SLAC Magnetic Measurements Date: 01-07-2021 Time: 12:35:39 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_007_Cell_33 Serial Number: PC33408 Run Number: 15 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 15 12:35:57 Ambient Measurement Device(s) Being Used, type = None 12:35:57 Magnet Voltage Measurement Device(s) Being Used, type = None 12:35:57 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 12:35:57 XMAG Device(s) Being Used, type = None 12:35:57 Ambient Measurement Device(s) Being Used, type = None 12:36:00   Voltage Measurement, V = 0.000000 V 12:36:00 Temperature Measurement, Probe Number = 0, T = 20.605000 C 12:36:01 Temperature Measurement, Probe Number = 1, T = 21.626000 C 12:36:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.61 P2 = 3458_Meas_Junction, Value = 21.63 12:36:01 Integrated Voltage Measurement... 12:36:27 Voltage Offset Correction: v_off_ini = 0.000000434 V, v_off_fin = 0.000001873 V 12:36:27 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143288191 Vs 12:36:27 Integrated Voltage Measurement... 12:36:58 Voltage Offset Correction: v_off_ini = 0.000000615 V, v_off_fin = -0.000001502 V 12:36:58 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143285737 Vs 12:36:59   Voltage Measurement, V = 0.000000 V 12:37:00 Temperature Measurement, Probe Number = 0, T = 20.597000 C 12:37:01 Temperature Measurement, Probe Number = 1, T = 21.627000 C 12:37:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.60 P2 = 3458_Meas_Junction, Value = 21.63 12:37:01 Integrated Voltage Measurement... 12:37:36 Voltage Offset Correction: v_off_ini = -0.000000337 V, v_off_fin = 0.000001057 V 12:37:36 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143304503 Vs 12:37:36 Integrated Voltage Measurement... 12:38:08 Voltage Offset Correction: v_off_ini = 0.000000405 V, v_off_fin = -0.000001554 V 12:38:08 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143275800 Vs 12:38:09   Voltage Measurement, V = 0.000000 V 12:38:10 Temperature Measurement, Probe Number = 0, T = 20.616000 C 12:38:10 Temperature Measurement, Probe Number = 1, T = 21.631000 C 12:38:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.62 P2 = 3458_Meas_Junction, Value = 21.63 12:38:10 Integrated Voltage Measurement... 12:38:41 Voltage Offset Correction: v_off_ini = -0.000000520 V, v_off_fin = 0.000000797 V 12:38:41 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143290774 Vs 12:38:42 Integrated Voltage Measurement... 12:39:12 Voltage Offset Correction: v_off_ini = 0.000000437 V, v_off_fin = -0.000000516 V 12:39:12 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.143270879 Vs 12:39:13   Voltage Measurement, V = 0.000000 V 12:39:13 Temperature Measurement, Probe Number = 0, T = 20.622000 C 12:39:14 Temperature Measurement, Probe Number = 1, T = 21.643000 C 12:39:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.62 P2 = 3458_Meas_Junction, Value = 21.64 12:39:14 Integrated Voltage Measurement... 12:39:45 Voltage Offset Correction: v_off_ini = -0.000000536 V, v_off_fin = 0.000001241 V 12:39:45 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.143293232 Vs 12:39:45 Integrated Voltage Measurement... 12:40:15 Voltage Offset Correction: v_off_ini = 0.000000419 V, v_off_fin = -0.000001762 V 12:40:15 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143269132 Vs 12:40:16   Voltage Measurement, V = 0.000000 V 12:40:17 Temperature Measurement, Probe Number = 0, T = 20.631000 C 12:40:18 Temperature Measurement, Probe Number = 1, T = 21.656000 C 12:40:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.63 P2 = 3458_Meas_Junction, Value = 21.66 12:40:18 Integrated Voltage Measurement... 12:40:49 Voltage Offset Correction: v_off_ini = -0.000000692 V, v_off_fin = 0.000000315 V 12:40:49 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143302243 Vs 12:40:49 Integrated Voltage Measurement... 12:41:19 Voltage Offset Correction: v_off_ini = 0.000000418 V, v_off_fin = -0.000001757 V 12:41:19 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143275891 Vs 12:41:20   Voltage Measurement, V = 0.000000 V 12:41:20 Temperature Measurement, Probe Number = 0, T = 20.631000 C 12:41:21 Temperature Measurement, Probe Number = 1, T = 21.675000 C 12:41:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.63 P2 = 3458_Meas_Junction, Value = 21.68 12:41:21 Integrated Voltage Measurement... 12:41:52 Voltage Offset Correction: v_off_ini = -0.000000492 V, v_off_fin = 0.000000854 V 12:41:52 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143304452 Vs 12:41:52 Integrated Voltage Measurement... 12:42:22 Voltage Offset Correction: v_off_ini = 0.000000341 V, v_off_fin = -0.000001440 V 12:42:22 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143269898 Vs 12:42:23   Voltage Measurement, V = 0.000000 V 12:42:24 Temperature Measurement, Probe Number = 0, T = 20.625000 C 12:42:25 Temperature Measurement, Probe Number = 1, T = 21.670000 C 12:42:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.62 P2 = 3458_Meas_Junction, Value = 21.67 12:42:25 Integrated Voltage Measurement... 12:42:56 Voltage Offset Correction: v_off_ini = -0.000000670 V, v_off_fin = 0.000001463 V 12:42:56 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143307094 Vs 12:42:56 Integrated Voltage Measurement... 12:43:26 Voltage Offset Correction: v_off_ini = 0.000000498 V, v_off_fin = -0.000001688 V 12:43:26 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143267267 Vs 12:43:27   Voltage Measurement, V = 0.000000 V 12:43:28 Temperature Measurement, Probe Number = 0, T = 20.620000 C 12:43:28 Temperature Measurement, Probe Number = 1, T = 21.670000 C 12:43:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.62 P2 = 3458_Meas_Junction, Value = 21.67 12:43:28 Integrated Voltage Measurement... 12:44:02 Voltage Offset Correction: v_off_ini = -0.000000595 V, v_off_fin = 0.000000609 V 12:44:02 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143296477 Vs 12:44:02 Integrated Voltage Measurement... 12:44:34 Voltage Offset Correction: v_off_ini = 0.000000267 V, v_off_fin = -0.000001498 V 12:44:34 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143275157 Vs 12:44:35   Voltage Measurement, V = 0.000000 V 12:44:36 Temperature Measurement, Probe Number = 0, T = 20.611000 C 12:44:36 Temperature Measurement, Probe Number = 1, T = 21.675000 C 12:44:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.61 P2 = 3458_Meas_Junction, Value = 21.68 12:44:36 Integrated Voltage Measurement... 12:45:07 Voltage Offset Correction: v_off_ini = -0.000000968 V, v_off_fin = 0.000000651 V 12:45:07 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143296125 Vs 12:45:07 Integrated Voltage Measurement... 12:45:38 Voltage Offset Correction: v_off_ini = 0.000000414 V, v_off_fin = -0.000001183 V 12:45:38 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.143276152 Vs 12:45:39   Voltage Measurement, V = 0.000000 V 12:45:40 Temperature Measurement, Probe Number = 0, T = 20.609000 C 12:45:40 Temperature Measurement, Probe Number = 1, T = 21.675000 C 12:45:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.61 P2 = 3458_Meas_Junction, Value = 21.68 12:45:40 Integrated Voltage Measurement... 12:46:11 Voltage Offset Correction: v_off_ini = -0.000000759 V, v_off_fin = 0.000000453 V 12:46:11 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143302237 Vs 12:46:11 Integrated Voltage Measurement... 12:46:41 Voltage Offset Correction: v_off_ini = 0.000000456 V, v_off_fin = -0.000000413 V 12:46:41 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143274778 Vs