SLAC Magnetic Measurements Date: 01-30-2020 Time: 14:39:56 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_27_Tunnel Serial Number: 4 Run Number: 1 Measurement Device: Flex_Coil Operator: sda Comment: 1st Integral measurement in tunnel. Cell 27, SXU 4 14:39:59 Ambient Measurement Device(s) Being Used, type = None 14:39:59 Magnet Voltage Measurement Device(s) Being Used, type = None 14:39:59 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 14:39:59 XMAG Device(s) Being Used, type = None 14:39:59 Ambient Measurement Device(s) Being Used, type = None 14:40:31 8\ Voltage Measurement, V = 0.000000 V 14:40:32 Temperature Measurement, Probe Number = 0, T = 20.751000 C 14:40:33 Temperature Measurement, Probe Number = 1, T = 20.652000 C 14:40:33 Temperature Measurement, Probe Number = 2, T = 20.461000 C 14:40:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Lower_Jaw, Value = 20.75 P2 = Upper_Module, Value = 20.65 P3 = Ambient, Value = 20.46 14:40:33 Integrated Voltage Measurement... 14:41:16 Voltage Offset Correction: v_off_ini = -0.000001078 V, v_off_fin = 0.000001019 V 14:41:16 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.143474175 Vs 14:41:16 Integrated Voltage Measurement... 14:41:55 Voltage Offset Correction: v_off_ini = 0.000000522 V, v_off_fin = -0.000001233 V 14:41:55 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143461097 Vs 14:41:56 8\ Voltage Measurement, V = 0.000000 V 14:41:56 Temperature Measurement, Probe Number = 0, T = 20.746000 C 14:41:57 Temperature Measurement, Probe Number = 1, T = 20.648000 C 14:41:58 Temperature Measurement, Probe Number = 2, T = 20.463000 C 14:41:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Lower_Jaw, Value = 20.75 P2 = Upper_Module, Value = 20.65 P3 = Ambient, Value = 20.46 14:41:58 Integrated Voltage Measurement... 14:42:38 Voltage Offset Correction: v_off_ini = -0.000000657 V, v_off_fin = 0.000000874 V 14:42:38 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143478259 Vs 14:42:38 Integrated Voltage Measurement... 14:43:11 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = -0.000002160 V 14:43:11 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143456537 Vs 14:43:12 8\ Voltage Measurement, V = 0.000000 V 14:43:12 Temperature Measurement, Probe Number = 0, T = 20.746000 C 14:43:13 Temperature Measurement, Probe Number = 1, T = 20.650000 C 14:43:13 Temperature Measurement, Probe Number = 2, T = 20.442000 C 14:43:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Lower_Jaw, Value = 20.75 P2 = Upper_Module, Value = 20.65 P3 = Ambient, Value = 20.44 14:43:13 Integrated Voltage Measurement... 14:43:49 Voltage Offset Correction: v_off_ini = -0.000000573 V, v_off_fin = 0.000000792 V 14:43:49 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143482788 Vs 14:43:49 Integrated Voltage Measurement... 14:45:11 Voltage Offset Correction: v_off_ini = 0.000000958 V, v_off_fin = -0.000001500 V 14:45:11 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143453009 Vs 14:45:12 8\ Voltage Measurement, V = 0.000000 V 14:45:13 Temperature Measurement, Probe Number = 0, T = 20.747000 C 14:45:13 Temperature Measurement, Probe Number = 1, T = 20.649000 C 14:45:14 Temperature Measurement, Probe Number = 2, T = 20.434000 C 14:45:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Lower_Jaw, Value = 20.75 P2 = Upper_Module, Value = 20.65 P3 = Ambient, Value = 20.43 14:45:14 Integrated Voltage Measurement... 14:45:45 Voltage Offset Correction: v_off_ini = -0.000000872 V, v_off_fin = 0.000001071 V 14:45:45 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143477515 Vs 14:45:45 Integrated Voltage Measurement... 14:46:19 Voltage Offset Correction: v_off_ini = 0.000001066 V, v_off_fin = -0.000000769 V 14:46:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.143462033 Vs 14:46:20 8\ Voltage Measurement, V = 0.000000 V 14:46:20 Temperature Measurement, Probe Number = 0, T = 20.746000 C 14:46:21 Temperature Measurement, Probe Number = 1, T = 20.652000 C 14:46:21 Temperature Measurement, Probe Number = 2, T = 20.466000 C 14:46:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Lower_Jaw, Value = 20.75 P2 = Upper_Module, Value = 20.65 P3 = Ambient, Value = 20.47 14:46:21 Integrated Voltage Measurement... 14:46:58 Voltage Offset Correction: v_off_ini = -0.000000704 V, v_off_fin = 0.000001923 V 14:46:58 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143478268 Vs 14:46:58 Integrated Voltage Measurement... 14:47:32 Voltage Offset Correction: v_off_ini = 0.000000796 V, v_off_fin = -0.000002322 V 14:47:32 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143450409 Vs 14:47:33 8\ Voltage Measurement, V = 0.000000 V 14:47:33 Temperature Measurement, Probe Number = 0, T = 20.748000 C 14:47:34 Temperature Measurement, Probe Number = 1, T = 20.649000 C 14:47:34 Temperature Measurement, Probe Number = 2, T = 20.477000 C 14:47:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Lower_Jaw, Value = 20.75 P2 = Upper_Module, Value = 20.65 P3 = Ambient, Value = 20.48 14:47:34 Integrated Voltage Measurement... 14:48:09 Voltage Offset Correction: v_off_ini = -0.000000796 V, v_off_fin = 0.000001129 V 14:48:09 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143472268 Vs 14:48:09 Integrated Voltage Measurement... 14:48:47 Voltage Offset Correction: v_off_ini = 0.000000747 V, v_off_fin = -0.000001301 V 14:48:47 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143458580 Vs 14:48:48 8\ Voltage Measurement, V = 0.000000 V 14:48:48 Temperature Measurement, Probe Number = 0, T = 20.749000 C 14:48:49 Temperature Measurement, Probe Number = 1, T = 20.650000 C 14:48:50 Temperature Measurement, Probe Number = 2, T = 20.469000 C 14:48:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Lower_Jaw, Value = 20.75 P2 = Upper_Module, Value = 20.65 P3 = Ambient, Value = 20.47 14:48:50 Integrated Voltage Measurement... 14:49:23 Voltage Offset Correction: v_off_ini = -0.000000452 V, v_off_fin = 0.000000020 V 14:49:23 Integrated Voltage Measurement Delta Gap = -0.0000001 m VT = -0.000000420 Vs 14:49:23 Integrated Voltage Measurement... 14:49:49 Voltage Offset Correction: v_off_ini = 0.000000007 V, v_off_fin = -0.000000054 V 14:49:49 Integrated Voltage Measurement Delta Gap = -0.0000001 m VT = -0.000000129 Vs 14:49:50 8\ Voltage Measurement, V = 0.000000 V 14:49:50 Temperature Measurement, Probe Number = 0, T = 20.749000 C 14:49:51 Temperature Measurement, Probe Number = 1, T = 20.651000 C 14:49:52 Temperature Measurement, Probe Number = 2, T = 20.463000 C 14:49:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Lower_Jaw, Value = 20.75 P2 = Upper_Module, Value = 20.65 P3 = Ambient, Value = 20.46 14:49:52 Integrated Voltage Measurement... 14:50:21 Voltage Offset Correction: v_off_ini = -0.000000130 V, v_off_fin = 0.000001184 V 14:50:21 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.143492905 Vs 14:50:21 Integrated Voltage Measurement... 14:50:55 Voltage Offset Correction: v_off_ini = 0.000000510 V, v_off_fin = -0.000001995 V 14:50:55 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.143467052 Vs 14:50:56 8\ Voltage Measurement, V = 0.000000 V 14:50:57 Temperature Measurement, Probe Number = 0, T = 20.749000 C 14:50:57 Temperature Measurement, Probe Number = 1, T = 20.648000 C 14:50:58 Temperature Measurement, Probe Number = 2, T = 20.473000 C 14:50:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Lower_Jaw, Value = 20.75 P2 = Upper_Module, Value = 20.65 P3 = Ambient, Value = 20.47 14:50:58 Integrated Voltage Measurement... 14:51:32 Voltage Offset Correction: v_off_ini = -0.000000689 V, v_off_fin = 0.000001842 V 14:51:32 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.143472844 Vs 14:51:32 Integrated Voltage Measurement... 14:52:13 Voltage Offset Correction: v_off_ini = 0.000000520 V, v_off_fin = -0.000001898 V 14:52:13 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.143464618 Vs 14:52:14 8\ Voltage Measurement, V = 0.000000 V 14:52:14 Temperature Measurement, Probe Number = 0, T = 20.750000 C 14:52:15 Temperature Measurement, Probe Number = 1, T = 20.650000 C 14:52:16 Temperature Measurement, Probe Number = 2, T = 20.457000 C 14:52:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Lower_Jaw, Value = 20.75 P2 = Upper_Module, Value = 20.65 P3 = Ambient, Value = 20.46 14:52:16 Integrated Voltage Measurement... 14:52:49 Voltage Offset Correction: v_off_ini = -0.000000809 V, v_off_fin = 0.000001269 V 14:52:49 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143475973 Vs 14:52:49 Integrated Voltage Measurement... 14:53:24 Voltage Offset Correction: v_off_ini = 0.000000775 V, v_off_fin = -0.000001302 V 14:53:24 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.143457467 Vs