11:15:23 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142830322 Vs 11:15:23 Integrated Voltage Measurement... 11:15:57 Voltage Offset Correction: v_off_ini = 0.000004134 V, v_off_fin = 0.000002098 V 11:15:57 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142800993 Vs 11:15:58   Voltage Measurement, V = 0.000000 V 11:15:59 Temperature Measurement, Probe Number = 0, T = 27.552000 C 11:15:59 Temperature Measurement, Probe Number = 1, T = 27.049000 C 11:15:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.55 P2 = 3458_Meas_Junction, Value = 27.05 11:15:59 Integrated Voltage Measurement... 11:16:31 Voltage Offset Correction: v_off_ini = 0.000002763 V, v_off_fin = 0.000004762 V 11:16:31 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142832758 Vs 11:16:31 Integrated Voltage Measurement... 11:17:02 Voltage Offset Correction: v_off_ini = 0.000004176 V, v_off_fin = 0.000002436 V 11:17:02 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142787937 Vs 11:17:03   Voltage Measurement, V = 0.000000 V 11:17:04 Temperature Measurement, Probe Number = 0, T = 27.553000 C 11:17:04 Temperature Measurement, Probe Number = 1, T = 27.053000 C 11:17:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.55 P2 = 3458_Meas_Junction, Value = 27.05 11:17:04 Integrated Voltage Measurement... 11:17:36 Voltage Offset Correction: v_off_ini = 0.000002964 V, v_off_fin = 0.000004844 V 11:17:36 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142835475 Vs 11:17:36 Integrated Voltage Measurement... 11:18:11 Voltage Offset Correction: v_off_ini = 0.000003909 V, v_off_fin = 0.000001986 V 11:18:12 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142789675 Vs 11:18:13   Voltage Measurement, V = 0.000000 V 11:18:13 Temperature Measurement, Probe Number = 0, T = 27.559000 C 11:18:14 Temperature Measurement, Probe Number = 1, T = 27.062000 C 11:18:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.56 P2 = 3458_Meas_Junction, Value = 27.06 11:18:14 Integrated Voltage Measurement... 11:18:47 Voltage Offset Correction: v_off_ini = 0.000002764 V, v_off_fin = 0.000004035 V 11:18:47 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142822560 Vs 11:18:47 Integrated Voltage Measurement... 11:19:21 Voltage Offset Correction: v_off_ini = 0.000004106 V, v_off_fin = 0.000001832 V 11:19:21 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142789350 Vs 11:19:22   Voltage Measurement, V = 0.000000 V 11:19:23 Temperature Measurement, Probe Number = 0, T = 27.563000 C 11:19:23 Temperature Measurement, Probe Number = 1, T = 27.063000 C 11:19:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.56 P2 = 3458_Meas_Junction, Value = 27.06 11:19:23 Integrated Voltage Measurement... 11:19:54 Voltage Offset Correction: v_off_ini = 0.000002596 V, v_off_fin = 0.000004409 V 11:19:54 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142835017 Vs 11:19:54 Integrated Voltage Measurement... 11:20:34 Voltage Offset Correction: v_off_ini = 0.000003902 V, v_off_fin = 0.000001742 V 11:20:34 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142791251 Vs