SLAC Magnetic Measurements Date: 01-07-2021 Time: 11:01:59 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_004_Cell_27 Serial Number: PC33408 Run Number: 15 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 15 11:02:16 Ambient Measurement Device(s) Being Used, type = None 11:02:16 Magnet Voltage Measurement Device(s) Being Used, type = None 11:02:17 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 11:02:17 XMAG Device(s) Being Used, type = None 11:02:17 Ambient Measurement Device(s) Being Used, type = None 11:02:51   Voltage Measurement, V = 0.000000 V 11:02:52 Temperature Measurement, Probe Number = 0, T = 20.156000 C 11:02:52 Temperature Measurement, Probe Number = 1, T = 21.299000 C 11:02:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.16 P2 = 3458_Meas_Junction, Value = 21.30 11:02:53 Integrated Voltage Measurement... 11:03:30 Voltage Offset Correction: v_off_ini = -0.000000482 V, v_off_fin = 0.000002007 V 11:03:30 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.143482922 Vs 11:03:30 Integrated Voltage Measurement... 11:04:02 Voltage Offset Correction: v_off_ini = 0.000000767 V, v_off_fin = -0.000001095 V 11:04:02 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.143497131 Vs 11:04:03   Voltage Measurement, V = 0.000000 V 11:04:04 Temperature Measurement, Probe Number = 0, T = 20.176000 C 11:04:05 Temperature Measurement, Probe Number = 1, T = 21.324000 C 11:04:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.18 P2 = 3458_Meas_Junction, Value = 21.32 11:04:05 Integrated Voltage Measurement... 11:04:38 Voltage Offset Correction: v_off_ini = -0.000000495 V, v_off_fin = 0.000001117 V 11:04:38 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143494431 Vs 11:04:38 Integrated Voltage Measurement... 11:05:09 Voltage Offset Correction: v_off_ini = 0.000000752 V, v_off_fin = -0.000001631 V 11:05:09 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143490472 Vs 11:05:10   Voltage Measurement, V = 0.000000 V 11:05:11 Temperature Measurement, Probe Number = 0, T = 20.205000 C 11:05:11 Temperature Measurement, Probe Number = 1, T = 21.339000 C 11:05:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.20 P2 = 3458_Meas_Junction, Value = 21.34 11:05:11 Integrated Voltage Measurement... 11:05:42 Voltage Offset Correction: v_off_ini = -0.000000823 V, v_off_fin = 0.000000657 V 11:05:42 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143513741 Vs 11:05:42 Integrated Voltage Measurement... 11:06:12 Voltage Offset Correction: v_off_ini = 0.000000849 V, v_off_fin = -0.000001071 V 11:06:12 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143487911 Vs 11:06:13   Voltage Measurement, V = 0.000000 V 11:06:14 Temperature Measurement, Probe Number = 0, T = 20.220000 C 11:06:14 Temperature Measurement, Probe Number = 1, T = 21.361000 C 11:06:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.22 P2 = 3458_Meas_Junction, Value = 21.36 11:06:14 Integrated Voltage Measurement... 11:06:46 Voltage Offset Correction: v_off_ini = -0.000000592 V, v_off_fin = 0.000001252 V 11:06:46 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.143497209 Vs 11:06:46 Integrated Voltage Measurement... 11:07:18 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = -0.000001889 V 11:07:18 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143486988 Vs 11:07:19   Voltage Measurement, V = 0.000000 V 11:07:19 Temperature Measurement, Probe Number = 0, T = 20.268000 C 11:07:20 Temperature Measurement, Probe Number = 1, T = 21.364000 C 11:07:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.27 P2 = 3458_Meas_Junction, Value = 21.36 11:07:20 Integrated Voltage Measurement... 11:07:52 Voltage Offset Correction: v_off_ini = -0.000000559 V, v_off_fin = 0.000001825 V 11:07:52 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143506327 Vs 11:07:52 Integrated Voltage Measurement... 11:08:23 Voltage Offset Correction: v_off_ini = 0.000000792 V, v_off_fin = -0.000001504 V 11:08:23 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143482472 Vs 11:08:24   Voltage Measurement, V = 0.000000 V 11:08:25 Temperature Measurement, Probe Number = 0, T = 20.288000 C 11:08:26 Temperature Measurement, Probe Number = 1, T = 21.397000 C 11:08:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.29 P2 = 3458_Meas_Junction, Value = 21.40 11:08:26 Integrated Voltage Measurement... 11:08:58 Voltage Offset Correction: v_off_ini = -0.000000654 V, v_off_fin = 0.000000567 V 11:08:58 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143516075 Vs 11:08:58 Integrated Voltage Measurement... 11:09:33 Voltage Offset Correction: v_off_ini = 0.000000767 V, v_off_fin = -0.000001315 V 11:09:33 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143481390 Vs 11:09:34   Voltage Measurement, V = 0.000000 V 11:09:34 Temperature Measurement, Probe Number = 0, T = 20.281000 C 11:09:35 Temperature Measurement, Probe Number = 1, T = 21.393000 C 11:09:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.28 P2 = 3458_Meas_Junction, Value = 21.39 11:09:35 Integrated Voltage Measurement... 11:10:06 Voltage Offset Correction: v_off_ini = -0.000000633 V, v_off_fin = 0.000001505 V 11:10:06 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.143494702 Vs 11:10:06 Integrated Voltage Measurement... 11:10:38 Voltage Offset Correction: v_off_ini = 0.000000997 V, v_off_fin = -0.000000836 V 11:10:38 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.143472636 Vs 11:10:39   Voltage Measurement, V = 0.000000 V 11:10:39 Temperature Measurement, Probe Number = 0, T = 20.271000 C 11:10:40 Temperature Measurement, Probe Number = 1, T = 21.412000 C 11:10:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.27 P2 = 3458_Meas_Junction, Value = 21.41 11:10:40 Integrated Voltage Measurement... 11:11:11 Voltage Offset Correction: v_off_ini = -0.000000770 V, v_off_fin = 0.000000057 V 11:11:11 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143496566 Vs 11:11:11 Integrated Voltage Measurement... 11:11:43 Voltage Offset Correction: v_off_ini = 0.000000766 V, v_off_fin = -0.000001364 V 11:11:43 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143475714 Vs 11:11:44   Voltage Measurement, V = 0.000000 V 11:11:45 Temperature Measurement, Probe Number = 0, T = 20.266000 C 11:11:45 Temperature Measurement, Probe Number = 1, T = 21.423000 C 11:11:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.27 P2 = 3458_Meas_Junction, Value = 21.42 11:11:45 Integrated Voltage Measurement... 11:12:20 Voltage Offset Correction: v_off_ini = -0.000000648 V, v_off_fin = 0.000001570 V 11:12:20 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143530451 Vs 11:12:20 Integrated Voltage Measurement... 11:12:54 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = -0.000001933 V 11:12:55 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143479919 Vs 11:12:55   Voltage Measurement, V = 0.000000 V 11:12:56 Temperature Measurement, Probe Number = 0, T = 20.260000 C 11:12:57 Temperature Measurement, Probe Number = 1, T = 21.431000 C 11:12:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.26 P2 = 3458_Meas_Junction, Value = 21.43 11:12:57 Integrated Voltage Measurement... 11:13:30 Voltage Offset Correction: v_off_ini = -0.000000759 V, v_off_fin = -0.000000016 V 11:13:30 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143525405 Vs 11:13:30 Integrated Voltage Measurement... 11:14:14 Voltage Offset Correction: v_off_ini = 0.000000600 V, v_off_fin = -0.000002623 V 11:14:14 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143471750 Vs