SLAC Magnetic Measurements Date: 10-29-2020 Time: 13:59:37 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_003_Cell_34 Serial Number: PC33408 Run Number: 12 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 12 13:59:55 Ambient Measurement Device(s) Being Used, type = None 13:59:55 Magnet Voltage Measurement Device(s) Being Used, type = None 13:59:55 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 13:59:55 XMAG Device(s) Being Used, type = None 13:59:55 Ambient Measurement Device(s) Being Used, type = None 13:59:58   Voltage Measurement, V = 0.000000 V 13:59:59 Temperature Measurement, Probe Number = 0, T = 21.054000 C 14:00:00 Temperature Measurement, Probe Number = 1, T = 21.856000 C 14:00:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.05 P2 = 3458_Meas_Junction, Value = 21.86 14:00:00 Integrated Voltage Measurement... 14:00:26 Voltage Offset Correction: v_off_ini = 0.000000554 V, v_off_fin = 0.000001762 V 14:00:26 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142332045 Vs 14:00:26 Integrated Voltage Measurement... 14:00:57 Voltage Offset Correction: v_off_ini = 0.000000748 V, v_off_fin = -0.000000629 V 14:00:57 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142320855 Vs 14:00:58   Voltage Measurement, V = 0.000000 V 14:00:58 Temperature Measurement, Probe Number = 0, T = 21.054000 C 14:00:59 Temperature Measurement, Probe Number = 1, T = 21.863000 C 14:00:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.05 P2 = 3458_Meas_Junction, Value = 21.86 14:00:59 Integrated Voltage Measurement... 14:01:31 Voltage Offset Correction: v_off_ini = 0.000000059 V, v_off_fin = 0.000000537 V 14:01:31 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.142324360 Vs 14:01:31 Integrated Voltage Measurement... 14:02:02 Voltage Offset Correction: v_off_ini = 0.000000402 V, v_off_fin = -0.000000758 V 14:02:02 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.142311690 Vs 14:02:03   Voltage Measurement, V = 0.000000 V 14:02:03 Temperature Measurement, Probe Number = 0, T = 21.068000 C 14:02:04 Temperature Measurement, Probe Number = 1, T = 21.870000 C 14:02:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.07 P2 = 3458_Meas_Junction, Value = 21.87 14:02:04 Integrated Voltage Measurement... 14:02:35 Voltage Offset Correction: v_off_ini = -0.000000308 V, v_off_fin = 0.000001425 V 14:02:35 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.142328064 Vs 14:02:35 Integrated Voltage Measurement... 14:03:13 Voltage Offset Correction: v_off_ini = 0.000000322 V, v_off_fin = -0.000001504 V 14:03:13 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142307396 Vs 14:03:14   Voltage Measurement, V = 0.000000 V 14:03:15 Temperature Measurement, Probe Number = 0, T = 21.080000 C 14:03:15 Temperature Measurement, Probe Number = 1, T = 21.889000 C 14:03:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.08 P2 = 3458_Meas_Junction, Value = 21.89 14:03:15 Integrated Voltage Measurement... 14:03:47 Voltage Offset Correction: v_off_ini = -0.000000242 V, v_off_fin = 0.000000083 V 14:03:47 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.142329316 Vs 14:03:47 Integrated Voltage Measurement... 14:04:19 Voltage Offset Correction: v_off_ini = 0.000000405 V, v_off_fin = -0.000000800 V 14:04:19 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142321422 Vs 14:04:20   Voltage Measurement, V = 0.000000 V 14:04:20 Temperature Measurement, Probe Number = 0, T = 21.085000 C 14:04:21 Temperature Measurement, Probe Number = 1, T = 21.895000 C 14:04:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.09 P2 = 3458_Meas_Junction, Value = 21.89 14:04:21 Integrated Voltage Measurement... 14:04:53 Voltage Offset Correction: v_off_ini = -0.000000307 V, v_off_fin = -0.000000455 V 14:04:53 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142339136 Vs 14:04:53 Integrated Voltage Measurement... 14:05:24 Voltage Offset Correction: v_off_ini = 0.000000519 V, v_off_fin = -0.000001421 V 14:05:24 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142316669 Vs 14:05:25   Voltage Measurement, V = 0.000000 V 14:05:26 Temperature Measurement, Probe Number = 0, T = 21.083000 C 14:05:27 Temperature Measurement, Probe Number = 1, T = 21.903000 C 14:05:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.08 P2 = 3458_Meas_Junction, Value = 21.90 14:05:27 Integrated Voltage Measurement... 14:05:59 Voltage Offset Correction: v_off_ini = -0.000000375 V, v_off_fin = 0.000000171 V 14:05:59 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142344946 Vs 14:05:59 Integrated Voltage Measurement... 14:06:31 Voltage Offset Correction: v_off_ini = 0.000000358 V, v_off_fin = -0.000000973 V 14:06:31 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142293604 Vs 14:06:32   Voltage Measurement, V = 0.000000 V 14:06:33 Temperature Measurement, Probe Number = 0, T = 21.087000 C 14:06:33 Temperature Measurement, Probe Number = 1, T = 21.918000 C 14:06:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.09 P2 = 3458_Meas_Junction, Value = 21.92 14:06:33 Integrated Voltage Measurement... 14:07:04 Voltage Offset Correction: v_off_ini = -0.000000380 V, v_off_fin = 0.000000482 V 14:07:04 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.142311836 Vs 14:07:04 Integrated Voltage Measurement... 14:07:34 Voltage Offset Correction: v_off_ini = 0.000000551 V, v_off_fin = -0.000001494 V 14:07:34 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142304379 Vs 14:07:35   Voltage Measurement, V = 0.000000 V 14:07:36 Temperature Measurement, Probe Number = 0, T = 21.097000 C 14:07:37 Temperature Measurement, Probe Number = 1, T = 21.918000 C 14:07:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.10 P2 = 3458_Meas_Junction, Value = 21.92 14:07:37 Integrated Voltage Measurement... 14:08:08 Voltage Offset Correction: v_off_ini = -0.000000235 V, v_off_fin = 0.000001783 V 14:08:08 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142337749 Vs 14:08:08 Integrated Voltage Measurement... 14:08:39 Voltage Offset Correction: v_off_ini = 0.000000185 V, v_off_fin = -0.000000345 V 14:08:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142298779 Vs 14:08:40   Voltage Measurement, V = 0.000000 V 14:08:41 Temperature Measurement, Probe Number = 0, T = 21.105000 C 14:08:41 Temperature Measurement, Probe Number = 1, T = 21.923000 C 14:08:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.11 P2 = 3458_Meas_Junction, Value = 21.92 14:08:41 Integrated Voltage Measurement... 14:09:12 Voltage Offset Correction: v_off_ini = -0.000000188 V, v_off_fin = 0.000000968 V 14:09:12 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.142313131 Vs 14:09:12 Integrated Voltage Measurement... 14:09:43 Voltage Offset Correction: v_off_ini = 0.000000425 V, v_off_fin = -0.000000806 V 14:09:44 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142307637 Vs 14:09:44   Voltage Measurement, V = 0.000000 V 14:09:45 Temperature Measurement, Probe Number = 0, T = 21.118000 C 14:09:46 Temperature Measurement, Probe Number = 1, T = 21.914000 C 14:09:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.12 P2 = 3458_Meas_Junction, Value = 21.91 14:09:46 Integrated Voltage Measurement... 14:10:18 Voltage Offset Correction: v_off_ini = -0.000000173 V, v_off_fin = 0.000000769 V 14:10:18 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142336279 Vs 14:10:18 Integrated Voltage Measurement... 14:10:50 Voltage Offset Correction: v_off_ini = 0.000000571 V, v_off_fin = -0.000001435 V 14:10:50 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142304657 Vs