SLAC Magnetic Measurements Date: 10-19-2020 Time: 12:05:09 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_005_Cell_29_Upstairs Serial Number: PC33408 Run Number: 4 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement upstairs, cable through switch. Full Set 4 12:05:28 Ambient Measurement Device(s) Being Used, type = None 12:05:28 Magnet Voltage Measurement Device(s) Being Used, type = None 12:05:28 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 12:05:28 XMAG Device(s) Being Used, type = None 12:05:28 Ambient Measurement Device(s) Being Used, type = None 12:05:38   Voltage Measurement, V = 0.000000 V 12:05:39 Temperature Measurement, Probe Number = 0, T = 23.424000 C 12:05:40 Temperature Measurement, Probe Number = 1, T = 23.845000 C 12:05:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.42 P2 = 3458_Meas_Junction, Value = 23.84 12:05:40 Integrated Voltage Measurement... 12:06:15 Voltage Offset Correction: v_off_ini = 0.000010273 V, v_off_fin = 0.000012581 V 12:06:15 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.144018267 Vs 12:06:15 Integrated Voltage Measurement... 12:07:34 Voltage Offset Correction: v_off_ini = 0.000010499 V, v_off_fin = 0.000008774 V 12:07:34 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.144056524 Vs 12:07:35   Voltage Measurement, V = 0.000000 V 12:07:36 Temperature Measurement, Probe Number = 0, T = 23.397000 C 12:07:36 Temperature Measurement, Probe Number = 1, T = 23.850000 C 12:07:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.40 P2 = 3458_Meas_Junction, Value = 23.85 12:07:36 Integrated Voltage Measurement... 12:08:11 Voltage Offset Correction: v_off_ini = 0.000010236 V, v_off_fin = 0.000011218 V 12:08:11 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.144033649 Vs 12:08:11 Integrated Voltage Measurement... 12:08:49 Voltage Offset Correction: v_off_ini = 0.000011111 V, v_off_fin = 0.000008383 V 12:08:49 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.144048327 Vs 12:08:50   Voltage Measurement, V = 0.000000 V 12:08:51 Temperature Measurement, Probe Number = 0, T = 23.371000 C 12:08:51 Temperature Measurement, Probe Number = 1, T = 23.851000 C 12:08:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.37 P2 = 3458_Meas_Junction, Value = 23.85 12:08:51 Integrated Voltage Measurement... 12:09:22 Voltage Offset Correction: v_off_ini = 0.000010077 V, v_off_fin = 0.000010597 V 12:09:22 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.144039820 Vs 12:09:22 Integrated Voltage Measurement... 12:09:55 Voltage Offset Correction: v_off_ini = 0.000011299 V, v_off_fin = 0.000009808 V 12:09:55 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.144042614 Vs 12:09:56   Voltage Measurement, V = 0.000000 V 12:09:57 Temperature Measurement, Probe Number = 0, T = 23.358000 C 12:09:57 Temperature Measurement, Probe Number = 1, T = 23.854000 C 12:09:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.36 P2 = 3458_Meas_Junction, Value = 23.85 12:09:57 Integrated Voltage Measurement... 12:10:31 Voltage Offset Correction: v_off_ini = 0.000010074 V, v_off_fin = 0.000011992 V 12:10:31 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.144031664 Vs 12:10:31 Integrated Voltage Measurement... 12:11:15 Voltage Offset Correction: v_off_ini = 0.000010992 V, v_off_fin = 0.000010439 V 12:11:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.144043184 Vs 12:11:16   Voltage Measurement, V = 0.000000 V 12:11:16 Temperature Measurement, Probe Number = 0, T = 23.346000 C 12:11:17 Temperature Measurement, Probe Number = 1, T = 23.840000 C 12:11:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.35 P2 = 3458_Meas_Junction, Value = 23.84 12:11:17 Integrated Voltage Measurement... 12:11:50 Voltage Offset Correction: v_off_ini = 0.000010317 V, v_off_fin = 0.000011785 V 12:11:50 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.144029868 Vs 12:11:50 Integrated Voltage Measurement... 12:12:22 Voltage Offset Correction: v_off_ini = 0.000011136 V, v_off_fin = 0.000010078 V 12:12:22 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.144046078 Vs 12:12:23   Voltage Measurement, V = 0.000000 V 12:12:24 Temperature Measurement, Probe Number = 0, T = 23.349000 C 12:12:25 Temperature Measurement, Probe Number = 1, T = 23.836000 C 12:12:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.35 P2 = 3458_Meas_Junction, Value = 23.84 12:12:25 Integrated Voltage Measurement... 12:12:58 Voltage Offset Correction: v_off_ini = 0.000010134 V, v_off_fin = 0.000011300 V 12:12:58 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.144037212 Vs 12:12:58 Integrated Voltage Measurement... 12:13:30 Voltage Offset Correction: v_off_ini = 0.000011042 V, v_off_fin = 0.000010346 V 12:13:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.144033288 Vs 12:13:31   Voltage Measurement, V = 0.000000 V 12:13:32 Temperature Measurement, Probe Number = 0, T = 23.360000 C 12:13:32 Temperature Measurement, Probe Number = 1, T = 23.837000 C 12:13:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.36 P2 = 3458_Meas_Junction, Value = 23.84 12:13:32 Integrated Voltage Measurement... 12:14:06 Voltage Offset Correction: v_off_ini = 0.000010057 V, v_off_fin = 0.000011078 V 12:14:06 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.144035844 Vs 12:14:06 Integrated Voltage Measurement... 12:14:38 Voltage Offset Correction: v_off_ini = 0.000011420 V, v_off_fin = 0.000011116 V 12:14:38 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.144037623 Vs 12:14:39   Voltage Measurement, V = 0.000000 V 12:14:40 Temperature Measurement, Probe Number = 0, T = 23.361000 C 12:14:40 Temperature Measurement, Probe Number = 1, T = 23.835000 C 12:14:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.36 P2 = 3458_Meas_Junction, Value = 23.84 12:14:40 Integrated Voltage Measurement... 12:15:14 Voltage Offset Correction: v_off_ini = 0.000010301 V, v_off_fin = 0.000011391 V 12:15:14 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.144035860 Vs 12:15:14 Integrated Voltage Measurement... 12:15:46 Voltage Offset Correction: v_off_ini = 0.000011065 V, v_off_fin = 0.000010323 V 12:15:46 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.144041336 Vs 12:15:47   Voltage Measurement, V = 0.000000 V 12:15:47 Temperature Measurement, Probe Number = 0, T = 23.370000 C 12:15:48 Temperature Measurement, Probe Number = 1, T = 23.842000 C 12:15:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.37 P2 = 3458_Meas_Junction, Value = 23.84 12:15:48 Integrated Voltage Measurement... 12:16:20 Voltage Offset Correction: v_off_ini = 0.000009987 V, v_off_fin = 0.000012044 V 12:16:20 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.144028857 Vs 12:16:20 Integrated Voltage Measurement... 12:16:56 Voltage Offset Correction: v_off_ini = 0.000010967 V, v_off_fin = 0.000008748 V 12:16:56 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.144027769 Vs 12:16:57   Voltage Measurement, V = 0.000000 V 12:16:58 Temperature Measurement, Probe Number = 0, T = 23.367000 C 12:16:58 Temperature Measurement, Probe Number = 1, T = 23.839000 C 12:16:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.37 P2 = 3458_Meas_Junction, Value = 23.84 12:16:58 Integrated Voltage Measurement... 12:17:31 Voltage Offset Correction: v_off_ini = 0.000010239 V, v_off_fin = 0.000011760 V 12:17:31 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.144024664 Vs 12:17:31 Integrated Voltage Measurement... 12:18:02 Voltage Offset Correction: v_off_ini = 0.000011040 V, v_off_fin = 0.000010509 V 12:18:02 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.144030995 Vs