SLAC Magnetic Measurements Date: 01-20-2021 Time: 17:40:42 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_008_Cell_38 Serial Number: PC33408 Run Number: 16 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 16, no beam between 15 & 16 17:40:59 Ambient Measurement Device(s) Being Used, type = None 17:40:59 Magnet Voltage Measurement Device(s) Being Used, type = None 17:41:00 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 17:41:00 XMAG Device(s) Being Used, type = None 17:41:00 Ambient Measurement Device(s) Being Used, type = None 17:41:04   Voltage Measurement, V = 0.000000 V 17:41:05 Temperature Measurement, Probe Number = 0, T = 21.004000 C 17:41:06 Temperature Measurement, Probe Number = 1, T = 21.874000 C 17:41:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.00 P2 = 3458_Meas_Junction, Value = 21.87 17:41:06 Integrated Voltage Measurement... 17:41:32 Voltage Offset Correction: v_off_ini = 0.000001025 V, v_off_fin = 0.000001185 V 17:41:33 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = 0.142725170 Vs 17:41:33 Integrated Voltage Measurement... 17:42:03 Voltage Offset Correction: v_off_ini = 0.000001342 V, v_off_fin = -0.000000759 V 17:42:03 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142722918 Vs 17:42:04   Voltage Measurement, V = 0.000000 V 17:42:05 Temperature Measurement, Probe Number = 0, T = 21.037000 C 17:42:05 Temperature Measurement, Probe Number = 1, T = 21.912000 C 17:42:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.04 P2 = 3458_Meas_Junction, Value = 21.91 17:42:05 Integrated Voltage Measurement... 17:42:37 Voltage Offset Correction: v_off_ini = -0.000000390 V, v_off_fin = 0.000000885 V 17:42:37 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142761299 Vs 17:42:37 Integrated Voltage Measurement... 17:43:10 Voltage Offset Correction: v_off_ini = 0.000000565 V, v_off_fin = -0.000001611 V 17:43:10 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142714114 Vs 17:43:11   Voltage Measurement, V = 0.000000 V 17:43:12 Temperature Measurement, Probe Number = 0, T = 21.066000 C 17:43:12 Temperature Measurement, Probe Number = 1, T = 21.959000 C 17:43:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.07 P2 = 3458_Meas_Junction, Value = 21.96 17:43:12 Integrated Voltage Measurement... 17:43:44 Voltage Offset Correction: v_off_ini = -0.000000625 V, v_off_fin = 0.000000558 V 17:43:44 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142764963 Vs 17:43:44 Integrated Voltage Measurement... 17:44:15 Voltage Offset Correction: v_off_ini = 0.000000813 V, v_off_fin = -0.000001764 V 17:44:15 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142715912 Vs 17:44:16   Voltage Measurement, V = 0.000000 V 17:44:16 Temperature Measurement, Probe Number = 0, T = 21.058000 C 17:44:17 Temperature Measurement, Probe Number = 1, T = 21.962000 C 17:44:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.06 P2 = 3458_Meas_Junction, Value = 21.96 17:44:17 Integrated Voltage Measurement... 17:44:48 Voltage Offset Correction: v_off_ini = -0.000000470 V, v_off_fin = 0.000001416 V 17:44:48 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142751224 Vs 17:44:48 Integrated Voltage Measurement... 17:45:18 Voltage Offset Correction: v_off_ini = 0.000000746 V, v_off_fin = -0.000001940 V 17:45:18 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142719371 Vs 17:45:19   Voltage Measurement, V = 0.000000 V 17:45:20 Temperature Measurement, Probe Number = 0, T = 21.059000 C 17:45:20 Temperature Measurement, Probe Number = 1, T = 21.971000 C 17:45:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.06 P2 = 3458_Meas_Junction, Value = 21.97 17:45:20 Integrated Voltage Measurement... 17:45:51 Voltage Offset Correction: v_off_ini = -0.000000459 V, v_off_fin = 0.000002164 V 17:45:51 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142756555 Vs 17:45:51 Integrated Voltage Measurement... 17:46:22 Voltage Offset Correction: v_off_ini = 0.000000596 V, v_off_fin = -0.000001981 V 17:46:22 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142712256 Vs 17:46:23   Voltage Measurement, V = 0.000000 V 17:46:24 Temperature Measurement, Probe Number = 0, T = 21.083000 C 17:46:24 Temperature Measurement, Probe Number = 1, T = 21.977000 C 17:46:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.08 P2 = 3458_Meas_Junction, Value = 21.98 17:46:24 Integrated Voltage Measurement... 17:46:55 Voltage Offset Correction: v_off_ini = -0.000000512 V, v_off_fin = 0.000000246 V 17:46:55 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142751457 Vs 17:46:55 Integrated Voltage Measurement... 17:47:26 Voltage Offset Correction: v_off_ini = 0.000000797 V, v_off_fin = -0.000002162 V 17:47:26 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142714337 Vs 17:47:27   Voltage Measurement, V = 0.000000 V 17:47:28 Temperature Measurement, Probe Number = 0, T = 21.107000 C 17:47:28 Temperature Measurement, Probe Number = 1, T = 21.995000 C 17:47:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.11 P2 = 3458_Meas_Junction, Value = 22.00 17:47:28 Integrated Voltage Measurement... 17:48:00 Voltage Offset Correction: v_off_ini = -0.000000599 V, v_off_fin = 0.000001247 V 17:48:00 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142754534 Vs 17:48:00 Integrated Voltage Measurement... 17:48:34 Voltage Offset Correction: v_off_ini = 0.000000717 V, v_off_fin = -0.000001212 V 17:48:34 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142724169 Vs 17:48:35   Voltage Measurement, V = 0.000000 V 17:48:36 Temperature Measurement, Probe Number = 0, T = 21.153000 C 17:48:36 Temperature Measurement, Probe Number = 1, T = 21.988000 C 17:48:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.15 P2 = 3458_Meas_Junction, Value = 21.99 17:48:36 Integrated Voltage Measurement... 17:49:08 Voltage Offset Correction: v_off_ini = -0.000000841 V, v_off_fin = 0.000000380 V 17:49:08 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142765613 Vs 17:49:08 Integrated Voltage Measurement... 17:49:38 Voltage Offset Correction: v_off_ini = 0.000000628 V, v_off_fin = -0.000001815 V 17:49:38 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142722405 Vs 17:49:39   Voltage Measurement, V = 0.000000 V 17:49:40 Temperature Measurement, Probe Number = 0, T = 21.198000 C 17:49:40 Temperature Measurement, Probe Number = 1, T = 21.973000 C 17:49:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.20 P2 = 3458_Meas_Junction, Value = 21.97 17:49:40 Integrated Voltage Measurement... 17:50:11 Voltage Offset Correction: v_off_ini = -0.000000509 V, v_off_fin = 0.000000443 V 17:50:11 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142756761 Vs 17:50:11 Integrated Voltage Measurement... 17:50:41 Voltage Offset Correction: v_off_ini = 0.000000549 V, v_off_fin = -0.000001558 V 17:50:41 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142720858 Vs 17:50:42   Voltage Measurement, V = 0.000000 V 17:50:43 Temperature Measurement, Probe Number = 0, T = 21.205000 C 17:50:44 Temperature Measurement, Probe Number = 1, T = 21.997000 C 17:50:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.20 P2 = 3458_Meas_Junction, Value = 22.00 17:50:44 Integrated Voltage Measurement... 17:51:14 Voltage Offset Correction: v_off_ini = -0.000000555 V, v_off_fin = 0.000001569 V 17:51:14 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142763083 Vs 17:51:14 Integrated Voltage Measurement... 17:51:43 Voltage Offset Correction: v_off_ini = 0.000000658 V, v_off_fin = -0.000001858 V 17:51:43 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142722218 Vs