SLAC Magnetic Measurements Date: 11-18-2020 Time: 13:42:33 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_007_Cell_33 Serial Number: PC33408 Run Number: 13 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 13 13:42:50 Ambient Measurement Device(s) Being Used, type = None 13:42:50 Magnet Voltage Measurement Device(s) Being Used, type = None 13:42:51 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 13:42:51 XMAG Device(s) Being Used, type = None 13:42:51 Ambient Measurement Device(s) Being Used, type = None 13:42:53   Voltage Measurement, V = 0.000000 V 13:42:54 Temperature Measurement, Probe Number = 0, T = 20.988000 C 13:42:55 Temperature Measurement, Probe Number = 1, T = 21.464000 C 13:42:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.99 P2 = 3458_Meas_Junction, Value = 21.46 13:42:55 Integrated Voltage Measurement... 13:43:21 Voltage Offset Correction: v_off_ini = -0.000000701 V, v_off_fin = -0.000000492 V 13:43:21 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143109510 Vs 13:43:21 Integrated Voltage Measurement... 13:43:53 Voltage Offset Correction: v_off_ini = -0.000000623 V, v_off_fin = -0.000002989 V 13:43:53 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143058070 Vs 13:43:54   Voltage Measurement, V = 0.000000 V 13:43:55 Temperature Measurement, Probe Number = 0, T = 20.965000 C 13:43:55 Temperature Measurement, Probe Number = 1, T = 21.477000 C 13:43:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.96 P2 = 3458_Meas_Junction, Value = 21.48 13:43:55 Integrated Voltage Measurement... 13:44:28 Voltage Offset Correction: v_off_ini = -0.000001397 V, v_off_fin = -0.000000360 V 13:44:28 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143090379 Vs 13:44:28 Integrated Voltage Measurement... 13:44:59 Voltage Offset Correction: v_off_ini = -0.000000696 V, v_off_fin = -0.000002379 V 13:44:59 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143068777 Vs 13:45:00   Voltage Measurement, V = 0.000000 V 13:45:01 Temperature Measurement, Probe Number = 0, T = 20.951000 C 13:45:02 Temperature Measurement, Probe Number = 1, T = 21.481000 C 13:45:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.95 P2 = 3458_Meas_Junction, Value = 21.48 13:45:02 Integrated Voltage Measurement... 13:45:32 Voltage Offset Correction: v_off_ini = -0.000001935 V, v_off_fin = -0.000002589 V 13:45:32 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143095335 Vs 13:45:32 Integrated Voltage Measurement... 13:46:05 Voltage Offset Correction: v_off_ini = -0.000001160 V, v_off_fin = -0.000002460 V 13:46:05 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143071762 Vs 13:46:06   Voltage Measurement, V = 0.000000 V 13:46:07 Temperature Measurement, Probe Number = 0, T = 20.934000 C 13:46:07 Temperature Measurement, Probe Number = 1, T = 21.484000 C 13:46:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.93 P2 = 3458_Meas_Junction, Value = 21.48 13:46:07 Integrated Voltage Measurement... 13:46:39 Voltage Offset Correction: v_off_ini = -0.000001880 V, v_off_fin = -0.000000019 V 13:46:39 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143093980 Vs 13:46:39 Integrated Voltage Measurement... 13:47:10 Voltage Offset Correction: v_off_ini = -0.000000892 V, v_off_fin = -0.000003232 V 13:47:10 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143072953 Vs 13:47:11   Voltage Measurement, V = 0.000000 V 13:47:12 Temperature Measurement, Probe Number = 0, T = 20.934000 C 13:47:13 Temperature Measurement, Probe Number = 1, T = 21.477000 C 13:47:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.93 P2 = 3458_Meas_Junction, Value = 21.48 13:47:13 Integrated Voltage Measurement... 13:47:44 Voltage Offset Correction: v_off_ini = -0.000002375 V, v_off_fin = -0.000000708 V 13:47:44 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143107129 Vs 13:47:44 Integrated Voltage Measurement... 13:48:14 Voltage Offset Correction: v_off_ini = -0.000000740 V, v_off_fin = -0.000003496 V 13:48:14 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143072978 Vs 13:48:15   Voltage Measurement, V = 0.000000 V 13:48:16 Temperature Measurement, Probe Number = 0, T = 20.934000 C 13:48:17 Temperature Measurement, Probe Number = 1, T = 21.468000 C 13:48:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.93 P2 = 3458_Meas_Junction, Value = 21.47 13:48:17 Integrated Voltage Measurement... 13:48:49 Voltage Offset Correction: v_off_ini = -0.000002382 V, v_off_fin = -0.000000829 V 13:48:49 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143112855 Vs 13:48:49 Integrated Voltage Measurement... 13:49:20 Voltage Offset Correction: v_off_ini = -0.000000773 V, v_off_fin = -0.000002023 V 13:49:20 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143069041 Vs 13:49:21   Voltage Measurement, V = 0.000000 V 13:49:21 Temperature Measurement, Probe Number = 0, T = 20.928000 C 13:49:22 Temperature Measurement, Probe Number = 1, T = 21.468000 C 13:49:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.93 P2 = 3458_Meas_Junction, Value = 21.47 13:49:22 Integrated Voltage Measurement... 13:49:59 Voltage Offset Correction: v_off_ini = -0.000001739 V, v_off_fin = -0.000000821 V 13:49:59 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143105339 Vs 13:49:59 Integrated Voltage Measurement... 13:50:29 Voltage Offset Correction: v_off_ini = -0.000001042 V, v_off_fin = -0.000003333 V 13:50:29 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143065448 Vs 13:50:30   Voltage Measurement, V = 0.000000 V 13:50:31 Temperature Measurement, Probe Number = 0, T = 20.913000 C 13:50:31 Temperature Measurement, Probe Number = 1, T = 21.470000 C 13:50:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.91 P2 = 3458_Meas_Junction, Value = 21.47 13:50:31 Integrated Voltage Measurement... 13:51:03 Voltage Offset Correction: v_off_ini = -0.000002073 V, v_off_fin = -0.000000455 V 13:51:03 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143091447 Vs 13:51:03 Integrated Voltage Measurement... 13:51:36 Voltage Offset Correction: v_off_ini = -0.000000864 V, v_off_fin = -0.000003468 V 13:51:36 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143070521 Vs 13:51:37   Voltage Measurement, V = 0.000000 V 13:51:38 Temperature Measurement, Probe Number = 0, T = 20.906000 C 13:51:39 Temperature Measurement, Probe Number = 1, T = 21.473000 C 13:51:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.91 P2 = 3458_Meas_Junction, Value = 21.47 13:51:39 Integrated Voltage Measurement... 13:52:12 Voltage Offset Correction: v_off_ini = -0.000001930 V, v_off_fin = -0.000000597 V 13:52:12 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143089491 Vs 13:52:12 Integrated Voltage Measurement... 13:52:45 Voltage Offset Correction: v_off_ini = -0.000001057 V, v_off_fin = -0.000002406 V 13:52:45 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143072731 Vs 13:52:46   Voltage Measurement, V = 0.000000 V 13:52:47 Temperature Measurement, Probe Number = 0, T = 20.899000 C 13:52:48 Temperature Measurement, Probe Number = 1, T = 21.474000 C 13:52:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.90 P2 = 3458_Meas_Junction, Value = 21.47 13:52:48 Integrated Voltage Measurement... 13:53:18 Voltage Offset Correction: v_off_ini = -0.000002265 V, v_off_fin = -0.000000682 V 13:53:18 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143097716 Vs 13:53:18 Integrated Voltage Measurement... 13:53:50 Voltage Offset Correction: v_off_ini = -0.000000821 V, v_off_fin = -0.000002137 V 13:53:50 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143078648 Vs