SLAC Magnetic Measurements Date: 09-08-2020 Time: 16:51:43 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_008_Cell_38 Serial Number: HP_PC33408 Run Number: 8 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 8 16:51:46 Ambient Measurement Device(s) Being Used, type = None 16:51:46 Magnet Voltage Measurement Device(s) Being Used, type = None 16:51:46 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 16:51:46 XMAG Device(s) Being Used, type = None 16:51:46 Ambient Measurement Device(s) Being Used, type = None 16:51:56   Voltage Measurement, V = 0.000000 V 16:51:56 Temperature Measurement, Probe Number = 0, T = 21.752000 C 16:51:57 Temperature Measurement, Probe Number = 1, T = 22.715000 C 16:51:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.75 P2 = 3458_Meas_Junction, Value = 22.71 16:51:57 Integrated Voltage Measurement... 16:52:25 Voltage Offset Correction: v_off_ini = 0.000000281 V, v_off_fin = 0.000001047 V 16:52:25 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142780043 Vs 16:52:25 Integrated Voltage Measurement... 16:53:10 Voltage Offset Correction: v_off_ini = 0.000000466 V, v_off_fin = -0.000001822 V 16:53:10 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142759579 Vs 16:53:11   Voltage Measurement, V = 0.000000 V 16:53:12 Temperature Measurement, Probe Number = 0, T = 21.741000 C 16:53:13 Temperature Measurement, Probe Number = 1, T = 22.728000 C 16:53:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.74 P2 = 3458_Meas_Junction, Value = 22.73 16:53:13 Integrated Voltage Measurement... 16:53:47 Voltage Offset Correction: v_off_ini = -0.000000384 V, v_off_fin = 0.000000372 V 16:53:47 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142774947 Vs 16:53:47 Integrated Voltage Measurement... 16:54:17 Voltage Offset Correction: v_off_ini = 0.000000976 V, v_off_fin = -0.000002555 V 16:54:17 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142758583 Vs 16:54:18   Voltage Measurement, V = 0.000000 V 16:54:18 Temperature Measurement, Probe Number = 0, T = 21.740000 C 16:54:19 Temperature Measurement, Probe Number = 1, T = 22.736000 C 16:54:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.74 P2 = 3458_Meas_Junction, Value = 22.74 16:54:19 Integrated Voltage Measurement... 16:54:51 Voltage Offset Correction: v_off_ini = -0.000000928 V, v_off_fin = 0.000000304 V 16:54:51 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142772506 Vs 16:54:51 Integrated Voltage Measurement... 16:55:16 Voltage Offset Correction: v_off_ini = 0.000000866 V, v_off_fin = -0.000002709 V 16:55:16 Integrated Voltage Measurement Delta Gap = 0.0000002 m VT = -0.142731925 Vs 16:55:17   Voltage Measurement, V = 0.000000 V 16:55:18 Temperature Measurement, Probe Number = 0, T = 21.750000 C 16:55:19 Temperature Measurement, Probe Number = 1, T = 22.744000 C 16:55:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.75 P2 = 3458_Meas_Junction, Value = 22.74 16:55:19 Integrated Voltage Measurement... 16:55:57 Voltage Offset Correction: v_off_ini = -0.000000889 V, v_off_fin = 0.000001421 V 16:55:57 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142768931 Vs 16:55:57 Integrated Voltage Measurement... 16:56:29 Voltage Offset Correction: v_off_ini = 0.000000526 V, v_off_fin = -0.000002110 V 16:56:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142757443 Vs 16:56:31   Voltage Measurement, V = 0.000000 V 16:56:31 Temperature Measurement, Probe Number = 0, T = 21.768000 C 16:56:32 Temperature Measurement, Probe Number = 1, T = 22.759000 C 16:56:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.77 P2 = 3458_Meas_Junction, Value = 22.76 16:56:32 Integrated Voltage Measurement... 16:57:03 Voltage Offset Correction: v_off_ini = -0.000000706 V, v_off_fin = 0.000001848 V 16:57:03 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142763998 Vs 16:57:03 Integrated Voltage Measurement... 16:57:34 Voltage Offset Correction: v_off_ini = 0.000000383 V, v_off_fin = -0.000001467 V 16:57:34 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142760981 Vs 16:57:35   Voltage Measurement, V = 0.000000 V 16:57:36 Temperature Measurement, Probe Number = 0, T = 21.779000 C 16:57:36 Temperature Measurement, Probe Number = 1, T = 22.771000 C 16:57:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.78 P2 = 3458_Meas_Junction, Value = 22.77 16:57:36 Integrated Voltage Measurement... 16:58:11 Voltage Offset Correction: v_off_ini = -0.000000795 V, v_off_fin = 0.000002397 V 16:58:11 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142766256 Vs 16:58:11 Integrated Voltage Measurement... 16:58:44 Voltage Offset Correction: v_off_ini = 0.000000322 V, v_off_fin = -0.000002202 V 16:58:44 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.142765399 Vs 16:58:45   Voltage Measurement, V = 0.000000 V 16:58:45 Temperature Measurement, Probe Number = 0, T = 21.789000 C 16:58:46 Temperature Measurement, Probe Number = 1, T = 22.764000 C 16:58:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.79 P2 = 3458_Meas_Junction, Value = 22.76 16:58:46 Integrated Voltage Measurement... 16:59:18 Voltage Offset Correction: v_off_ini = -0.000000917 V, v_off_fin = 0.000000973 V 16:59:18 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142750912 Vs 16:59:18 Integrated Voltage Measurement... 16:59:58 Voltage Offset Correction: v_off_ini = 0.000000219 V, v_off_fin = -0.000002008 V 16:59:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142760792 Vs 16:59:59   Voltage Measurement, V = 0.000000 V 17:00:00 Temperature Measurement, Probe Number = 0, T = 21.791000 C 17:00:00 Temperature Measurement, Probe Number = 1, T = 22.784000 C 17:00:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.79 P2 = 3458_Meas_Junction, Value = 22.78 17:00:00 Integrated Voltage Measurement... 17:00:31 Voltage Offset Correction: v_off_ini = -0.000000882 V, v_off_fin = 0.000002041 V 17:00:31 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142773423 Vs 17:00:31 Integrated Voltage Measurement... 17:01:01 Voltage Offset Correction: v_off_ini = 0.000000660 V, v_off_fin = -0.000002185 V 17:01:01 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142766663 Vs 17:01:02   Voltage Measurement, V = 0.000000 V 17:01:03 Temperature Measurement, Probe Number = 0, T = 21.805000 C 17:01:03 Temperature Measurement, Probe Number = 1, T = 22.789000 C 17:01:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.80 P2 = 3458_Meas_Junction, Value = 22.79 17:01:03 Integrated Voltage Measurement... 17:01:35 Voltage Offset Correction: v_off_ini = -0.000000600 V, v_off_fin = 0.000000416 V 17:01:35 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142781828 Vs 17:01:35 Integrated Voltage Measurement... 17:02:06 Voltage Offset Correction: v_off_ini = 0.000000557 V, v_off_fin = -0.000001925 V 17:02:06 Integrated Voltage Measurement Delta Gap = -0.0040013 m VT = -0.142764468 Vs 17:02:07   Voltage Measurement, V = 0.000000 V 17:02:07 Temperature Measurement, Probe Number = 0, T = 21.819000 C 17:02:08 Temperature Measurement, Probe Number = 1, T = 22.789000 C 17:02:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.82 P2 = 3458_Meas_Junction, Value = 22.79 17:02:08 Integrated Voltage Measurement... 17:02:40 Voltage Offset Correction: v_off_ini = -0.000000795 V, v_off_fin = 0.000002081 V 17:02:40 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142767158 Vs 17:02:40 Integrated Voltage Measurement... 17:03:13 Voltage Offset Correction: v_off_ini = 0.000000298 V, v_off_fin = -0.000003575 V 17:03:13 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142763129 Vs