SLAC Magnetic Measurements Date: 10-06-2020 Time: 16:18:54 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_008_Cell_38 Serial Number: PC33408 Run Number: 10 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 10 16:18:56 Ambient Measurement Device(s) Being Used, type = None 16:18:56 Magnet Voltage Measurement Device(s) Being Used, type = None 16:18:57 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 16:18:57 XMAG Device(s) Being Used, type = None 16:18:57 Ambient Measurement Device(s) Being Used, type = None 16:19:04   Voltage Measurement, V = 0.000000 V 16:19:05 Temperature Measurement, Probe Number = 0, T = 21.266000 C 16:19:05 Temperature Measurement, Probe Number = 1, T = 21.367000 C 16:19:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.27 P2 = 3458_Meas_Junction, Value = 21.37 16:19:05 Integrated Voltage Measurement... 16:19:34 Voltage Offset Correction: v_off_ini = -0.000000806 V, v_off_fin = 0.000000790 V 16:19:34 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142923226 Vs 16:19:34 Integrated Voltage Measurement... 16:20:07 Voltage Offset Correction: v_off_ini = 0.000000018 V, v_off_fin = -0.000002465 V 16:20:07 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142870272 Vs 16:20:08   Voltage Measurement, V = 0.000000 V 16:20:08 Temperature Measurement, Probe Number = 0, T = 21.245000 C 16:20:09 Temperature Measurement, Probe Number = 1, T = 21.367000 C 16:20:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.25 P2 = 3458_Meas_Junction, Value = 21.37 16:20:09 Integrated Voltage Measurement... 16:20:39 Voltage Offset Correction: v_off_ini = -0.000001719 V, v_off_fin = -0.000000166 V 16:20:39 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142906936 Vs 16:20:39 Integrated Voltage Measurement... 16:21:10 Voltage Offset Correction: v_off_ini = -0.000000268 V, v_off_fin = -0.000002751 V 16:21:10 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142868629 Vs 16:21:11   Voltage Measurement, V = 0.000000 V 16:21:12 Temperature Measurement, Probe Number = 0, T = 21.234000 C 16:21:12 Temperature Measurement, Probe Number = 1, T = 21.360000 C 16:21:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.23 P2 = 3458_Meas_Junction, Value = 21.36 16:21:12 Integrated Voltage Measurement... 16:21:43 Voltage Offset Correction: v_off_ini = -0.000001595 V, v_off_fin = -0.000000430 V 16:21:43 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142909354 Vs 16:21:43 Integrated Voltage Measurement... 16:22:27 Voltage Offset Correction: v_off_ini = -0.000000356 V, v_off_fin = -0.000003560 V 16:22:27 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142877091 Vs 16:22:28   Voltage Measurement, V = 0.000000 V 16:22:29 Temperature Measurement, Probe Number = 0, T = 21.284000 C 16:22:30 Temperature Measurement, Probe Number = 1, T = 21.377000 C 16:22:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.28 P2 = 3458_Meas_Junction, Value = 21.38 16:22:30 Integrated Voltage Measurement... 16:23:03 Voltage Offset Correction: v_off_ini = -0.000001639 V, v_off_fin = -0.000000259 V 16:23:03 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.142914990 Vs 16:23:03 Integrated Voltage Measurement... 16:23:34 Voltage Offset Correction: v_off_ini = -0.000000180 V, v_off_fin = -0.000003082 V 16:23:34 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142880102 Vs 16:23:35   Voltage Measurement, V = 0.000000 V 16:23:35 Temperature Measurement, Probe Number = 0, T = 21.301000 C 16:23:36 Temperature Measurement, Probe Number = 1, T = 21.400000 C 16:23:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.30 P2 = 3458_Meas_Junction, Value = 21.40 16:23:36 Integrated Voltage Measurement... 16:24:07 Voltage Offset Correction: v_off_ini = -0.000001616 V, v_off_fin = 0.000000224 V 16:24:07 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142920037 Vs 16:24:07 Integrated Voltage Measurement... 16:24:43 Voltage Offset Correction: v_off_ini = -0.000000295 V, v_off_fin = -0.000001944 V 16:24:43 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142881446 Vs 16:24:44   Voltage Measurement, V = 0.000000 V 16:24:44 Temperature Measurement, Probe Number = 0, T = 21.294000 C 16:24:45 Temperature Measurement, Probe Number = 1, T = 21.413000 C 16:24:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.29 P2 = 3458_Meas_Junction, Value = 21.41 16:24:45 Integrated Voltage Measurement... 16:25:17 Voltage Offset Correction: v_off_ini = -0.000001300 V, v_off_fin = -0.000000110 V 16:25:17 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142914292 Vs 16:25:17 Integrated Voltage Measurement... 16:25:49 Voltage Offset Correction: v_off_ini = -0.000000283 V, v_off_fin = -0.000003037 V 16:25:49 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142881758 Vs 16:25:50   Voltage Measurement, V = 0.000000 V 16:25:50 Temperature Measurement, Probe Number = 0, T = 21.282000 C 16:25:51 Temperature Measurement, Probe Number = 1, T = 21.415000 C 16:25:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.28 P2 = 3458_Meas_Junction, Value = 21.41 16:25:51 Integrated Voltage Measurement... 16:26:22 Voltage Offset Correction: v_off_ini = -0.000001473 V, v_off_fin = 0.000000742 V 16:26:22 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142915065 Vs 16:26:22 Integrated Voltage Measurement... 16:26:57 Voltage Offset Correction: v_off_ini = -0.000000330 V, v_off_fin = -0.000003216 V 16:26:57 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142877205 Vs 16:26:58   Voltage Measurement, V = 0.000000 V 16:26:58 Temperature Measurement, Probe Number = 0, T = 21.261000 C 16:26:59 Temperature Measurement, Probe Number = 1, T = 21.427000 C 16:26:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.26 P2 = 3458_Meas_Junction, Value = 21.43 16:26:59 Integrated Voltage Measurement... 16:27:31 Voltage Offset Correction: v_off_ini = -0.000001509 V, v_off_fin = -0.000000071 V 16:27:31 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142908518 Vs 16:27:31 Integrated Voltage Measurement... 16:28:02 Voltage Offset Correction: v_off_ini = -0.000000102 V, v_off_fin = -0.000002070 V 16:28:02 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142875382 Vs 16:28:03   Voltage Measurement, V = 0.000000 V 16:28:04 Temperature Measurement, Probe Number = 0, T = 21.236000 C 16:28:04 Temperature Measurement, Probe Number = 1, T = 21.424000 C 16:28:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.24 P2 = 3458_Meas_Junction, Value = 21.42 16:28:04 Integrated Voltage Measurement... 16:28:47 Voltage Offset Correction: v_off_ini = -0.000001186 V, v_off_fin = -0.000000180 V 16:28:47 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142911136 Vs 16:28:47 Integrated Voltage Measurement... 16:29:23 Voltage Offset Correction: v_off_ini = -0.000000149 V, v_off_fin = -0.000002471 V 16:29:23 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142877813 Vs 16:29:24   Voltage Measurement, V = 0.000000 V 16:29:25 Temperature Measurement, Probe Number = 0, T = 21.213000 C 16:29:25 Temperature Measurement, Probe Number = 1, T = 21.431000 C 16:29:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.21 P2 = 3458_Meas_Junction, Value = 21.43 16:29:25 Integrated Voltage Measurement... 16:30:05 Voltage Offset Correction: v_off_ini = -0.000001203 V, v_off_fin = -0.000000036 V 16:30:05 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.142916272 Vs 16:30:05 Integrated Voltage Measurement... 16:30:38 Voltage Offset Correction: v_off_ini = -0.000000059 V, v_off_fin = -0.000002631 V 16:30:38 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142874081 Vs