SLAC Magnetic Measurements Date: 08-26-2020 Time: 16:18:02 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_008_Cell_38 Serial Number: HP_PC33408 Run Number: 7 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 7 16:18:04 Ambient Measurement Device(s) Being Used, type = None 16:18:04 Magnet Voltage Measurement Device(s) Being Used, type = None 16:18:05 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 16:18:05 XMAG Device(s) Being Used, type = None 16:18:05 Ambient Measurement Device(s) Being Used, type = None 16:18:28   Voltage Measurement, V = 0.000000 V 16:18:29 Temperature Measurement, Probe Number = 0, T = 22.090000 C 16:18:30 Temperature Measurement, Probe Number = 1, T = 22.623000 C 16:18:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.09 P2 = 3458_Meas_Junction, Value = 22.62 16:18:30 Integrated Voltage Measurement... 16:19:02 Voltage Offset Correction: v_off_ini = 0.000000012 V, v_off_fin = 0.000000625 V 16:19:02 Integrated Voltage Measurement Delta Gap = 0.0040023 m VT = 0.142903093 Vs 16:19:02 Integrated Voltage Measurement... 16:19:34 Voltage Offset Correction: v_off_ini = 0.000000372 V, v_off_fin = -0.000001565 V 16:19:34 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142808014 Vs 16:19:35   Voltage Measurement, V = 0.000000 V 16:19:35 Temperature Measurement, Probe Number = 0, T = 22.093000 C 16:19:36 Temperature Measurement, Probe Number = 1, T = 22.635000 C 16:19:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.09 P2 = 3458_Meas_Junction, Value = 22.64 16:19:36 Integrated Voltage Measurement... 16:20:12 Voltage Offset Correction: v_off_ini = -0.000000441 V, v_off_fin = 0.000001212 V 16:20:12 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142825309 Vs 16:20:12 Integrated Voltage Measurement... 16:21:03 Voltage Offset Correction: v_off_ini = 0.000000292 V, v_off_fin = -0.000001415 V 16:21:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142820871 Vs 16:21:04   Voltage Measurement, V = 0.000000 V 16:21:05 Temperature Measurement, Probe Number = 0, T = 22.126000 C 16:21:05 Temperature Measurement, Probe Number = 1, T = 22.638000 C 16:21:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.13 P2 = 3458_Meas_Junction, Value = 22.64 16:21:05 Integrated Voltage Measurement... 16:21:40 Voltage Offset Correction: v_off_ini = -0.000000587 V, v_off_fin = 0.000001534 V 16:21:40 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142828101 Vs 16:21:40 Integrated Voltage Measurement... 16:22:12 Voltage Offset Correction: v_off_ini = 0.000000224 V, v_off_fin = -0.000001694 V 16:22:12 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142808399 Vs 16:22:13   Voltage Measurement, V = 0.000000 V 16:22:14 Temperature Measurement, Probe Number = 0, T = 22.134000 C 16:22:15 Temperature Measurement, Probe Number = 1, T = 22.640000 C 16:22:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.13 P2 = 3458_Meas_Junction, Value = 22.64 16:22:15 Integrated Voltage Measurement... 16:22:48 Voltage Offset Correction: v_off_ini = -0.000000599 V, v_off_fin = 0.000001666 V 16:22:48 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142810890 Vs 16:22:48 Integrated Voltage Measurement... 16:23:44 Voltage Offset Correction: v_off_ini = 0.000000169 V, v_off_fin = -0.000001325 V 16:23:44 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142826477 Vs 16:23:45   Voltage Measurement, V = 0.000000 V 16:23:45 Temperature Measurement, Probe Number = 0, T = 22.147000 C 16:23:46 Temperature Measurement, Probe Number = 1, T = 22.637000 C 16:23:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.15 P2 = 3458_Meas_Junction, Value = 22.64 16:23:46 Integrated Voltage Measurement... 16:24:21 Voltage Offset Correction: v_off_ini = -0.000000501 V, v_off_fin = 0.000000668 V 16:24:21 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142819326 Vs 16:24:21 Integrated Voltage Measurement... 16:24:56 Voltage Offset Correction: v_off_ini = 0.000000519 V, v_off_fin = -0.000000833 V 16:24:56 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.142820257 Vs 16:24:57   Voltage Measurement, V = 0.000000 V 16:24:57 Temperature Measurement, Probe Number = 0, T = 22.135000 C 16:24:58 Temperature Measurement, Probe Number = 1, T = 22.652000 C 16:24:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.14 P2 = 3458_Meas_Junction, Value = 22.65 16:24:58 Integrated Voltage Measurement... 16:25:33 Voltage Offset Correction: v_off_ini = -0.000000596 V, v_off_fin = 0.000001680 V 16:25:33 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142829222 Vs 16:25:33 Integrated Voltage Measurement... 16:26:10 Voltage Offset Correction: v_off_ini = 0.000000509 V, v_off_fin = -0.000001671 V 16:26:10 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142818561 Vs 16:26:11   Voltage Measurement, V = 0.000000 V 16:26:12 Temperature Measurement, Probe Number = 0, T = 22.106000 C 16:26:12 Temperature Measurement, Probe Number = 1, T = 22.653000 C 16:26:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.11 P2 = 3458_Meas_Junction, Value = 22.65 16:26:12 Integrated Voltage Measurement... 16:26:45 Voltage Offset Correction: v_off_ini = -0.000000598 V, v_off_fin = 0.000001706 V 16:26:45 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142830113 Vs 16:26:45 Integrated Voltage Measurement... 16:27:17 Voltage Offset Correction: v_off_ini = 0.000000559 V, v_off_fin = -0.000001719 V 16:27:17 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142822207 Vs 16:27:18   Voltage Measurement, V = 0.000000 V 16:27:19 Temperature Measurement, Probe Number = 0, T = 22.078000 C 16:27:19 Temperature Measurement, Probe Number = 1, T = 22.649000 C 16:27:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.08 P2 = 3458_Meas_Junction, Value = 22.65 16:27:19 Integrated Voltage Measurement... 16:27:54 Voltage Offset Correction: v_off_ini = -0.000000655 V, v_off_fin = -0.000000670 V 16:27:54 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142821811 Vs 16:27:54 Integrated Voltage Measurement... 16:28:24 Voltage Offset Correction: v_off_ini = 0.000000376 V, v_off_fin = -0.000001981 V 16:28:24 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142823682 Vs 16:28:25   Voltage Measurement, V = 0.000000 V 16:28:25 Temperature Measurement, Probe Number = 0, T = 22.059000 C 16:28:26 Temperature Measurement, Probe Number = 1, T = 22.646000 C 16:28:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.06 P2 = 3458_Meas_Junction, Value = 22.65 16:28:26 Integrated Voltage Measurement... 16:28:59 Voltage Offset Correction: v_off_ini = -0.000000143 V, v_off_fin = 0.000001483 V 16:28:59 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142820348 Vs 16:28:59 Integrated Voltage Measurement... 16:29:31 Voltage Offset Correction: v_off_ini = 0.000000710 V, v_off_fin = -0.000002106 V 16:29:31 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142820647 Vs 16:29:32   Voltage Measurement, V = 0.000000 V 16:29:33 Temperature Measurement, Probe Number = 0, T = 22.045000 C 16:29:33 Temperature Measurement, Probe Number = 1, T = 22.661000 C 16:29:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.05 P2 = 3458_Meas_Junction, Value = 22.66 16:29:33 Integrated Voltage Measurement... 16:30:05 Voltage Offset Correction: v_off_ini = -0.000000780 V, v_off_fin = 0.000001053 V 16:30:05 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142830555 Vs 16:30:05 Integrated Voltage Measurement... 16:30:38 Voltage Offset Correction: v_off_ini = 0.000000530 V, v_off_fin = -0.000001905 V 16:30:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142824896 Vs