SLAC Magnetic Measurements Date: 12-02-2020 Time: 14:20:37 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_003_Cell_34 Serial Number: PC33408 Run Number: 14 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full set 14 14:20:55 Ambient Measurement Device(s) Being Used, type = None 14:20:55 Magnet Voltage Measurement Device(s) Being Used, type = None 14:20:56 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 14:20:56 XMAG Device(s) Being Used, type = None 14:20:56 Ambient Measurement Device(s) Being Used, type = None 14:20:59   Voltage Measurement, V = 0.000000 V 14:21:00 Temperature Measurement, Probe Number = 0, T = 21.037000 C 14:21:01 Temperature Measurement, Probe Number = 1, T = 22.630000 C 14:21:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.04 P2 = 3458_Meas_Junction, Value = 22.63 14:21:01 Integrated Voltage Measurement... 14:21:29 Voltage Offset Correction: v_off_ini = 0.000000731 V, v_off_fin = 0.000001395 V 14:21:29 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142253937 Vs 14:21:29 Integrated Voltage Measurement... 14:22:00 Voltage Offset Correction: v_off_ini = 0.000000841 V, v_off_fin = -0.000001787 V 14:22:00 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142289184 Vs 14:22:01   Voltage Measurement, V = 0.000000 V 14:22:02 Temperature Measurement, Probe Number = 0, T = 21.026000 C 14:22:02 Temperature Measurement, Probe Number = 1, T = 22.579000 C 14:22:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.03 P2 = 3458_Meas_Junction, Value = 22.58 14:22:02 Integrated Voltage Measurement... 14:22:34 Voltage Offset Correction: v_off_ini = -0.000001923 V, v_off_fin = 0.000001132 V 14:22:34 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.142269494 Vs 14:22:34 Integrated Voltage Measurement... 14:23:04 Voltage Offset Correction: v_off_ini = 0.000000599 V, v_off_fin = 0.000000034 V 14:23:04 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142286919 Vs 14:23:05   Voltage Measurement, V = 0.000000 V 14:23:06 Temperature Measurement, Probe Number = 0, T = 21.027000 C 14:23:06 Temperature Measurement, Probe Number = 1, T = 22.560000 C 14:23:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.03 P2 = 3458_Meas_Junction, Value = 22.56 14:23:06 Integrated Voltage Measurement... 14:23:37 Voltage Offset Correction: v_off_ini = -0.000000082 V, v_off_fin = 0.000001108 V 14:23:37 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.142292626 Vs 14:23:37 Integrated Voltage Measurement... 14:24:09 Voltage Offset Correction: v_off_ini = 0.000000617 V, v_off_fin = -0.000001789 V 14:24:09 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142258317 Vs 14:24:10   Voltage Measurement, V = 0.000000 V 14:24:11 Temperature Measurement, Probe Number = 0, T = 21.020000 C 14:24:11 Temperature Measurement, Probe Number = 1, T = 22.614000 C 14:24:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.02 P2 = 3458_Meas_Junction, Value = 22.61 14:24:11 Integrated Voltage Measurement... 14:24:42 Voltage Offset Correction: v_off_ini = 0.000000097 V, v_off_fin = 0.000001017 V 14:24:42 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.142280264 Vs 14:24:42 Integrated Voltage Measurement... 14:25:13 Voltage Offset Correction: v_off_ini = 0.000000534 V, v_off_fin = -0.000000390 V 14:25:13 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142270127 Vs 14:25:14   Voltage Measurement, V = 0.000000 V 14:25:15 Temperature Measurement, Probe Number = 0, T = 21.002000 C 14:25:15 Temperature Measurement, Probe Number = 1, T = 22.657000 C 14:25:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.00 P2 = 3458_Meas_Junction, Value = 22.66 14:25:15 Integrated Voltage Measurement... 14:25:47 Voltage Offset Correction: v_off_ini = 0.000000297 V, v_off_fin = 0.000001284 V 14:25:47 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.142293872 Vs 14:25:47 Integrated Voltage Measurement... 14:26:20 Voltage Offset Correction: v_off_ini = 0.000000562 V, v_off_fin = -0.000000637 V 14:26:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142262041 Vs 14:26:21   Voltage Measurement, V = 0.000000 V 14:26:21 Temperature Measurement, Probe Number = 0, T = 20.986000 C 14:26:22 Temperature Measurement, Probe Number = 1, T = 22.672000 C 14:26:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.99 P2 = 3458_Meas_Junction, Value = 22.67 14:26:22 Integrated Voltage Measurement... 14:26:52 Voltage Offset Correction: v_off_ini = 0.000000043 V, v_off_fin = 0.000000224 V 14:26:52 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = 0.142281826 Vs 14:26:52 Integrated Voltage Measurement... 14:27:23 Voltage Offset Correction: v_off_ini = 0.000000496 V, v_off_fin = -0.000002035 V 14:27:23 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142296593 Vs 14:27:24   Voltage Measurement, V = 0.000000 V 14:27:25 Temperature Measurement, Probe Number = 0, T = 20.974000 C 14:27:25 Temperature Measurement, Probe Number = 1, T = 22.690000 C 14:27:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.97 P2 = 3458_Meas_Junction, Value = 22.69 14:27:25 Integrated Voltage Measurement... 14:28:08 Voltage Offset Correction: v_off_ini = -0.000000137 V, v_off_fin = -0.000001629 V 14:28:08 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142318126 Vs 14:28:08 Integrated Voltage Measurement... 14:28:44 Voltage Offset Correction: v_off_ini = 0.000000617 V, v_off_fin = -0.000000822 V 14:28:44 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.142269310 Vs 14:28:45   Voltage Measurement, V = 0.000000 V 14:28:45 Temperature Measurement, Probe Number = 0, T = 20.967000 C 14:28:46 Temperature Measurement, Probe Number = 1, T = 22.707000 C 14:28:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.97 P2 = 3458_Meas_Junction, Value = 22.71 14:28:46 Integrated Voltage Measurement... 14:29:18 Voltage Offset Correction: v_off_ini = 0.000000040 V, v_off_fin = 0.000000654 V 14:29:18 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.142290437 Vs 14:29:18 Integrated Voltage Measurement... 14:29:53 Voltage Offset Correction: v_off_ini = 0.000000692 V, v_off_fin = 0.000001170 V 14:29:53 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.142271723 Vs 14:29:54   Voltage Measurement, V = 0.000000 V 14:29:55 Temperature Measurement, Probe Number = 0, T = 20.959000 C 14:29:56 Temperature Measurement, Probe Number = 1, T = 22.709000 C 14:29:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.96 P2 = 3458_Meas_Junction, Value = 22.71 14:29:56 Integrated Voltage Measurement... 14:30:28 Voltage Offset Correction: v_off_ini = 0.000000196 V, v_off_fin = 0.000000262 V 14:30:28 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = 0.142276703 Vs 14:30:29 Integrated Voltage Measurement... 14:30:59 Voltage Offset Correction: v_off_ini = 0.000000547 V, v_off_fin = -0.000005040 V 14:30:59 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142208409 Vs 14:31:00   Voltage Measurement, V = 0.000000 V 14:31:01 Temperature Measurement, Probe Number = 0, T = 20.950000 C 14:31:02 Temperature Measurement, Probe Number = 1, T = 22.722000 C 14:31:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.95 P2 = 3458_Meas_Junction, Value = 22.72 14:31:02 Integrated Voltage Measurement... 14:31:33 Voltage Offset Correction: v_off_ini = 0.000000218 V, v_off_fin = -0.000004165 V 14:31:34 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.142244307 Vs 14:31:34 Integrated Voltage Measurement... 14:32:11 Voltage Offset Correction: v_off_ini = 0.000001220 V, v_off_fin = 0.000001517 V 14:32:11 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.142231885 Vs