SLAC Magnetic Measurements Date: 09-23-2020 Time: 16:44:36 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_005_Cell_29_Upstairs Serial Number: PC33408 Run Number: 2 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement upstairs, cable straight into 3458A. Set 2 16:44:39 Ambient Measurement Device(s) Being Used, type = None 16:44:39 Magnet Voltage Measurement Device(s) Being Used, type = None 16:44:39 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 16:44:39 XMAG Device(s) Being Used, type = None 16:44:39 Ambient Measurement Device(s) Being Used, type = None 16:44:51   Voltage Measurement, V = 0.000000 V 16:44:51 Temperature Measurement, Probe Number = 0, T = 22.753000 C 16:44:52 Temperature Measurement, Probe Number = 1, T = 23.481000 C 16:44:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.75 P2 = 3458_Meas_Junction, Value = 23.48 16:44:52 Integrated Voltage Measurement... 16:45:20 Voltage Offset Correction: v_off_ini = 0.000002103 V, v_off_fin = 0.000002730 V 16:45:20 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.144086397 Vs 16:45:20 Integrated Voltage Measurement... 16:45:51 Voltage Offset Correction: v_off_ini = 0.000002337 V, v_off_fin = 0.000000639 V 16:45:51 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.144078694 Vs 16:45:52   Voltage Measurement, V = 0.000000 V 16:45:52 Temperature Measurement, Probe Number = 0, T = 22.747000 C 16:45:53 Temperature Measurement, Probe Number = 1, T = 23.479000 C 16:45:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.75 P2 = 3458_Meas_Junction, Value = 23.48 16:45:53 Integrated Voltage Measurement... 16:46:27 Voltage Offset Correction: v_off_ini = 0.000001711 V, v_off_fin = 0.000002488 V 16:46:27 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.144062978 Vs 16:46:27 Integrated Voltage Measurement... 16:46:58 Voltage Offset Correction: v_off_ini = 0.000002610 V, v_off_fin = 0.000001575 V 16:46:58 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.144071468 Vs 16:46:59   Voltage Measurement, V = 0.000000 V 16:47:00 Temperature Measurement, Probe Number = 0, T = 22.743000 C 16:47:01 Temperature Measurement, Probe Number = 1, T = 23.489000 C 16:47:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.74 P2 = 3458_Meas_Junction, Value = 23.49 16:47:01 Integrated Voltage Measurement... 16:47:33 Voltage Offset Correction: v_off_ini = 0.000001693 V, v_off_fin = 0.000002370 V 16:47:33 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.144081316 Vs 16:47:33 Integrated Voltage Measurement... 16:48:06 Voltage Offset Correction: v_off_ini = 0.000002624 V, v_off_fin = 0.000001624 V 16:48:06 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.144091887 Vs 16:48:07   Voltage Measurement, V = 0.000000 V 16:48:07 Temperature Measurement, Probe Number = 0, T = 22.747000 C 16:48:08 Temperature Measurement, Probe Number = 1, T = 23.494000 C 16:48:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.75 P2 = 3458_Meas_Junction, Value = 23.49 16:48:08 Integrated Voltage Measurement... 16:48:40 Voltage Offset Correction: v_off_ini = 0.000001617 V, v_off_fin = 0.000003136 V 16:48:40 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.144073514 Vs 16:48:40 Integrated Voltage Measurement... 16:49:15 Voltage Offset Correction: v_off_ini = 0.000002387 V, v_off_fin = 0.000001198 V 16:49:15 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.144072650 Vs 16:49:16   Voltage Measurement, V = 0.000000 V 16:49:16 Temperature Measurement, Probe Number = 0, T = 22.746000 C 16:49:17 Temperature Measurement, Probe Number = 1, T = 23.498000 C 16:49:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.75 P2 = 3458_Meas_Junction, Value = 23.50 16:49:17 Integrated Voltage Measurement... 16:49:48 Voltage Offset Correction: v_off_ini = 0.000001625 V, v_off_fin = 0.000003451 V 16:49:48 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.144072116 Vs 16:49:48 Integrated Voltage Measurement... 16:50:20 Voltage Offset Correction: v_off_ini = 0.000002530 V, v_off_fin = 0.000000072 V 16:50:20 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.144062871 Vs 16:50:21   Voltage Measurement, V = 0.000000 V 16:50:22 Temperature Measurement, Probe Number = 0, T = 22.744000 C 16:50:23 Temperature Measurement, Probe Number = 1, T = 23.517000 C 16:50:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.74 P2 = 3458_Meas_Junction, Value = 23.52 16:50:23 Integrated Voltage Measurement... 16:50:55 Voltage Offset Correction: v_off_ini = 0.000001540 V, v_off_fin = 0.000003992 V 16:50:55 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.144068438 Vs 16:50:55 Integrated Voltage Measurement... 16:51:27 Voltage Offset Correction: v_off_ini = 0.000002599 V, v_off_fin = 0.000001062 V 16:51:27 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.144074311 Vs 16:51:28   Voltage Measurement, V = 0.000000 V 16:51:29 Temperature Measurement, Probe Number = 0, T = 22.735000 C 16:51:29 Temperature Measurement, Probe Number = 1, T = 23.535000 C 16:51:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.73 P2 = 3458_Meas_Junction, Value = 23.54 16:51:29 Integrated Voltage Measurement... 16:52:03 Voltage Offset Correction: v_off_ini = 0.000001838 V, v_off_fin = 0.000003396 V 16:52:03 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.144069428 Vs 16:52:03 Integrated Voltage Measurement... 16:52:34 Voltage Offset Correction: v_off_ini = 0.000002722 V, v_off_fin = 0.000000512 V 16:52:34 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.144068480 Vs 16:52:35   Voltage Measurement, V = 0.000000 V 16:52:36 Temperature Measurement, Probe Number = 0, T = 22.732000 C 16:52:36 Temperature Measurement, Probe Number = 1, T = 23.544000 C 16:52:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.73 P2 = 3458_Meas_Junction, Value = 23.54 16:52:36 Integrated Voltage Measurement... 16:53:08 Voltage Offset Correction: v_off_ini = 0.000001678 V, v_off_fin = 0.000003327 V 16:53:08 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.144078599 Vs 16:53:08 Integrated Voltage Measurement... 16:53:40 Voltage Offset Correction: v_off_ini = 0.000002731 V, v_off_fin = 0.000001072 V 16:53:40 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.144068697 Vs 16:53:41   Voltage Measurement, V = 0.000000 V 16:53:41 Temperature Measurement, Probe Number = 0, T = 22.721000 C 16:53:42 Temperature Measurement, Probe Number = 1, T = 23.552000 C 16:53:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.72 P2 = 3458_Meas_Junction, Value = 23.55 16:53:42 Integrated Voltage Measurement... 16:54:14 Voltage Offset Correction: v_off_ini = 0.000001927 V, v_off_fin = 0.000002782 V 16:54:14 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.144066711 Vs 16:54:14 Integrated Voltage Measurement... 16:54:47 Voltage Offset Correction: v_off_ini = 0.000002584 V, v_off_fin = -0.000000403 V 16:54:47 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.144069904 Vs 16:54:48   Voltage Measurement, V = 0.000000 V 16:54:48 Temperature Measurement, Probe Number = 0, T = 22.725000 C 16:54:49 Temperature Measurement, Probe Number = 1, T = 23.554000 C 16:54:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.73 P2 = 3458_Meas_Junction, Value = 23.55 16:54:49 Integrated Voltage Measurement... 16:55:21 Voltage Offset Correction: v_off_ini = 0.000001763 V, v_off_fin = 0.000003427 V 16:55:21 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.144065955 Vs 16:55:21 Integrated Voltage Measurement... 16:55:52 Voltage Offset Correction: v_off_ini = 0.000002474 V, v_off_fin = 0.000000727 V 16:55:52 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.144059178 Vs