SLAC Magnetic Measurements Date: 10-06-2020 Time: 11:46:07 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_006_Cell_26 Serial Number: PC33408 Run Number: 10 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 10 11:46:09 Ambient Measurement Device(s) Being Used, type = None 11:46:09 Magnet Voltage Measurement Device(s) Being Used, type = None 11:46:10 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 11:46:10 XMAG Device(s) Being Used, type = None 11:46:10 Ambient Measurement Device(s) Being Used, type = None 11:47:59   Voltage Measurement, V = 0.000000 V 11:48:00 Temperature Measurement, Probe Number = 0, T = 20.432000 C 11:48:01 Temperature Measurement, Probe Number = 1, T = 21.388000 C 11:48:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.43 P2 = 3458_Meas_Junction, Value = 21.39 11:48:01 Integrated Voltage Measurement... 11:48:32 Voltage Offset Correction: v_off_ini = -0.000001358 V, v_off_fin = -0.000000040 V 11:48:33 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.144520205 Vs 11:48:33 Integrated Voltage Measurement... 11:49:06 Voltage Offset Correction: v_off_ini = -0.000000005 V, v_off_fin = -0.000002208 V 11:49:06 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.144522981 Vs 11:49:07   Voltage Measurement, V = 0.000000 V 11:49:08 Temperature Measurement, Probe Number = 0, T = 20.420000 C 11:49:08 Temperature Measurement, Probe Number = 1, T = 21.378000 C 11:49:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.42 P2 = 3458_Meas_Junction, Value = 21.38 11:49:08 Integrated Voltage Measurement... 11:50:00 Voltage Offset Correction: v_off_ini = -0.000000927 V, v_off_fin = -0.000000008 V 11:50:00 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.144538811 Vs 11:50:00 Integrated Voltage Measurement... 11:50:36 Voltage Offset Correction: v_off_ini = -0.000000109 V, v_off_fin = -0.000000869 V 11:50:36 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.144510916 Vs 11:50:37   Voltage Measurement, V = 0.000000 V 11:50:38 Temperature Measurement, Probe Number = 0, T = 20.473000 C 11:50:38 Temperature Measurement, Probe Number = 1, T = 21.361000 C 11:50:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.47 P2 = 3458_Meas_Junction, Value = 21.36 11:50:38 Integrated Voltage Measurement... 11:51:10 Voltage Offset Correction: v_off_ini = -0.000001088 V, v_off_fin = -0.000000641 V 11:51:10 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.144517368 Vs 11:51:10 Integrated Voltage Measurement... 11:51:42 Voltage Offset Correction: v_off_ini = -0.000000069 V, v_off_fin = -0.000001991 V 11:51:42 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.144520126 Vs 11:51:43   Voltage Measurement, V = 0.000000 V 11:51:44 Temperature Measurement, Probe Number = 0, T = 20.447000 C 11:51:45 Temperature Measurement, Probe Number = 1, T = 21.371000 C 11:51:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.45 P2 = 3458_Meas_Junction, Value = 21.37 11:51:45 Integrated Voltage Measurement... 11:52:17 Voltage Offset Correction: v_off_ini = -0.000001055 V, v_off_fin = -0.000000479 V 11:52:18 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.144524362 Vs 11:52:18 Integrated Voltage Measurement... 11:52:48 Voltage Offset Correction: v_off_ini = -0.000000025 V, v_off_fin = -0.000001983 V 11:52:48 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.144517112 Vs 11:52:49   Voltage Measurement, V = 0.000000 V 11:52:50 Temperature Measurement, Probe Number = 0, T = 20.404000 C 11:52:50 Temperature Measurement, Probe Number = 1, T = 21.380000 C 11:52:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.40 P2 = 3458_Meas_Junction, Value = 21.38 11:52:50 Integrated Voltage Measurement... 11:53:22 Voltage Offset Correction: v_off_ini = -0.000001342 V, v_off_fin = 0.000000135 V 11:53:22 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.144535288 Vs 11:53:22 Integrated Voltage Measurement... 11:53:54 Voltage Offset Correction: v_off_ini = -0.000000313 V, v_off_fin = -0.000002223 V 11:53:54 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.144512814 Vs 11:53:55   Voltage Measurement, V = 0.000000 V 11:53:56 Temperature Measurement, Probe Number = 0, T = 20.372000 C 11:53:56 Temperature Measurement, Probe Number = 1, T = 21.387000 C 11:53:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.37 P2 = 3458_Meas_Junction, Value = 21.39 11:53:56 Integrated Voltage Measurement... 11:54:28 Voltage Offset Correction: v_off_ini = -0.000001347 V, v_off_fin = 0.000000184 V 11:54:28 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.144538189 Vs 11:54:28 Integrated Voltage Measurement... 11:55:00 Voltage Offset Correction: v_off_ini = 0.000000021 V, v_off_fin = -0.000001452 V 11:55:00 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.144517634 Vs 11:55:01   Voltage Measurement, V = 0.000000 V 11:55:01 Temperature Measurement, Probe Number = 0, T = 20.346000 C 11:55:02 Temperature Measurement, Probe Number = 1, T = 21.391000 C 11:55:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.35 P2 = 3458_Meas_Junction, Value = 21.39 11:55:02 Integrated Voltage Measurement... 11:55:34 Voltage Offset Correction: v_off_ini = -0.000001153 V, v_off_fin = -0.000000212 V 11:55:34 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.144520724 Vs 11:55:34 Integrated Voltage Measurement... 11:56:06 Voltage Offset Correction: v_off_ini = -0.000000084 V, v_off_fin = -0.000002946 V 11:56:06 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.144505296 Vs 11:56:07   Voltage Measurement, V = 0.000000 V 11:56:08 Temperature Measurement, Probe Number = 0, T = 20.328000 C 11:56:09 Temperature Measurement, Probe Number = 1, T = 21.399000 C 11:56:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.33 P2 = 3458_Meas_Junction, Value = 21.40 11:56:09 Integrated Voltage Measurement... 11:56:41 Voltage Offset Correction: v_off_ini = -0.000001242 V, v_off_fin = 0.000000026 V 11:56:41 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.144531775 Vs 11:56:41 Integrated Voltage Measurement... 11:57:17 Voltage Offset Correction: v_off_ini = -0.000000103 V, v_off_fin = -0.000001860 V 11:57:17 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.144512936 Vs 11:57:18   Voltage Measurement, V = 0.000000 V 11:57:18 Temperature Measurement, Probe Number = 0, T = 20.314000 C 11:57:19 Temperature Measurement, Probe Number = 1, T = 21.399000 C 11:57:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.31 P2 = 3458_Meas_Junction, Value = 21.40 11:57:19 Integrated Voltage Measurement... 11:57:50 Voltage Offset Correction: v_off_ini = -0.000001572 V, v_off_fin = 0.000000152 V 11:57:50 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.144532910 Vs 11:57:50 Integrated Voltage Measurement... 11:58:23 Voltage Offset Correction: v_off_ini = -0.000000056 V, v_off_fin = -0.000001447 V 11:58:23 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.144511577 Vs 11:58:24   Voltage Measurement, V = 0.000000 V 11:58:25 Temperature Measurement, Probe Number = 0, T = 20.311000 C 11:58:26 Temperature Measurement, Probe Number = 1, T = 21.385000 C 11:58:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.31 P2 = 3458_Meas_Junction, Value = 21.39 11:58:26 Integrated Voltage Measurement... 11:58:58 Voltage Offset Correction: v_off_ini = -0.000001131 V, v_off_fin = 0.000000464 V 11:58:58 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.144531338 Vs 11:58:58 Integrated Voltage Measurement... 11:59:31 Voltage Offset Correction: v_off_ini = 0.000000116 V, v_off_fin = -0.000001630 V 11:59:31 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.144519085 Vs