SLAC Magnetic Measurements Date: 10-20-2020 Time: 15:16:51 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_004_Cell_27 Serial Number: PC33408 Run Number: 11 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 11 15:17:09 Ambient Measurement Device(s) Being Used, type = None 15:17:09 Magnet Voltage Measurement Device(s) Being Used, type = None 15:17:09 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:17:09 XMAG Device(s) Being Used, type = None 15:17:09 Ambient Measurement Device(s) Being Used, type = None 15:17:39   Voltage Measurement, V = 0.000000 V 15:17:40 Temperature Measurement, Probe Number = 0, T = 20.660000 C 15:17:41 Temperature Measurement, Probe Number = 1, T = 21.822000 C 15:17:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.66 P2 = 3458_Meas_Junction, Value = 21.82 15:17:41 Integrated Voltage Measurement... 15:18:10 Voltage Offset Correction: v_off_ini = -0.000001343 V, v_off_fin = 0.000000274 V 15:18:10 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.143525405 Vs 15:18:10 Integrated Voltage Measurement... 15:18:49 Voltage Offset Correction: v_off_ini = -0.000000375 V, v_off_fin = -0.000002261 V 15:18:49 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143443652 Vs 15:18:50   Voltage Measurement, V = 0.000000 V 15:18:50 Temperature Measurement, Probe Number = 0, T = 20.651000 C 15:18:51 Temperature Measurement, Probe Number = 1, T = 21.783000 C 15:18:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.65 P2 = 3458_Meas_Junction, Value = 21.78 15:18:51 Integrated Voltage Measurement... 15:19:26 Voltage Offset Correction: v_off_ini = -0.000001473 V, v_off_fin = 0.000000376 V 15:19:27 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143478711 Vs 15:19:27 Integrated Voltage Measurement... 15:20:02 Voltage Offset Correction: v_off_ini = -0.000000332 V, v_off_fin = -0.000002979 V 15:20:02 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143450660 Vs 15:20:03   Voltage Measurement, V = 0.000000 V 15:20:04 Temperature Measurement, Probe Number = 0, T = 20.650000 C 15:20:05 Temperature Measurement, Probe Number = 1, T = 21.810000 C 15:20:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.65 P2 = 3458_Meas_Junction, Value = 21.81 15:20:05 Integrated Voltage Measurement... 15:20:37 Voltage Offset Correction: v_off_ini = -0.000001484 V, v_off_fin = 0.000000473 V 15:20:37 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143490455 Vs 15:20:37 Integrated Voltage Measurement... 15:21:34 Voltage Offset Correction: v_off_ini = -0.000000395 V, v_off_fin = -0.000001922 V 15:21:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143457849 Vs 15:21:35   Voltage Measurement, V = 0.000000 V 15:21:35 Temperature Measurement, Probe Number = 0, T = 20.683000 C 15:21:36 Temperature Measurement, Probe Number = 1, T = 21.829000 C 15:21:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.68 P2 = 3458_Meas_Junction, Value = 21.83 15:21:36 Integrated Voltage Measurement... 15:22:09 Voltage Offset Correction: v_off_ini = -0.000001447 V, v_off_fin = 0.000000440 V 15:22:09 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143478512 Vs 15:22:09 Integrated Voltage Measurement... 15:22:41 Voltage Offset Correction: v_off_ini = -0.000000043 V, v_off_fin = -0.000003112 V 15:22:41 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143455808 Vs 15:22:42   Voltage Measurement, V = 0.000000 V 15:22:43 Temperature Measurement, Probe Number = 0, T = 20.675000 C 15:22:43 Temperature Measurement, Probe Number = 1, T = 21.808000 C 15:22:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.68 P2 = 3458_Meas_Junction, Value = 21.81 15:22:43 Integrated Voltage Measurement... 15:23:22 Voltage Offset Correction: v_off_ini = -0.000001201 V, v_off_fin = 0.000001423 V 15:23:22 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.143486224 Vs 15:23:22 Integrated Voltage Measurement... 15:23:53 Voltage Offset Correction: v_off_ini = -0.000000282 V, v_off_fin = -0.000002412 V 15:23:53 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143451543 Vs 15:23:54   Voltage Measurement, V = 0.000000 V 15:23:55 Temperature Measurement, Probe Number = 0, T = 20.659000 C 15:23:56 Temperature Measurement, Probe Number = 1, T = 21.763000 C 15:23:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.66 P2 = 3458_Meas_Junction, Value = 21.76 15:23:56 Integrated Voltage Measurement... 15:24:28 Voltage Offset Correction: v_off_ini = -0.000001358 V, v_off_fin = 0.000000079 V 15:24:28 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.143473682 Vs 15:24:28 Integrated Voltage Measurement... 15:25:02 Voltage Offset Correction: v_off_ini = 0.000000169 V, v_off_fin = -0.000001544 V 15:25:02 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143463201 Vs 15:25:03   Voltage Measurement, V = 0.000000 V 15:25:03 Temperature Measurement, Probe Number = 0, T = 20.649000 C 15:25:04 Temperature Measurement, Probe Number = 1, T = 21.734000 C 15:25:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.65 P2 = 3458_Meas_Junction, Value = 21.73 15:25:04 Integrated Voltage Measurement... 15:25:36 Voltage Offset Correction: v_off_ini = -0.000001520 V, v_off_fin = -0.000000161 V 15:25:36 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143483105 Vs 15:25:36 Integrated Voltage Measurement... 15:26:07 Voltage Offset Correction: v_off_ini = 0.000000006 V, v_off_fin = -0.000002439 V 15:26:07 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143450093 Vs 15:26:08   Voltage Measurement, V = 0.000000 V 15:26:09 Temperature Measurement, Probe Number = 0, T = 20.645000 C 15:26:10 Temperature Measurement, Probe Number = 1, T = 21.720000 C 15:26:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.64 P2 = 3458_Meas_Junction, Value = 21.72 15:26:10 Integrated Voltage Measurement... 15:26:43 Voltage Offset Correction: v_off_ini = -0.000001335 V, v_off_fin = 0.000000184 V 15:26:43 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143481037 Vs 15:26:43 Integrated Voltage Measurement... 15:27:17 Voltage Offset Correction: v_off_ini = -0.000000071 V, v_off_fin = -0.000002267 V 15:27:17 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143450517 Vs 15:27:18   Voltage Measurement, V = 0.000000 V 15:27:19 Temperature Measurement, Probe Number = 0, T = 20.641000 C 15:27:20 Temperature Measurement, Probe Number = 1, T = 21.706000 C 15:27:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.64 P2 = 3458_Meas_Junction, Value = 21.71 15:27:20 Integrated Voltage Measurement... 15:27:52 Voltage Offset Correction: v_off_ini = -0.000001300 V, v_off_fin = 0.000000463 V 15:27:52 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143471224 Vs 15:27:52 Integrated Voltage Measurement... 15:28:24 Voltage Offset Correction: v_off_ini = 0.000000025 V, v_off_fin = -0.000002284 V 15:28:24 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143446359 Vs 15:28:25   Voltage Measurement, V = 0.000000 V 15:28:25 Temperature Measurement, Probe Number = 0, T = 20.637000 C 15:28:26 Temperature Measurement, Probe Number = 1, T = 21.694000 C 15:28:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.64 P2 = 3458_Meas_Junction, Value = 21.69 15:28:26 Integrated Voltage Measurement... 15:28:57 Voltage Offset Correction: v_off_ini = -0.000001758 V, v_off_fin = -0.000000276 V 15:28:57 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143474616 Vs 15:28:57 Integrated Voltage Measurement... 15:29:30 Voltage Offset Correction: v_off_ini = 0.000000093 V, v_off_fin = -0.000002516 V 15:29:30 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143454776 Vs