SLAC Magnetic Measurements Date: 10-29-2020 Time: 13:45:30 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_007_Cell_33 Serial Number: PC33408 Run Number: 12 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 12 13:45:48 Ambient Measurement Device(s) Being Used, type = None 13:45:48 Magnet Voltage Measurement Device(s) Being Used, type = None 13:45:48 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 13:45:48 XMAG Device(s) Being Used, type = None 13:45:48 Ambient Measurement Device(s) Being Used, type = None 13:45:51   Voltage Measurement, V = 0.000000 V 13:45:52 Temperature Measurement, Probe Number = 0, T = 20.965000 C 13:45:53 Temperature Measurement, Probe Number = 1, T = 21.827000 C 13:45:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.96 P2 = 3458_Meas_Junction, Value = 21.83 13:45:53 Integrated Voltage Measurement... 13:46:18 Voltage Offset Correction: v_off_ini = -0.000000406 V, v_off_fin = 0.000000788 V 13:46:18 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.143290194 Vs 13:46:18 Integrated Voltage Measurement... 13:46:54 Voltage Offset Correction: v_off_ini = 0.000000478 V, v_off_fin = -0.000000329 V 13:46:54 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143234445 Vs 13:46:55   Voltage Measurement, V = 0.000000 V 13:46:56 Temperature Measurement, Probe Number = 0, T = 20.938000 C 13:46:56 Temperature Measurement, Probe Number = 1, T = 21.831000 C 13:46:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.94 P2 = 3458_Meas_Junction, Value = 21.83 13:46:56 Integrated Voltage Measurement... 13:47:29 Voltage Offset Correction: v_off_ini = -0.000000543 V, v_off_fin = 0.000000429 V 13:47:29 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143259588 Vs 13:47:29 Integrated Voltage Measurement... 13:48:02 Voltage Offset Correction: v_off_ini = 0.000000234 V, v_off_fin = -0.000000748 V 13:48:02 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143235228 Vs 13:48:03   Voltage Measurement, V = 0.000000 V 13:48:03 Temperature Measurement, Probe Number = 0, T = 20.939000 C 13:48:04 Temperature Measurement, Probe Number = 1, T = 21.830000 C 13:48:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.94 P2 = 3458_Meas_Junction, Value = 21.83 13:48:04 Integrated Voltage Measurement... 13:48:36 Voltage Offset Correction: v_off_ini = -0.000000613 V, v_off_fin = -0.000000817 V 13:48:36 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143259009 Vs 13:48:36 Integrated Voltage Measurement... 13:49:09 Voltage Offset Correction: v_off_ini = 0.000000093 V, v_off_fin = -0.000001813 V 13:49:09 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143235967 Vs 13:49:10   Voltage Measurement, V = 0.000000 V 13:49:10 Temperature Measurement, Probe Number = 0, T = 20.934000 C 13:49:11 Temperature Measurement, Probe Number = 1, T = 21.826000 C 13:49:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.93 P2 = 3458_Meas_Junction, Value = 21.83 13:49:11 Integrated Voltage Measurement... 13:49:43 Voltage Offset Correction: v_off_ini = -0.000000740 V, v_off_fin = 0.000000696 V 13:49:43 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143260777 Vs 13:49:43 Integrated Voltage Measurement... 13:50:14 Voltage Offset Correction: v_off_ini = 0.000000277 V, v_off_fin = -0.000001607 V 13:50:14 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143230015 Vs 13:50:15   Voltage Measurement, V = 0.000000 V 13:50:16 Temperature Measurement, Probe Number = 0, T = 20.939000 C 13:50:16 Temperature Measurement, Probe Number = 1, T = 21.833000 C 13:50:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.94 P2 = 3458_Meas_Junction, Value = 21.83 13:50:16 Integrated Voltage Measurement... 13:50:48 Voltage Offset Correction: v_off_ini = -0.000000695 V, v_off_fin = 0.000000468 V 13:50:48 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143268504 Vs 13:50:48 Integrated Voltage Measurement... 13:51:19 Voltage Offset Correction: v_off_ini = 0.000000415 V, v_off_fin = -0.000001333 V 13:51:19 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143230055 Vs 13:51:20   Voltage Measurement, V = 0.000000 V 13:51:21 Temperature Measurement, Probe Number = 0, T = 20.949000 C 13:51:22 Temperature Measurement, Probe Number = 1, T = 21.833000 C 13:51:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.95 P2 = 3458_Meas_Junction, Value = 21.83 13:51:22 Integrated Voltage Measurement... 13:51:55 Voltage Offset Correction: v_off_ini = -0.000000590 V, v_off_fin = 0.000000798 V 13:51:55 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143258106 Vs 13:51:55 Integrated Voltage Measurement... 13:52:26 Voltage Offset Correction: v_off_ini = 0.000000325 V, v_off_fin = -0.000000928 V 13:52:26 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143227197 Vs 13:52:27   Voltage Measurement, V = 0.000000 V 13:52:28 Temperature Measurement, Probe Number = 0, T = 20.951000 C 13:52:28 Temperature Measurement, Probe Number = 1, T = 21.841000 C 13:52:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.95 P2 = 3458_Meas_Junction, Value = 21.84 13:52:28 Integrated Voltage Measurement... 13:53:01 Voltage Offset Correction: v_off_ini = -0.000000465 V, v_off_fin = 0.000000036 V 13:53:01 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143259799 Vs 13:53:01 Integrated Voltage Measurement... 13:53:32 Voltage Offset Correction: v_off_ini = 0.000000295 V, v_off_fin = -0.000001634 V 13:53:32 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143230672 Vs 13:53:33   Voltage Measurement, V = 0.000000 V 13:53:33 Temperature Measurement, Probe Number = 0, T = 20.959000 C 13:53:34 Temperature Measurement, Probe Number = 1, T = 21.840000 C 13:53:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.96 P2 = 3458_Meas_Junction, Value = 21.84 13:53:34 Integrated Voltage Measurement... 13:54:05 Voltage Offset Correction: v_off_ini = -0.000000688 V, v_off_fin = 0.000000150 V 13:54:05 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143268319 Vs 13:54:05 Integrated Voltage Measurement... 13:54:37 Voltage Offset Correction: v_off_ini = 0.000000319 V, v_off_fin = -0.000001752 V 13:54:37 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143228232 Vs 13:54:38   Voltage Measurement, V = 0.000000 V 13:54:39 Temperature Measurement, Probe Number = 0, T = 20.953000 C 13:54:39 Temperature Measurement, Probe Number = 1, T = 21.838000 C 13:54:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.95 P2 = 3458_Meas_Junction, Value = 21.84 13:54:39 Integrated Voltage Measurement... 13:55:11 Voltage Offset Correction: v_off_ini = -0.000000569 V, v_off_fin = 0.000000185 V 13:55:11 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143261015 Vs 13:55:11 Integrated Voltage Measurement... 13:55:42 Voltage Offset Correction: v_off_ini = 0.000000227 V, v_off_fin = -0.000000815 V 13:55:42 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143228544 Vs 13:55:43   Voltage Measurement, V = 0.000000 V 13:55:43 Temperature Measurement, Probe Number = 0, T = 20.956000 C 13:55:44 Temperature Measurement, Probe Number = 1, T = 21.821000 C 13:55:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.96 P2 = 3458_Meas_Junction, Value = 21.82 13:55:44 Integrated Voltage Measurement... 13:56:16 Voltage Offset Correction: v_off_ini = -0.000000387 V, v_off_fin = 0.000000397 V 13:56:16 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143263529 Vs 13:56:16 Integrated Voltage Measurement... 13:56:49 Voltage Offset Correction: v_off_ini = 0.000000201 V, v_off_fin = -0.000001341 V 13:56:49 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143242975 Vs