SLAC Magnetic Measurements Date: 01-07-2021 Time: 15:47:39 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_008_Cell_38 Serial Number: PC33408 Run Number: 15 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 15 15:47:56 Ambient Measurement Device(s) Being Used, type = None 15:47:56 Magnet Voltage Measurement Device(s) Being Used, type = None 15:47:57 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:47:57 XMAG Device(s) Being Used, type = None 15:47:57 Ambient Measurement Device(s) Being Used, type = None 15:47:58   Voltage Measurement, V = 0.000000 V 15:47:59 Temperature Measurement, Probe Number = 0, T = 20.930000 C 15:47:59 Temperature Measurement, Probe Number = 1, T = 21.833000 C 15:47:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.93 P2 = 3458_Meas_Junction, Value = 21.83 15:47:59 Integrated Voltage Measurement... 15:48:25 Voltage Offset Correction: v_off_ini = 0.000000892 V, v_off_fin = 0.000001380 V 15:48:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142878858 Vs 15:48:25 Integrated Voltage Measurement... 15:48:58 Voltage Offset Correction: v_off_ini = 0.000001394 V, v_off_fin = -0.000001769 V 15:48:58 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142827595 Vs 15:48:59   Voltage Measurement, V = 0.000000 V 15:49:00 Temperature Measurement, Probe Number = 0, T = 20.915000 C 15:49:00 Temperature Measurement, Probe Number = 1, T = 21.844000 C 15:49:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.91 P2 = 3458_Meas_Junction, Value = 21.84 15:49:00 Integrated Voltage Measurement... 15:49:40 Voltage Offset Correction: v_off_ini = 0.000000049 V, v_off_fin = 0.000001602 V 15:49:40 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142857922 Vs 15:49:40 Integrated Voltage Measurement... 15:50:18 Voltage Offset Correction: v_off_ini = 0.000000576 V, v_off_fin = -0.000001363 V 15:50:18 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142833997 Vs 15:50:19   Voltage Measurement, V = 0.000000 V 15:50:19 Temperature Measurement, Probe Number = 0, T = 20.909000 C 15:50:20 Temperature Measurement, Probe Number = 1, T = 21.889000 C 15:50:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.91 P2 = 3458_Meas_Junction, Value = 21.89 15:50:20 Integrated Voltage Measurement... 15:50:50 Voltage Offset Correction: v_off_ini = -0.000000911 V, v_off_fin = 0.000000614 V 15:50:50 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142866742 Vs 15:50:50 Integrated Voltage Measurement... 15:51:21 Voltage Offset Correction: v_off_ini = 0.000000660 V, v_off_fin = -0.000002051 V 15:51:21 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142831623 Vs 15:51:22   Voltage Measurement, V = 0.000000 V 15:51:23 Temperature Measurement, Probe Number = 0, T = 20.908000 C 15:51:23 Temperature Measurement, Probe Number = 1, T = 21.898000 C 15:51:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.91 P2 = 3458_Meas_Junction, Value = 21.90 15:51:23 Integrated Voltage Measurement... 15:52:00 Voltage Offset Correction: v_off_ini = -0.000000569 V, v_off_fin = 0.000002078 V 15:52:00 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142868209 Vs 15:52:00 Integrated Voltage Measurement... 15:52:32 Voltage Offset Correction: v_off_ini = 0.000000559 V, v_off_fin = -0.000001544 V 15:52:32 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142823731 Vs 15:52:33   Voltage Measurement, V = 0.000000 V 15:52:33 Temperature Measurement, Probe Number = 0, T = 20.905000 C 15:52:34 Temperature Measurement, Probe Number = 1, T = 21.894000 C 15:52:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.91 P2 = 3458_Meas_Junction, Value = 21.89 15:52:34 Integrated Voltage Measurement... 15:53:04 Voltage Offset Correction: v_off_ini = -0.000000601 V, v_off_fin = 0.000000874 V 15:53:04 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.142853232 Vs 15:53:04 Integrated Voltage Measurement... 15:53:35 Voltage Offset Correction: v_off_ini = 0.000000698 V, v_off_fin = -0.000001478 V 15:53:35 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142825370 Vs 15:53:36   Voltage Measurement, V = 0.000000 V 15:53:37 Temperature Measurement, Probe Number = 0, T = 20.897000 C 15:53:38 Temperature Measurement, Probe Number = 1, T = 21.913000 C 15:53:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.90 P2 = 3458_Meas_Junction, Value = 21.91 15:53:38 Integrated Voltage Measurement... 15:54:09 Voltage Offset Correction: v_off_ini = -0.000000693 V, v_off_fin = 0.000001081 V 15:54:09 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142862604 Vs 15:54:09 Integrated Voltage Measurement... 15:54:39 Voltage Offset Correction: v_off_ini = 0.000000385 V, v_off_fin = -0.000002512 V 15:54:39 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142828940 Vs 15:54:40   Voltage Measurement, V = 0.000000 V 15:54:40 Temperature Measurement, Probe Number = 0, T = 20.899000 C 15:54:41 Temperature Measurement, Probe Number = 1, T = 21.914000 C 15:54:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.90 P2 = 3458_Meas_Junction, Value = 21.91 15:54:41 Integrated Voltage Measurement... 15:55:12 Voltage Offset Correction: v_off_ini = -0.000000766 V, v_off_fin = 0.000000592 V 15:55:12 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142868515 Vs 15:55:12 Integrated Voltage Measurement... 15:55:42 Voltage Offset Correction: v_off_ini = 0.000000586 V, v_off_fin = -0.000001692 V 15:55:42 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142826040 Vs 15:55:43   Voltage Measurement, V = 0.000000 V 15:55:44 Temperature Measurement, Probe Number = 0, T = 20.911000 C 15:55:44 Temperature Measurement, Probe Number = 1, T = 21.950000 C 15:55:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.91 P2 = 3458_Meas_Junction, Value = 21.95 15:55:44 Integrated Voltage Measurement... 15:56:15 Voltage Offset Correction: v_off_ini = -0.000000752 V, v_off_fin = 0.000000836 V 15:56:15 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142853746 Vs 15:56:15 Integrated Voltage Measurement... 15:56:45 Voltage Offset Correction: v_off_ini = 0.000000383 V, v_off_fin = -0.000000249 V 15:56:45 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142825531 Vs 15:56:46   Voltage Measurement, V = 0.000000 V 15:56:47 Temperature Measurement, Probe Number = 0, T = 20.920000 C 15:56:47 Temperature Measurement, Probe Number = 1, T = 21.973000 C 15:56:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.92 P2 = 3458_Meas_Junction, Value = 21.97 15:56:48 Integrated Voltage Measurement... 15:57:18 Voltage Offset Correction: v_off_ini = -0.000000795 V, v_off_fin = 0.000000803 V 15:57:18 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142857875 Vs 15:57:18 Integrated Voltage Measurement... 15:57:50 Voltage Offset Correction: v_off_ini = 0.000000492 V, v_off_fin = -0.000001442 V 15:57:50 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142834216 Vs 15:57:51   Voltage Measurement, V = 0.000000 V 15:57:51 Temperature Measurement, Probe Number = 0, T = 20.924000 C 15:57:52 Temperature Measurement, Probe Number = 1, T = 21.998000 C 15:57:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.92 P2 = 3458_Meas_Junction, Value = 22.00 15:57:52 Integrated Voltage Measurement... 15:58:25 Voltage Offset Correction: v_off_ini = -0.000000631 V, v_off_fin = 0.000000709 V 15:58:25 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142856972 Vs 15:58:25 Integrated Voltage Measurement... 15:59:01 Voltage Offset Correction: v_off_ini = 0.000000480 V, v_off_fin = -0.000001373 V 15:59:02 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142824041 Vs