SLAC Magnetic Measurements Date: 01-20-2021 Time: 15:06:38 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_004_Cell_27 Serial Number: PC33408 Run Number: 16 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 16, no beam between 15 & 16 15:06:55 Ambient Measurement Device(s) Being Used, type = None 15:06:55 Magnet Voltage Measurement Device(s) Being Used, type = None 15:06:56 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:06:56 XMAG Device(s) Being Used, type = None 15:06:56 Ambient Measurement Device(s) Being Used, type = None 15:06:58   Voltage Measurement, V = 0.000000 V 15:06:58 Temperature Measurement, Probe Number = 0, T = 20.331000 C 15:06:59 Temperature Measurement, Probe Number = 1, T = 21.723000 C 15:06:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.33 P2 = 3458_Meas_Junction, Value = 21.72 15:06:59 Integrated Voltage Measurement... 15:07:26 Voltage Offset Correction: v_off_ini = 0.000000537 V, v_off_fin = 0.000002032 V 15:07:26 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143449128 Vs 15:07:26 Integrated Voltage Measurement... 15:07:59 Voltage Offset Correction: v_off_ini = 0.000000890 V, v_off_fin = -0.000001622 V 15:07:59 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143412402 Vs 15:08:00   Voltage Measurement, V = 0.000000 V 15:08:01 Temperature Measurement, Probe Number = 0, T = 20.341000 C 15:08:02 Temperature Measurement, Probe Number = 1, T = 21.711000 C 15:08:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.34 P2 = 3458_Meas_Junction, Value = 21.71 15:08:02 Integrated Voltage Measurement... 15:08:34 Voltage Offset Correction: v_off_ini = -0.000000138 V, v_off_fin = 0.000001343 V 15:08:34 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143440092 Vs 15:08:34 Integrated Voltage Measurement... 15:09:07 Voltage Offset Correction: v_off_ini = 0.000000966 V, v_off_fin = -0.000001375 V 15:09:07 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143411943 Vs 15:09:08   Voltage Measurement, V = 0.000000 V 15:09:08 Temperature Measurement, Probe Number = 0, T = 20.380000 C 15:09:09 Temperature Measurement, Probe Number = 1, T = 21.711000 C 15:09:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.38 P2 = 3458_Meas_Junction, Value = 21.71 15:09:09 Integrated Voltage Measurement... 15:09:57 Voltage Offset Correction: v_off_ini = -0.000000056 V, v_off_fin = 0.000001013 V 15:09:57 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143452965 Vs 15:09:57 Integrated Voltage Measurement... 15:10:26 Voltage Offset Correction: v_off_ini = 0.000000712 V, v_off_fin = -0.000001093 V 15:10:26 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143411864 Vs 15:10:27   Voltage Measurement, V = 0.000000 V 15:10:28 Temperature Measurement, Probe Number = 0, T = 20.386000 C 15:10:29 Temperature Measurement, Probe Number = 1, T = 21.632000 C 15:10:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.39 P2 = 3458_Meas_Junction, Value = 21.63 15:10:29 Integrated Voltage Measurement... 15:10:59 Voltage Offset Correction: v_off_ini = -0.000000575 V, v_off_fin = 0.000001114 V 15:10:59 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143434673 Vs 15:10:59 Integrated Voltage Measurement... 15:11:30 Voltage Offset Correction: v_off_ini = 0.000000894 V, v_off_fin = -0.000001455 V 15:11:30 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143420487 Vs 15:11:31   Voltage Measurement, V = 0.000000 V 15:11:31 Temperature Measurement, Probe Number = 0, T = 20.400000 C 15:11:32 Temperature Measurement, Probe Number = 1, T = 21.649000 C 15:11:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.40 P2 = 3458_Meas_Junction, Value = 21.65 15:11:32 Integrated Voltage Measurement... 15:12:03 Voltage Offset Correction: v_off_ini = -0.000000511 V, v_off_fin = 0.000001481 V 15:12:03 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143435017 Vs 15:12:03 Integrated Voltage Measurement... 15:12:34 Voltage Offset Correction: v_off_ini = 0.000000637 V, v_off_fin = -0.000001462 V 15:12:35 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143406566 Vs 15:12:36   Voltage Measurement, V = 0.000000 V 15:12:36 Temperature Measurement, Probe Number = 0, T = 20.401000 C 15:12:37 Temperature Measurement, Probe Number = 1, T = 21.667000 C 15:12:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.40 P2 = 3458_Meas_Junction, Value = 21.67 15:12:37 Integrated Voltage Measurement... 15:13:11 Voltage Offset Correction: v_off_ini = -0.000000589 V, v_off_fin = 0.000001006 V 15:13:11 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143438963 Vs 15:13:11 Integrated Voltage Measurement... 15:13:41 Voltage Offset Correction: v_off_ini = 0.000000920 V, v_off_fin = -0.000001943 V 15:13:41 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143414710 Vs 15:13:42   Voltage Measurement, V = 0.000000 V 15:13:42 Temperature Measurement, Probe Number = 0, T = 20.404000 C 15:13:43 Temperature Measurement, Probe Number = 1, T = 21.681000 C 15:13:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.40 P2 = 3458_Meas_Junction, Value = 21.68 15:13:43 Integrated Voltage Measurement... 15:14:15 Voltage Offset Correction: v_off_ini = -0.000000949 V, v_off_fin = 0.000001514 V 15:14:15 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143449916 Vs 15:14:15 Integrated Voltage Measurement... 15:14:45 Voltage Offset Correction: v_off_ini = 0.000000765 V, v_off_fin = -0.000000896 V 15:14:46 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143410756 Vs 15:14:47   Voltage Measurement, V = 0.000000 V 15:14:47 Temperature Measurement, Probe Number = 0, T = 20.403000 C 15:14:48 Temperature Measurement, Probe Number = 1, T = 21.688000 C 15:14:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.40 P2 = 3458_Meas_Junction, Value = 21.69 15:14:48 Integrated Voltage Measurement... 15:15:19 Voltage Offset Correction: v_off_ini = -0.000000498 V, v_off_fin = 0.000002460 V 15:15:19 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143441241 Vs 15:15:19 Integrated Voltage Measurement... 15:15:58 Voltage Offset Correction: v_off_ini = 0.000000637 V, v_off_fin = -0.000001538 V 15:15:58 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143417875 Vs 15:15:59   Voltage Measurement, V = 0.000000 V 15:15:59 Temperature Measurement, Probe Number = 0, T = 20.400000 C 15:16:00 Temperature Measurement, Probe Number = 1, T = 21.686000 C 15:16:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.40 P2 = 3458_Meas_Junction, Value = 21.69 15:16:00 Integrated Voltage Measurement... 15:16:31 Voltage Offset Correction: v_off_ini = -0.000000635 V, v_off_fin = 0.000001557 V 15:16:31 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143451303 Vs 15:16:31 Integrated Voltage Measurement... 15:17:01 Voltage Offset Correction: v_off_ini = 0.000000882 V, v_off_fin = -0.000001735 V 15:17:01 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143422509 Vs 15:17:02   Voltage Measurement, V = 0.000000 V 15:17:03 Temperature Measurement, Probe Number = 0, T = 20.397000 C 15:17:03 Temperature Measurement, Probe Number = 1, T = 21.680000 C 15:17:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.40 P2 = 3458_Meas_Junction, Value = 21.68 15:17:03 Integrated Voltage Measurement... 15:17:34 Voltage Offset Correction: v_off_ini = -0.000000700 V, v_off_fin = 0.000000896 V 15:17:34 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143449093 Vs 15:17:34 Integrated Voltage Measurement... 15:18:05 Voltage Offset Correction: v_off_ini = 0.000000749 V, v_off_fin = -0.000001649 V 15:18:05 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143427686 Vs