SLAC Magnetic Measurements Date: 09-09-2020 Time: 21:37:42 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_003_Cell_34_Upstairs Serial Number: PC97084 Run Number: 1 Measurement Device: WalkerVS Operator: sda Comment: Coil Integral measurement upstairs, cable straight into 3458A. Set 1 21:37:44 Ambient Measurement Device(s) Being Used, type = None 21:37:44 Magnet Voltage Measurement Device(s) Being Used, type = None 21:37:45 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 21:37:45 XMAG Device(s) Being Used, type = None 21:37:45 Ambient Measurement Device(s) Being Used, type = None 21:37:49   Voltage Measurement, V = 0.000000 V 21:37:49 Temperature Measurement, Probe Number = 0, T = 23.383000 C 21:37:50 Temperature Measurement, Probe Number = 1, T = 24.175000 C 21:37:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.38 P2 = 3458_Meas_Junction, Value = 24.18 21:37:50 Integrated Voltage Measurement... 21:38:23 Voltage Offset Correction: v_off_ini = -0.000002464 V, v_off_fin = -0.000002486 V 21:38:23 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = -0.142294973 Vs 21:38:23 Integrated Voltage Measurement... 21:38:58 Voltage Offset Correction: v_off_ini = -0.000002679 V, v_off_fin = -0.000002526 V 21:38:58 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.142263858 Vs 21:38:59   Voltage Measurement, V = 0.000000 V 21:39:00 Temperature Measurement, Probe Number = 0, T = 23.385000 C 21:39:01 Temperature Measurement, Probe Number = 1, T = 24.134000 C 21:39:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.39 P2 = 3458_Meas_Junction, Value = 24.13 21:39:01 Integrated Voltage Measurement... 21:39:43 Voltage Offset Correction: v_off_ini = -0.000002214 V, v_off_fin = -0.000003134 V 21:39:43 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = -0.142298332 Vs 21:39:43 Integrated Voltage Measurement... 21:40:17 Voltage Offset Correction: v_off_ini = -0.000002744 V, v_off_fin = -0.000001983 V 21:40:17 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = 0.142269622 Vs 21:40:18   Voltage Measurement, V = 0.000000 V 21:40:19 Temperature Measurement, Probe Number = 0, T = 23.394000 C 21:40:19 Temperature Measurement, Probe Number = 1, T = 24.132000 C 21:40:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.39 P2 = 3458_Meas_Junction, Value = 24.13 21:40:19 Integrated Voltage Measurement... 21:41:00 Voltage Offset Correction: v_off_ini = -0.000002301 V, v_off_fin = -0.000002177 V 21:41:00 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = -0.142305757 Vs 21:41:00 Integrated Voltage Measurement... 21:41:32 Voltage Offset Correction: v_off_ini = -0.000002972 V, v_off_fin = -0.000003142 V 21:41:32 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = 0.142273163 Vs 21:41:33   Voltage Measurement, V = 0.000000 V 21:41:33 Temperature Measurement, Probe Number = 0, T = 23.401000 C 21:41:34 Temperature Measurement, Probe Number = 1, T = 24.145000 C 21:41:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.40 P2 = 3458_Meas_Junction, Value = 24.14 21:41:34 Integrated Voltage Measurement... 21:42:13 Voltage Offset Correction: v_off_ini = -0.000002343 V, v_off_fin = -0.000002603 V 21:42:13 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = -0.142298649 Vs 21:42:13 Integrated Voltage Measurement... 21:42:46 Voltage Offset Correction: v_off_ini = -0.000002742 V, v_off_fin = -0.000000498 V 21:42:46 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.142266689 Vs 21:42:47   Voltage Measurement, V = 0.000000 V 21:42:48 Temperature Measurement, Probe Number = 0, T = 23.413000 C 21:42:49 Temperature Measurement, Probe Number = 1, T = 24.166000 C 21:42:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.41 P2 = 3458_Meas_Junction, Value = 24.17 21:42:49 Integrated Voltage Measurement... 21:43:29 Voltage Offset Correction: v_off_ini = -0.000002239 V, v_off_fin = -0.000002198 V 21:43:29 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = -0.142298042 Vs 21:43:29 Integrated Voltage Measurement... 21:44:08 Voltage Offset Correction: v_off_ini = -0.000002777 V, v_off_fin = -0.000002451 V 21:44:08 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.142270347 Vs 21:44:09   Voltage Measurement, V = 0.000000 V 21:44:10 Temperature Measurement, Probe Number = 0, T = 23.418000 C 21:44:10 Temperature Measurement, Probe Number = 1, T = 24.175000 C 21:44:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.42 P2 = 3458_Meas_Junction, Value = 24.18 21:44:10 Integrated Voltage Measurement... 21:44:44 Voltage Offset Correction: v_off_ini = -0.000002014 V, v_off_fin = -0.000003541 V 21:44:44 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = -0.142293581 Vs 21:44:44 Integrated Voltage Measurement... 21:45:19 Voltage Offset Correction: v_off_ini = -0.000002817 V, v_off_fin = -0.000001614 V 21:45:19 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = 0.142284005 Vs 21:45:20   Voltage Measurement, V = 0.000000 V 21:45:21 Temperature Measurement, Probe Number = 0, T = 23.432000 C 21:45:21 Temperature Measurement, Probe Number = 1, T = 24.196000 C 21:45:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.43 P2 = 3458_Meas_Junction, Value = 24.20 21:45:21 Integrated Voltage Measurement... 21:45:53 Voltage Offset Correction: v_off_ini = -0.000002009 V, v_off_fin = -0.000001954 V 21:45:53 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = -0.142310500 Vs 21:45:53 Integrated Voltage Measurement... 21:46:25 Voltage Offset Correction: v_off_ini = -0.000002898 V, v_off_fin = -0.000001779 V 21:46:25 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.142284410 Vs 21:46:26   Voltage Measurement, V = 0.000000 V 21:46:26 Temperature Measurement, Probe Number = 0, T = 23.438000 C 21:46:27 Temperature Measurement, Probe Number = 1, T = 24.197000 C 21:46:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.44 P2 = 3458_Meas_Junction, Value = 24.20 21:46:27 Integrated Voltage Measurement... 21:46:57 Voltage Offset Correction: v_off_ini = -0.000002155 V, v_off_fin = -0.000002426 V 21:46:58 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = -0.142293584 Vs 21:46:58 Integrated Voltage Measurement... 21:47:29 Voltage Offset Correction: v_off_ini = -0.000002756 V, v_off_fin = -0.000002108 V 21:47:29 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = 0.142277023 Vs 21:47:30   Voltage Measurement, V = 0.000000 V 21:47:30 Temperature Measurement, Probe Number = 0, T = 23.442000 C 21:47:31 Temperature Measurement, Probe Number = 1, T = 24.211000 C 21:47:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.44 P2 = 3458_Meas_Junction, Value = 24.21 21:47:31 Integrated Voltage Measurement... 21:48:03 Voltage Offset Correction: v_off_ini = -0.000002044 V, v_off_fin = -0.000002177 V 21:48:03 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = -0.142311194 Vs 21:48:03 Integrated Voltage Measurement... 21:48:34 Voltage Offset Correction: v_off_ini = -0.000002862 V, v_off_fin = -0.000001667 V 21:48:34 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = 0.142271090 Vs 21:48:35   Voltage Measurement, V = 0.000000 V 21:48:36 Temperature Measurement, Probe Number = 0, T = 23.447000 C 21:48:36 Temperature Measurement, Probe Number = 1, T = 24.231000 C 21:48:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.45 P2 = 3458_Meas_Junction, Value = 24.23 21:48:36 Integrated Voltage Measurement... 21:49:08 Voltage Offset Correction: v_off_ini = -0.000002008 V, v_off_fin = -0.000002957 V 21:49:08 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = -0.142316807 Vs 21:49:08 Integrated Voltage Measurement... 21:49:41 Voltage Offset Correction: v_off_ini = -0.000002835 V, v_off_fin = -0.000000958 V 21:49:41 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = 0.142277123 Vs