SLAC Magnetic Measurements Date: 03-05-2021 Time: 12:41:55 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_006_Cell_26_Hysteresis Serial Number: PC33408 Run Number: 12 Measurement Device: Coil Operator: sda Comment: Gap cycled 3 times between 7.5 and 8 mm. 12:42:13 Ambient Measurement Device(s) Being Used, type = None 12:42:13 Magnet Voltage Measurement Device(s) Being Used, type = None 12:42:13 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 12:42:13 XMAG Device(s) Being Used, type = None 12:42:13 Ambient Measurement Device(s) Being Used, type = None 12:42:52   Voltage Measurement, V = 0.000000 V 12:42:53 Temperature Measurement, Probe Number = 0, T = 23.203000 C 12:42:54 Temperature Measurement, Probe Number = 1, T = 24.510000 C 12:42:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.20 P2 = 3458_Meas_Junction, Value = 24.51 12:42:54 Integrated Voltage Measurement... 12:43:20 Voltage Offset Correction: v_off_ini = 0.000002852 V, v_off_fin = 0.000003698 V 12:43:20 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.144504831 Vs 12:43:20 Integrated Voltage Measurement... 12:43:53 Voltage Offset Correction: v_off_ini = 0.000004573 V, v_off_fin = 0.000002565 V 12:43:53 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.144484926 Vs 12:43:54   Voltage Measurement, V = 0.000000 V 12:43:54 Temperature Measurement, Probe Number = 0, T = 23.188000 C 12:43:55 Temperature Measurement, Probe Number = 1, T = 24.519000 C 12:43:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.19 P2 = 3458_Meas_Junction, Value = 24.52 12:43:55 Integrated Voltage Measurement... 12:44:26 Voltage Offset Correction: v_off_ini = 0.000003287 V, v_off_fin = 0.000005838 V 12:44:26 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.144508530 Vs 12:44:26 Integrated Voltage Measurement... 12:44:59 Voltage Offset Correction: v_off_ini = 0.000004996 V, v_off_fin = 0.000002877 V 12:44:59 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.144495140 Vs 12:45:00   Voltage Measurement, V = 0.000000 V 12:45:01 Temperature Measurement, Probe Number = 0, T = 23.197000 C 12:45:01 Temperature Measurement, Probe Number = 1, T = 24.533000 C 12:45:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.20 P2 = 3458_Meas_Junction, Value = 24.53 12:45:01 Integrated Voltage Measurement... 12:45:33 Voltage Offset Correction: v_off_ini = 0.000003224 V, v_off_fin = 0.000005066 V 12:45:33 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.144503402 Vs 12:45:33 Integrated Voltage Measurement... 12:46:05 Voltage Offset Correction: v_off_ini = 0.000004833 V, v_off_fin = 0.000004155 V 12:46:05 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.144490324 Vs 12:46:06   Voltage Measurement, V = 0.000000 V 12:46:07 Temperature Measurement, Probe Number = 0, T = 23.207000 C 12:46:07 Temperature Measurement, Probe Number = 1, T = 24.489000 C 12:46:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.21 P2 = 3458_Meas_Junction, Value = 24.49 12:46:07 Integrated Voltage Measurement... 12:46:39 Voltage Offset Correction: v_off_ini = 0.000003363 V, v_off_fin = 0.000005163 V 12:46:39 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.144505049 Vs 12:46:39 Integrated Voltage Measurement... 12:47:12 Voltage Offset Correction: v_off_ini = 0.000004396 V, v_off_fin = 0.000002201 V 12:47:12 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.144483861 Vs 12:47:13   Voltage Measurement, V = 0.000000 V 12:47:14 Temperature Measurement, Probe Number = 0, T = 23.192000 C 12:47:14 Temperature Measurement, Probe Number = 1, T = 24.477000 C 12:47:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.19 P2 = 3458_Meas_Junction, Value = 24.48 12:47:14 Integrated Voltage Measurement... 12:47:48 Voltage Offset Correction: v_off_ini = 0.000003521 V, v_off_fin = 0.000004164 V 12:47:48 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.144506197 Vs 12:47:48 Integrated Voltage Measurement... 12:48:20 Voltage Offset Correction: v_off_ini = 0.000004590 V, v_off_fin = 0.000002637 V 12:48:20 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.144486396 Vs 12:48:21   Voltage Measurement, V = 0.000000 V 12:48:21 Temperature Measurement, Probe Number = 0, T = 23.194000 C 12:48:22 Temperature Measurement, Probe Number = 1, T = 24.506000 C 12:48:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.19 P2 = 3458_Meas_Junction, Value = 24.51 12:48:22 Integrated Voltage Measurement... 12:48:53 Voltage Offset Correction: v_off_ini = 0.000003129 V, v_off_fin = 0.000004743 V 12:48:53 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.144507147 Vs 12:48:53 Integrated Voltage Measurement... 12:49:25 Voltage Offset Correction: v_off_ini = 0.000004630 V, v_off_fin = 0.000002336 V 12:49:25 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.144482116 Vs 12:49:26   Voltage Measurement, V = 0.000000 V 12:49:26 Temperature Measurement, Probe Number = 0, T = 23.200000 C 12:49:27 Temperature Measurement, Probe Number = 1, T = 24.525000 C 12:49:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.20 P2 = 3458_Meas_Junction, Value = 24.52 12:49:27 Integrated Voltage Measurement... 12:49:59 Voltage Offset Correction: v_off_ini = 0.000003328 V, v_off_fin = 0.000005073 V 12:49:59 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.144508526 Vs 12:49:59 Integrated Voltage Measurement... 12:50:33 Voltage Offset Correction: v_off_ini = 0.000004852 V, v_off_fin = 0.000003583 V 12:50:33 Integrated Voltage Measurement Delta Gap = -0.0030006 m VT = -0.097651240 Vs 12:50:34   Voltage Measurement, V = 0.000000 V 12:50:34 Temperature Measurement, Probe Number = 0, T = 23.199000 C 12:50:35 Temperature Measurement, Probe Number = 1, T = 24.538000 C 12:50:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.20 P2 = 3458_Meas_Junction, Value = 24.54 12:50:35 Integrated Voltage Measurement... 12:51:43 Voltage Offset Correction: v_off_ini = 0.000002998 V, v_off_fin = 0.000005539 V 12:51:43 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.144506328 Vs 12:51:43 Integrated Voltage Measurement... 12:52:17 Voltage Offset Correction: v_off_ini = 0.000004690 V, v_off_fin = 0.000002686 V 12:52:17 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.144487599 Vs 12:52:18   Voltage Measurement, V = 0.000000 V 12:52:18 Temperature Measurement, Probe Number = 0, T = 23.226000 C 12:52:19 Temperature Measurement, Probe Number = 1, T = 24.543000 C 12:52:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.23 P2 = 3458_Meas_Junction, Value = 24.54 12:52:19 Integrated Voltage Measurement... 12:52:52 Voltage Offset Correction: v_off_ini = 0.000003580 V, v_off_fin = 0.000006010 V 12:52:52 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.144507416 Vs 12:52:52 Integrated Voltage Measurement... 12:53:24 Voltage Offset Correction: v_off_ini = 0.000004848 V, v_off_fin = 0.000003170 V 12:53:24 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.144487604 Vs 12:53:25   Voltage Measurement, V = 0.000000 V 12:53:26 Temperature Measurement, Probe Number = 0, T = 23.240000 C 12:53:26 Temperature Measurement, Probe Number = 1, T = 24.552000 C 12:53:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.24 P2 = 3458_Meas_Junction, Value = 24.55 12:53:26 Integrated Voltage Measurement... 12:53:59 Voltage Offset Correction: v_off_ini = 0.000003580 V, v_off_fin = 0.000005474 V 12:53:59 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.144504572 Vs 12:53:59 Integrated Voltage Measurement... 12:54:33 Voltage Offset Correction: v_off_ini = 0.000004766 V, v_off_fin = 0.000002465 V 12:54:33 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.144476869 Vs