SLAC Magnetic Measurements Date: 11-17-2020 Time: 17:33:47 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_007_Cell_33_Upstairs Serial Number: PC33408 Run Number: 7 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement upstairs, cable straight into 3458. Full Set 6 17:34:05 Ambient Measurement Device(s) Being Used, type = None 17:34:05 Magnet Voltage Measurement Device(s) Being Used, type = None 17:34:05 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 17:34:05 XMAG Device(s) Being Used, type = None 17:34:05 Ambient Measurement Device(s) Being Used, type = None 17:34:15   Voltage Measurement, V = 0.000000 V 17:34:16 Temperature Measurement, Probe Number = 0, T = 23.649000 C 17:34:16 Temperature Measurement, Probe Number = 1, T = 24.839000 C 17:34:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.65 P2 = 3458_Meas_Junction, Value = 24.84 17:34:16 Integrated Voltage Measurement... 17:34:42 Voltage Offset Correction: v_off_ini = 0.000003185 V, v_off_fin = 0.000003739 V 17:34:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143084674 Vs 17:34:42 Integrated Voltage Measurement... 17:35:18 Voltage Offset Correction: v_off_ini = 0.000003833 V, v_off_fin = 0.000001861 V 17:35:18 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143049651 Vs 17:35:19   Voltage Measurement, V = 0.000000 V 17:35:20 Temperature Measurement, Probe Number = 0, T = 23.624000 C 17:35:20 Temperature Measurement, Probe Number = 1, T = 24.773000 C 17:35:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.62 P2 = 3458_Meas_Junction, Value = 24.77 17:35:20 Integrated Voltage Measurement... 17:35:54 Voltage Offset Correction: v_off_ini = 0.000002643 V, v_off_fin = 0.000002760 V 17:35:54 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143070175 Vs 17:35:54 Integrated Voltage Measurement... 17:36:25 Voltage Offset Correction: v_off_ini = 0.000003416 V, v_off_fin = 0.000001685 V 17:36:26 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143050683 Vs 17:36:27   Voltage Measurement, V = 0.000000 V 17:36:27 Temperature Measurement, Probe Number = 0, T = 23.610000 C 17:36:28 Temperature Measurement, Probe Number = 1, T = 24.731000 C 17:36:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.61 P2 = 3458_Meas_Junction, Value = 24.73 17:36:28 Integrated Voltage Measurement... 17:37:08 Voltage Offset Correction: v_off_ini = 0.000002756 V, v_off_fin = 0.000003144 V 17:37:08 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143074991 Vs 17:37:08 Integrated Voltage Measurement... 17:37:38 Voltage Offset Correction: v_off_ini = 0.000003247 V, v_off_fin = 0.000001785 V 17:37:38 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143056832 Vs 17:37:39   Voltage Measurement, V = 0.000000 V 17:37:40 Temperature Measurement, Probe Number = 0, T = 23.590000 C 17:37:40 Temperature Measurement, Probe Number = 1, T = 24.712000 C 17:37:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.59 P2 = 3458_Meas_Junction, Value = 24.71 17:37:40 Integrated Voltage Measurement... 17:38:13 Voltage Offset Correction: v_off_ini = 0.000002561 V, v_off_fin = 0.000005216 V 17:38:13 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143086237 Vs 17:38:13 Integrated Voltage Measurement... 17:39:04 Voltage Offset Correction: v_off_ini = 0.000003173 V, v_off_fin = 0.000000983 V 17:39:04 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143047457 Vs 17:39:05   Voltage Measurement, V = 0.000000 V 17:39:06 Temperature Measurement, Probe Number = 0, T = 23.588000 C 17:39:06 Temperature Measurement, Probe Number = 1, T = 24.676000 C 17:39:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.59 P2 = 3458_Meas_Junction, Value = 24.68 17:39:06 Integrated Voltage Measurement... 17:39:38 Voltage Offset Correction: v_off_ini = 0.000002344 V, v_off_fin = 0.000003064 V 17:39:38 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143076247 Vs 17:39:38 Integrated Voltage Measurement... 17:40:14 Voltage Offset Correction: v_off_ini = 0.000003492 V, v_off_fin = 0.000001602 V 17:40:14 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143041898 Vs 17:40:15   Voltage Measurement, V = 0.000000 V 17:40:15 Temperature Measurement, Probe Number = 0, T = 23.571000 C 17:40:16 Temperature Measurement, Probe Number = 1, T = 24.652000 C 17:40:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.57 P2 = 3458_Meas_Junction, Value = 24.65 17:40:16 Integrated Voltage Measurement... 17:40:47 Voltage Offset Correction: v_off_ini = 0.000002442 V, v_off_fin = 0.000003340 V 17:40:47 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143074492 Vs 17:40:47 Integrated Voltage Measurement... 17:41:23 Voltage Offset Correction: v_off_ini = 0.000003291 V, v_off_fin = 0.000002362 V 17:41:23 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143047463 Vs 17:41:24   Voltage Measurement, V = 0.000000 V 17:41:25 Temperature Measurement, Probe Number = 0, T = 23.546000 C 17:41:26 Temperature Measurement, Probe Number = 1, T = 24.632000 C 17:41:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.55 P2 = 3458_Meas_Junction, Value = 24.63 17:41:26 Integrated Voltage Measurement... 17:42:04 Voltage Offset Correction: v_off_ini = 0.000002325 V, v_off_fin = 0.000003302 V 17:42:04 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143075980 Vs 17:42:04 Integrated Voltage Measurement... 17:42:40 Voltage Offset Correction: v_off_ini = 0.000003406 V, v_off_fin = 0.000002159 V 17:42:40 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143047040 Vs 17:42:41   Voltage Measurement, V = 0.000000 V 17:42:41 Temperature Measurement, Probe Number = 0, T = 23.524000 C 17:42:42 Temperature Measurement, Probe Number = 1, T = 24.630000 C 17:42:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.52 P2 = 3458_Meas_Junction, Value = 24.63 17:42:42 Integrated Voltage Measurement... 17:43:13 Voltage Offset Correction: v_off_ini = 0.000002712 V, v_off_fin = 0.000003603 V 17:43:13 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.143072166 Vs 17:43:13 Integrated Voltage Measurement... 17:43:54 Voltage Offset Correction: v_off_ini = 0.000003368 V, v_off_fin = 0.000001934 V 17:43:54 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143051378 Vs 17:43:55   Voltage Measurement, V = 0.000000 V 17:43:55 Temperature Measurement, Probe Number = 0, T = 23.504000 C 17:43:56 Temperature Measurement, Probe Number = 1, T = 24.597000 C 17:43:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.50 P2 = 3458_Meas_Junction, Value = 24.60 17:43:56 Integrated Voltage Measurement... 17:44:29 Voltage Offset Correction: v_off_ini = 0.000002474 V, v_off_fin = 0.000003379 V 17:44:29 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.143067204 Vs 17:44:29 Integrated Voltage Measurement... 17:45:05 Voltage Offset Correction: v_off_ini = 0.000003423 V, v_off_fin = 0.000002207 V 17:45:05 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.143052987 Vs 17:45:06   Voltage Measurement, V = 0.000000 V 17:45:07 Temperature Measurement, Probe Number = 0, T = 23.488000 C 17:45:07 Temperature Measurement, Probe Number = 1, T = 24.593000 C 17:45:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.49 P2 = 3458_Meas_Junction, Value = 24.59 17:45:07 Integrated Voltage Measurement... 17:45:42 Voltage Offset Correction: v_off_ini = 0.000002281 V, v_off_fin = 0.000003415 V 17:45:42 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143084476 Vs 17:45:42 Integrated Voltage Measurement... 17:46:15 Voltage Offset Correction: v_off_ini = 0.000003359 V, v_off_fin = 0.000001528 V 17:46:15 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143049239 Vs